We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
Elster logo

Elster

GermanyAccessories & Installation

Elster, a brand with a long history in gas measurement and control, is a recognized name in the field of utility and industrial gas metering. Originally established through the merger of several European gas equipment manufacturers, Elster's product lines have become a common specification in gas distribution networks, large industrial facilities, and commercial metering installations. The brand's focus is on mechanical and electronic gas meters, pressure regulators, and associated control equipment, engineered for accurate measurement and reliable operation in demanding environments. For procurement specialists and plant engineers, Elster represents a dependable choice for custody transfer, process monitoring, and sub-metering applications where repeatable accuracy and robust construction are non-negotiable.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
Germany
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Show
Page 1 of 2
← Prev12Next →

About Elster

Elster, a brand with a long history in gas measurement and control, is a recognized name in the field of utility and industrial gas metering. Originally established through the merger of several European gas equipment manufacturers, Elster's product lines have become a common specification in gas distribution networks, large industrial facilities, and commercial metering installations. The brand's focus is on mechanical and electronic gas meters, pressure regulators, and associated control equipment, engineered for accurate measurement and reliable operation in demanding environments. For procurement specialists and plant engineers, Elster represents a dependable choice for custody transfer, process monitoring, and sub-metering applications where repeatable accuracy and robust construction are non-negotiable.

3G Electric supplies a comprehensive range of Elster gas meters, covering the QA series of turbine meters and the MQM series of diaphragm meters. The QA series, which includes models such as the QA16, QA25, QA40, QA100, QA160, QA250, and QA400, is designed for medium to high flow rate applications. These meters are available in nominal diameters from DN25 to DN150, with flow capacities ranging from 25 m³/h up to 650 m³/h. They are constructed with aluminum bodies, making them suitable for natural gas, air, methane, nitrogen, and other non-corrosive gases. The measuring range of 1:20 allows for accurate measurement across a wide turndown, which is critical for variable load conditions. Accuracy is rated at ±1.5% within the range of 0.2 Qmax to Qmax, meeting the requirements for many utility and industrial metering standards. Pressure ratings go up to 16 bar (PN 16), and the meters can be equipped with various output options, including Namur, optical interfaces, M-BUS, and L-BUS, facilitating integration into existing telemetry or building management systems.

The MQM series, represented by the MQM10, is a compact diaphragm gas meter with a 1-inch connection and a maximum flow rate of 16 m³/h. This type of meter is typically used for smaller commercial or light industrial loads where a positive displacement meter is preferred for its accuracy at low flow rates. The MQM series is known for its long-term stability and low pressure loss, making it a practical choice for sub-metering or as a check meter.

3G Electric maintains a substantial inventory of Elster gas meters, ensuring availability for both scheduled maintenance and emergency replacements. Each unit is supplied with full datasheets, and our logistics team coordinates global shipping to meet project timelines. For engineers and procurement managers, 3G Electric provides a single point of contact for sourcing Elster meters, with support for specification verification and order fulfillment. Whether the requirement is for a single meter or a batch for a distribution network, 3G Electric offers the technical documentation and supply chain reliability needed to keep gas systems operational.

Common Applications

  • Natural gas distribution networks — Elster QA40 turbine meters for medium-pressure metering stations
  • Industrial process gas measurement — Elster QA160 meters for monitoring methane flow in manufacturing
  • Commercial building sub-metering — Elster MQM10 diaphragm meters for tenant billing
  • Custody transfer applications — Elster QA100 meters with M-BUS output for utility billing
  • Compressed air monitoring — Elster QA25 meters for air flow measurement in plant utilities
  • Nitrogen supply systems — Elster QA250 meters for inert gas flow in chemical processing
Origin: Manufactured in Germany

Related brands we carry

Comparable manufacturers in the same product category.

Frequently asked questions

Common questions about Elster from 3G Electric.

What is the difference between the Elster QA series and the MQM series gas meters?

The Elster QA series consists of turbine flow meters, which are designed for higher flow rates, typically from 25 m³/h up to 650 m³/h, with nominal diameters ranging from DN25 to DN150. These meters are suitable for industrial and utility applications where large volumes of gas are measured. The MQM series, on the other hand, is a diaphragm meter, which is a positive displacement meter. The MQM10, for example, has a maximum flow rate of 16 m³/h and a 1-inch connection. Diaphragm meters are preferred for smaller loads, such as commercial buildings or light industrial processes, because they maintain accuracy at low flow rates. The choice between the two depends on the expected flow range and the required turndown ratio.

What are the typical accuracy specifications for Elster QA series gas meters?

Elster QA series gas meters are rated with an accuracy of ±1.5% within the flow range of 0.2 Qmax to Qmax. This accuracy is maintained across the meter's measuring range of 1:20, which means the meter can accurately measure flow rates from 5% to 100% of its maximum capacity. For example, a QA40 with a maximum flow of 65 m³/h will maintain ±1.5% accuracy from approximately 13 m³/h up to 65 m³/h. This level of accuracy makes these meters suitable for custody transfer and process monitoring applications where precise measurement is required for billing or regulatory compliance.

Can Elster QA series meters be used for gases other than natural gas?

Yes, Elster QA series meters are designed to measure a variety of non-corrosive gases. According to the product specifications, they are suitable for natural gas, air, methane, nitrogen, and other inert gases. The aluminum body construction is compatible with these media, and the meters are calibrated for the specific gas density and viscosity. However, it is important to verify that the meter's calibration and any associated electronic components are configured for the specific gas being measured. For gases with different properties, such as higher density or corrosiveness, a different meter type may be required. Always consult the datasheet or contact 3G Electric for guidance on gas compatibility.

What output options are available on Elster QA series gas meters?

Elster QA series gas meters can be equipped with several output options to facilitate remote reading and integration into control systems. Common options include a Namur inductive sensor (E200), an optical interface, M-BUS, and L-BUS. The Namur sensor is a standard for industrial environments, providing a pulse output that can be connected to a counter or PLC. The optical interface allows for local reading with a handheld device. M-BUS and L-BUS are communication protocols used for remote data collection in utility networks. These outputs enable the meters to be used in automated metering infrastructure (AMI) or building management systems, allowing for real-time monitoring and data logging.

What is the maximum pressure rating for Elster QA series gas meters?

Elster QA series gas meters are pressure-rated to 16 bar, which corresponds to PN 16. This rating is consistent across the series, including models like the QA100 and QA160. The meters are designed to withstand this pressure safely, and the aluminum body is tested to meet the required safety standards. For applications with higher pressure requirements, additional pressure reduction or regulation equipment would be needed upstream of the meter. It is essential to ensure that the meter's pressure rating matches the operating conditions of the gas system to avoid damage or safety hazards. Always verify the pressure rating on the datasheet before installation.

How do I select the correct Elster gas meter size for my application?

Selecting the correct Elster gas meter size involves determining the expected flow rate range and the available pressure. The QA series offers a range of models with different maximum flow capacities, from 25 m³/h (QA16) to 650 m³/h (QA400). The meter should be sized so that the expected minimum and maximum flow rates fall within the meter's measuring range, which is typically 1:20. For example, if your application has a minimum flow of 10 m³/h and a maximum of 200 m³/h, a QA160 with a capacity of 250 m³/h would be appropriate, as its range would be from 12.5 m³/h to 250 m³/h. It is also important to consider the pipe size and connection type. 3G Electric can assist with sizing calculations based on your specific flow data and site conditions.