We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
KMC CONTROLS Reset Volume Controller: 2000 Series - Reset Volume Controls
KMC CONTROLSReset Volume Controls

KMC CONTROLS Reset Volume Controller: 2000 Series

The KMC CONTROLS Reset Volume Controller: 2000 Series (MPN CSC-2009) is a direct-acting, normally open reset volume control. It features a minimum setpoint range of 0 to 2 in wc and a maximum setpoint range of Min +…

SKU 3G-OTH-70460

Brand
KMC CONTROLS
Item
Reset Volume Controller: 2000 Series
Category
Reset Volume Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

KMC CONTROLS
Brand
KMC CONTROLS
Maximum Setpoint Range
Min + 2 in wc
Minimum Setpoint Range
0 to 2 in wc
Reset Start Point Range
8 to 13 psi
Manufacturer Part Number
CSC-2009
Thermostat Required for Cooling
Direct Acting
Thermostat Required for Heating
Reverse Acting
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KMC CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KMC CONTROLS Reset Volume Controller: 2000 Series (MPN CSC-2009) is a direct-acting, normally open reset volume control. It features a minimum setpoint range of 0 to 2 in wc and a maximum setpoint range of Min + 2 in wc, with a reset start point range of 8 to 13 psi. This controller requires a direct-acting thermostat for cooling and a reverse-acting thermostat for heating.

Used in

Common applications for KMC CONTROLS
HVAC building automation — KMC Controls BAC-4202CW0001 BACnet MS/TP controller for fan coil unit control in commercial buildings
Outdoor damper actuation — KMC Controls HCO-1152 weather shield enclosure with MEP-455xxx series actuator for rooftop air handling units
Temperature monitoring in industrial spaces — KMC Controls STE-6011-10 wall-mount room temperature sensor for duct or wall installation in factories
Pneumatic damper control in retrofit projects — KMC Controls MCP-36318000 rotary pneumatic actuator for existing HVAC systems with 3-8 psi spring range
VAV box upgrade for energy efficiency — KMC Controls KIT-1002 VAV control kit with universal thermostat upgrade for pneumatic boxes with electric reheat
RTU control with occupancy sensing — KMC Controls BAC-4203CW0002 BACnet MS/TP controller for rooftop units with onboard occupancy sensor in office buildings

KMC CONTROLS Products

3G Electric supplies KMC CONTROLS reset volume controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3021-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
KMC CONTROLS
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3021-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
VAV Control Kit: Pneumatic VAV Box, Electric Reheat (MPN KIT-1002). Key specifications — Brand: KMC CONTROLS; Manufacturer Part Number: KIT-1002; Includes: Universal Thermostat Upgrade Kit.
KMC CONTROLS
VAV Control Kit: Pneumatic VAV Box, Electric Reheat (MPN KIT-1002). Key specifications — Brand: KMC CONTROLS; Manufacturer Part Number: KIT-1002; Includes: Universal Thermostat Upgrade Kit.
Pneumatic Damper Actuator: Rotary, 3 psi to 8 psi Spring Range, Round Shaft Mounting, 100° Rotation (MPN MCP-36318000). Key specifications — Actuator Connection: Bracket; Brand: KMC CONTROLS; Positioner Included: No; For Fire/Smoke Applications: No.
KMC CONTROLS
Pneumatic Damper Actuator: Rotary, 3 psi to 8 psi Spring Range, Round Shaft Mounting, 100° Rotation (MPN MCP-36318000). Key specifications — Actuator Connection: Bracket; Brand: KMC CONTROLS; Positioner Included: No; For Fire/Smoke Applications: No.
Pneumatic Receiver Controller: Dual Input, 3 psi to 15 psi Signal, 30 psi Supply, Proportional (MPN CCC-1002). Key specifications — Brand: KMC CONTROLS; Control Action: Direct Acting/Reverse Acting; Control Signal: Proportional.
KMC CONTROLS
Pneumatic Receiver Controller: Dual Input, 3 psi to 15 psi Signal, 30 psi Supply, Proportional (MPN CCC-1002). Key specifications — Brand: KMC CONTROLS; Control Action: Direct Acting/Reverse Acting; Control Signal: Proportional.
Differential Pressure Control: SPDT, Open/Close on Rise and Fall, 208V/240V, Auto Reset, 3.5 psi (MPN P74EA-8C). Key specifications — Rated Voltage: 240V; Switch Action: Open/Close on Rise and Fall; Reset Type: Automatic; Brand: JOHNSON CONTROLS.
JOHNSON CONTROLS
Differential Pressure Control: SPDT, Open/Close on Rise and Fall, 208V/240V, Auto Reset, 3.5 psi (MPN P74EA-8C). Key specifications — Rated Voltage: 240V; Switch Action: Open/Close on Rise and Fall; Reset Type: Automatic; Brand: JOHNSON CONTROLS.
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C). Key specifications — Brand: JOHNSON CONTROLS; Manufacturer Part Number: P170AB-12C; Contact Form: SPST; Rated Voltage: 120V AC; Switch Action: Open on Fall.
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P170AB-12C). Key specifications — Brand: JOHNSON CONTROLS; Manufacturer Part Number: P170AB-12C; Contact Form: SPST; Rated Voltage: 120V AC; Switch Action: Open on Fall.

More from KMC CONTROLS

View all KMC CONTROLS parts
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi (MPN CSC-2004). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Reverse Acting; Thermostat Required for Heating: Direct Acting; Brand: KMC CONTROLS; Reset Start Point Range: 3 to 8 psi.
KMC CONTROLS
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi (MPN CSC-2004). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Reverse Acting; Thermostat Required for Heating: Direct Acting; Brand: KMC CONTROLS; Reset Start Point Range: 3 to 8 psi.
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi (MPN CSC-2008). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Reverse Acting; Thermostat Required for Heating: Direct Acting; Brand: KMC CONTROLS; Reset Start Point Range: 3 to 8 psi.
KMC CONTROLS
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi (MPN CSC-2008). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Reverse Acting; Thermostat Required for Heating: Direct Acting; Brand: KMC CONTROLS; Reset Start Point Range: 3 to 8 psi.
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3011-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
KMC CONTROLS
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3011-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2001). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.
KMC CONTROLS
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2001). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3023-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
KMC CONTROLS
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3023-10). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min to 1 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3025-10). Key specifications — Minimum Setpoint Range: 0 to 2 in wc; Maximum Setpoint Range: Min to 2 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
KMC CONTROLS
Reset Volume Controller: 3000 Series, Direct/Reverse Acting, Normally Open or Normally Closed (MPN CSC-3025-10). Key specifications — Minimum Setpoint Range: 0 to 2 in wc; Maximum Setpoint Range: Min to 2 in wc; Thermostat Required for Cooling: Direct/Reverse Acting; Thermostat Required for Heating: Direct/Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 0 to 10 psi.
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2007). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.
KMC CONTROLS
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2007). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2003). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.
KMC CONTROLS
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point (MPN CSC-2003). Key specifications — Minimum Setpoint Range: 0 to 1 in wc; Maximum Setpoint Range: Min + 1 in wc; Thermostat Required for Cooling: Direct Acting; Thermostat Required for Heating: Reverse Acting; Brand: KMC CONTROLS; Reset Start Point Range: 8 to 13 psi.