We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S - Programmer & Amplifier Modules
FireyeProgrammer & Amplifier Modules

Fireye Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S

The Fireye Flame-Monitor EP Programmer Modules are programmer and amplifier modules offered in models EP100S, EP200S, EP300S, EP160, EP161, EP163, EP170, EP174, EP165, EP166, EP177, EP260, EP265, EP270, EP380, EP381…

SKU 3G-OTH-02816

Also listed as: MONITOREPPROGRAMMER · MONITOR EP PROGRAMMER

Brand
Fireye
Item
Flame-Monitor EP Programmer Modules. The Fireye programmer modules
Category
Programmer & Amplifier Modules
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
EP100S, EP200S, EP300S, EP160, EP161, EP163, EP170, EP174, EP165, EP166, EP177, EP260, EP265, EP270, EP380, EP381, EP382, EP383
Category
Programmer & Amplifier Modules
Approvals
cULus, FM Approved
EP163, EP177
Programmable via the ED510 Display Module, offering advanced configuration options.
Safety Checks
Includes open damper (high purge) prepurge, proof of low fire position, and fuel valve end switch safety checks.
Dipswitch Settings
Most modules feature six dipswitches for configuring operational characteristics: Forced Blower Motor Start Delay (Dipswitch 1, inactive for some models) Extended Purge Timing (Dipswitches 3, 4, 5) 3-P Running Interlock Circuit Requirement (Dipswitch 6) For models EP163, EP177, and EP383, settings are managed via the ED510 Display Module instead of dipswitches.
EP260, EP265, EP270
Include essential start-up and safety checks with configurable dipswitch settings.
EP100S, EP200S, EP300S
Configurable via dipswitch settings.
Running Interlock Circuit
Continuously monitors limit switches, airflow switches, and fuel pressure switches. If any circuit opens at an inappropriate point, the control initiates a safety lockout or recycling process (depending on model settings).
EP160, EP161, EP170, EP174
Provide robust safety and control features with configurable dipswitch settings.
Flame Monitoring Supervision
Monitors flame presence for safe operation.
EP380, EP381, EP382, EP383, EP390
Feature extended purge timing and configurable operational modes, with the EP383 programmable via the ED510 Display Module.
Start-Up Programming and Safe-Start Check
Ensures proper ignition sequence and system readiness.

