We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
BYK GARDNER logo

BYK GARDNER

BYK Gardner is a manufacturer of physical testing instruments for quality control in coatings, paints, inks, adhesives, and related liquid materials. The brand, part of the BYK-Chemie GmbH group, has a history dating back to the early 20th century and is recognized for its precision measurement tools used in laboratory and production environments. Primary product families include viscosity cups (such as Ford-style and flow cups), film applicators, gloss meters, color measurement devices, and other physical property testers. These instruments are designed to meet standardized test methods like ASTM D1200, ISO 2431, and others, ensuring repeatable and comparable results across different facilities. BYK Gardner viscosity cups, for example, are available in various orifice sizes to cover a range of viscosity from low to high (e.g., 25 cSt to 370 cSt), and many models come with NIST-traceable certificates for calibration assurance. The cups are typically made from corrosion-resistant materials such as anodized aluminum or stainless steel, with precision-machined orifices to maintain accuracy. Accessories like cup stands and flow cups complement the main product line, enabling consistent testing setups. 3G Electric supplies a selection of BYK Gardner viscosity cups and viscometer accessories, including Ford-style cups with different viscosity ranges and standard position stands. These items are available for global shipment, with logistics support to handle procurement for plant engineers, maintenance managers, and quality control specialists. The product range supports applications in paint manufacturing, ink production, adhesive formulation, and other industries where liquid viscosity is a critical parameter. By offering multiple SKUs with varying specifications, 3G Electric enables buyers to select the appropriate instrument for their specific viscosity measurement needs, whether for routine quality checks or R&D testing. The inclusion of NIST-traceable certificates on select models provides traceability to national standards, which is important for regulated industries or internal quality audits. Overall, BYK Gardner instruments are a standard choice in many industrial laboratories for their reliability and adherence to established test methods.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
Worldwide
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Show
Page 1 of 1

About BYK GARDNER

BYK Gardner is a manufacturer of physical testing instruments for quality control in coatings, paints, inks, adhesives, and related liquid materials. The brand, part of the BYK-Chemie GmbH group, has a history dating back to the early 20th century and is recognized for its precision measurement tools used in laboratory and production environments. Primary product families include viscosity cups (such as Ford-style and flow cups), film applicators, gloss meters, color measurement devices, and other physical property testers. These instruments are designed to meet standardized test methods like ASTM D1200, ISO 2431, and others, ensuring repeatable and comparable results across different facilities. BYK Gardner viscosity cups, for example, are available in various orifice sizes to cover a range of viscosity from low to high (e.g., 25 cSt to 370 cSt), and many models come with NIST-traceable certificates for calibration assurance. The cups are typically made from corrosion-resistant materials such as anodized aluminum or stainless steel, with precision-machined orifices to maintain accuracy. Accessories like cup stands and flow cups complement the main product line, enabling consistent testing setups. 3G Electric supplies a selection of BYK Gardner viscosity cups and viscometer accessories, including Ford-style cups with different viscosity ranges and standard position stands. These items are available for global shipment, with logistics support to handle procurement for plant engineers, maintenance managers, and quality control specialists. The product range supports applications in paint manufacturing, ink production, adhesive formulation, and other industries where liquid viscosity is a critical parameter. By offering multiple SKUs with varying specifications, 3G Electric enables buyers to select the appropriate instrument for their specific viscosity measurement needs, whether for routine quality checks or R&D testing. The inclusion of NIST-traceable certificates on select models provides traceability to national standards, which is important for regulated industries or internal quality audits. Overall, BYK Gardner instruments are a standard choice in many industrial laboratories for their reliability and adherence to established test methods.

Common Applications

  • Paint manufacturing — BYK Gardner Ford-style viscosity cups for batch consistency checks in liquid paint production.
  • Ink formulation — BYK Gardner flow cups for viscosity control of printing inks during R&D and production.
  • Adhesive quality control — BYK Gardner viscosity cups for measuring adhesive viscosity to ensure proper application properties.
  • Laboratory testing — BYK Gardner viscosity cup stands for standardized setup in quality assurance labs.
  • Coating application — BYK Gardner Ford cups for verifying viscosity of industrial coatings before spray or dip application.
  • Research and development — BYK Gardner viscosity cups for evaluating new formulations in coatings and chemicals.

Frequently asked questions

Common questions about BYK GARDNER from 3G Electric.

What viscosity ranges do BYK Gardner Ford-style viscosity cups cover?

BYK Gardner Ford-style viscosity cups are available in multiple orifice sizes to cover a range of viscosity measurements. Based on the product listings, cups are offered with minimum viscosities as low as 25 cSt and maximum viscosities up to 370 cSt. For example, model SC-7201 covers 25 to 120 cSt, while SC-0174 covers 70 to 370 cSt. The specific range depends on the cup's orifice diameter and design, which conform to ASTM D1200 standards. Always verify the cup's specifications against your expected fluid viscosity to ensure accurate readings.

Do BYK Gardner viscosity cups come with NIST-traceable certificates?

Some BYK Gardner viscosity cups include a NIST-traceable certificate, but not all models. For instance, SKU 830GZ2 (MPN SC-0174) and SKU 830GY9 (MPN PV-0173) are listed with NIST-traceable certificates, while SKU 830GY7 (MPN PV-7201) and SKU 830GZ1 (MPN PV-0174) do not include one. The certificate provides traceability to the National Institute of Standards and Technology, which is useful for quality assurance and compliance with certain industry standards. Check the product specifications for each SKU to confirm if a certificate is included.

What accessories are available for BYK Gardner viscosity cups from 3G Electric?

3G Electric supplies viscometer accessories such as the BYK Gardner Standard Position Ford Viscosity Cup Stand (MPN PV-0430) and flow cups like the BYK Gardner Flow Cup (MPN PV-7208). The stand provides a stable platform for holding the cup during testing, ensuring consistent positioning and reducing operator error. Flow cups are alternative viscosity measurement devices that operate on similar principles but may have different orifice designs. These accessories complement the Ford-style cups and are available for separate purchase.

Are BYK Gardner viscosity cups suitable for use with paints and coatings?

Yes, BYK Gardner viscosity cups are commonly used in the paints and coatings industry for quality control of liquid products. The Ford-style cups are designed to measure the viscosity of paints, varnishes, and similar coatings according to ASTM D1200. The cups are made from materials resistant to solvents and chemicals typically found in coatings, such as anodized aluminum or stainless steel. For accurate results, ensure the cup is clean and the fluid is at the specified temperature, as viscosity is temperature-dependent.

How do I select the correct BYK Gardner viscosity cup for my application?

Selecting the correct BYK Gardner viscosity cup depends on the expected viscosity range of your fluid. The cups are labeled with minimum and maximum viscosity values, such as 25-120 cSt or 70-370 cSt. Choose a cup where your fluid's viscosity falls within that range for optimal accuracy. Also consider the cup's orifice size, which affects flow time. For example, a cup with a larger orifice (e.g., #4 Ford cup) is suitable for higher viscosity fluids. Refer to the product specifications and ASTM D1200 guidelines for detailed selection criteria.

Can BYK Gardner viscosity cups be used for non-Newtonian fluids?

BYK Gardner viscosity cups are primarily designed for Newtonian or near-Newtonian fluids, where viscosity is constant regardless of shear rate. For non-Newtonian fluids (e.g., those that are shear-thinning or thixotropic), the flow time through a cup may not provide a true viscosity value, as the shear rate varies during the test. However, they can still be used for comparative quality control if the fluid behavior is consistent. For accurate measurement of non-Newtonian fluids, rotational viscometers or rheometers are recommended.