ICM
Frequently asked questions
Common questions about ICM from 3G Electric.
What is the operating voltage range for ICM time-delay relays like the ICM102B?
The ICM ICM102B adjustable time-delay relay operates on 18 to 240V AC. It is configured for on-delay operation with a delay range of 1.5 to 600 seconds, adjustable via a knob. The relay has a 1.5 A rating and uses a surface-mount style with 2 pins.
Are ICM ignition transformers like the ICM1501 compatible with specific burner models?
Yes, the ICM1501 ignition transformer is compatible with Honeywell R8184G1161, R8184G1294, and R8184G4066 models. It is designed for oil-fired hot water and steam boiler burners, mounts via bracket, and has overall dimensions of 4-7/16 in x 4-1/16 in x 2-5/16 in.
What does the ICM492D line voltage monitor display and what parameters does it monitor?
The ICM492D line voltage monitor features an LCD display and monitors single-phase line voltage. It has an adjustable percentage voltage unbalance range of 5% to 25% and uses SPDT - NO/NC contacts. The operating voltage is 18V AC to 240V AC.
Can ICM furnace control boards like the ICM288 replace OEM boards from Rheem?
Yes, the ICM288 furnace control board is an OEM replacement compatible with Rheem equipment, specifically replacing part number 62-24084-82. It operates at 24V AC and controls inducers. The board is designed for integrated furnace control applications.
What temperature ranges are available for ICM temporary construction thermostats?
ICM temporary construction thermostats in the ACH series are available in heat-only or cool-only models. Setpoints include 45°F, 55°F, and 65°F, with a 9°F temperature differential. They operate on 18 to 30V AC and have a cylindrical shape with universal mounting direction.
Does 3G Electric supply ICM products?
Yes — 3G Electric (S) Pte. Ltd. supplies ICM products. We stock the ICM catalog and supply genuine factory-original products with full manufacturer warranty and technical support.