Datasheet Content

[{"filename":"EP380-SPEC-Flame_Monitor_Programmer_Modules_EP380_English_2013-06-01.pdf","text":"SPECIFICATION DATA\n EP380 PROGRAMMER MODULE\n\n\nFeatures\n\n• Selectable Operation. The dipswitches allow\n easy replacement of the EP260, EP261 (Extended\n MTFI), EP270 (Early Spark Termination), and\n EP265 (Pilot Stabilization) programmers.\n\n• Selectable Purge Timings. Purge Timings easily\n selectable from 30 seconds to 30 minutes using\n dipswitches.\n\n• Air Flow Proven Open To Start. This feature\n can be enabled or disabled using the dipswitches.\n\n• Compatible with ED510. Use with the display\n module ED510. (See Bulletin ED-510-SPEC for\n more information.)\n\n• Backward compatible. Easy to upgrade with all\n existing FLAME-MONITOR controls.\n\n• Continuous Status Indication. as well as diag-\n nostic information.\n FLAME-MONITOR System and incorporates a plug-\nApplication in design for ease of installation. It is micro-processor\n based that provides a continuous readout of the oper-\n The Fireye EP380 Programmer Module is used ating status of the FLAME-MONITOR control. It\nwith the FLAME-MONITOR™ Burner Management also stores the burner cycle and on-time history, lock-\nControl System (P/N's E100 and E110). The EP380 out history (with burner cycle and burner hour time\nprovides start-up programming, safe start check, and stamp) that is accessible with the ED510 alpha-\nflame monitoring supervision. It insures proof of low numeric display or E500 Communication Interface. If\nfire position, and fuel valve end switch safety checks. replaced, the new programmer card will begin accu-\nThe control is designed to initiate a safety lockout if mulating a new history.\nany of these circuits open at the improper point in the\ncontrol cycle. A running interlock circuit on the\nFLAME-MONITOR system constantly monitors the Ordering Information\nlimit switches, air flow switches, and fuel pressure\nswitches through the programmer. A modulator (fir- The EP380 Programmer module with selectable\ning rate motor) circuit is not provided on the EP380 operation is used to replace EP380, EP381 (15 sec-\nProgramer Module. ond purge), EP382 (1 second purge), and EP390 (90\n The programmer module will de-energize all fuel second purge) programmer modules.\nvalve circuits within four (4) seconds (max.) follow-\ning a flame failure or at the end of the pilot trial for\nignition period if no flame is detected. An alarm cir-\ncuit will be energized following a safety lockout.\n The EP380 programmer is the heart of the\n\n EP-380-SPEC\n\fDescription of Dipswitch Functions\n\n DIPSWITCH POSITION\n U = UP DN = DOWN\n FUNCTION\n 1 2 3 4 5 6\n Dn Recycle on 3-P Open\n Up Non Recycle on 3-P Open\n\n Dn 15 Sec Post\n Up 10 Sec Purge\n\n Dn Dn Dn 30 sec.— EP380\n Dn Dn Up 1 sec.— EP382\n Dn Up Dn 5 sec. Selectable High Fire\n Purge Timing\n Dn Up Up 15 min. — EP381\n Up Dn Dn 90 min.— EP390\n Low Fire Purge Timing\n Up Dn Up 2 min. 30 sec. (min.)\n Up Up Dn 5 min.\n Up Up Up 10 min.\n Dn Prove 3-P Open DISABLED\n Up Prove 3-P Open ENABLED\n\n\n\n\nTiming Chart for EP380\n Refer to Bulletin EP-3801 for dipswitch settings and timing charts of EP380 configured as\n EP381 (15 second purge), EP382 (1 second purge), and EP390 (90 second purge).\n\n\n\n\n Type EP380\n SELECTABLE OPERATION (RECYCLE OR NON-RECYCLE) RUNNING INTERLOCKS (3/P)\n PURGE TIME - 30 SEC.1 FLAME FAILURE RESPONSE TIME 4 SEC.\n PROGRAMMING SEQUENCE\n LFS FIRING\n L1/13\n CLOSED L1/13\n ON\n T M\n E PURGE 1 SEC1 POST PURGE2\n R MINIMUM 15 SEC\n M X* PTFI\n I\n N 5\n A PTFI MTFI\n L\n 6\n 7\n * TERMINAL “X” USAGE REQUIRES JUMPERING “5” & “10” ON THE WIRING BASE\n\n\n\n\n FIREYE EP-380-SPEC\n 3 Manchester Road JUNE 2013\n Derry, New Hampshire 03038 supersedes February 1994"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye Flame-Monitor EP Programmer Modules are programmer and amplifier modules offered in models EP100S, EP200S, EP300S, EP160, EP161, EP163, EP170, EP174, EP165, EP166, EP177, EP260, EP265, EP270, EP380, EP381, EP382, and EP383. These modules carry cULus and FM Approvals. Most modules feature six dipswitches for configuring operational characteristics such as Forced Blower Motor Start Delay, Extended Purge Timing, and 3-P Running Interlock Circuit Requirement; models EP163, EP177, and EP383 are programmable via the ED510 Display Module. Safety checks include open damper (high purge) prepurge, proof of low fire position, and fuel valve end switch checks, and the Running Interlock Circuit continuously monitors limit switches, airflow switches, and fuel pressure switches.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye Flame-Monitor EP Programmer Module used for?

The Fireye EP Programmer Module is used with the Flame-Monitor Burner Management Control System to provide start-up programming, safe start checks, and flame monitoring supervision. It ensures proof of low fire position and fuel valve end switch safety checks, initiating a safety lockout if circuits open improperly.

What are the specifications of the Fireye EP380 programmer module?

The Fireye EP380 programmer module features selectable purge timings from 30 seconds to 30 minutes via dipswitches, and is compatible with the ED510 display module. It replaces EP260, EP261, EP270, and EP265 programmers. Approvals include cULus and FM. It does not include a modulator circuit.

Where to buy Fireye Flame-Monitor EP programmer modules in Singapore?

You can source Fireye Flame-Monitor EP programmer modules through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on these Fireye modules.

How to select the right Fireye EP programmer module for my burner control system?

Select the Fireye EP module based on your system's purge timing and operational needs. For example, the EP380 offers selectable purge from 30 seconds to 30 minutes and can replace EP260, EP261, EP270, and EP265. The EP163 and EP177 are programmable via the ED510 display module. Consult your system manual for compatibility.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye programmer & amplifier modules. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Flame-Monitor E300 Expansion Module. The E300 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Fireye
Flame-Monitor E300 Expansion Module. The E300 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Flame-Monitor E320 Expansion Module. The E320 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Fireye
Flame-Monitor E320 Expansion Module. The E320 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
ED510 Display Module. The ED510 Display Module is engineered to integrate seamlessly with the Flame-Monitor Burner Management Control System. It is compatible with EP and EPD style (remote mount only for EPD style) programmer modules, as well as the MicroM series of controls
Fireye
ED510 Display Module. The ED510 Display Module is engineered to integrate seamlessly with the Flame-Monitor Burner Management Control System. It is compatible with EP and EPD style (remote mount only for EPD style) programmer modules, as well as the MicroM series of controls
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
Fireye
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
Controller module for burner management systems. Provides sequencing and supervision of burner operations in commercial and industrial heating applications
Fireye
Controller module for burner management systems. Provides sequencing and supervision of burner operations in commercial and industrial heating applications

More from Fireye

View all Fireye parts
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Fireye
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
Fireye
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
Fireye
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods
Fireye
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods