We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Supco Vacuum fittings - HVAC Equipment
SupcoHVAC Equipment

Supco Vacuum fittings

Supco vacuum fittings for HVAC systems feature 1 Micron resolution and 0.5 second response time, with 1/4" female flare swivel connectors. Auto-shutoff engages after 10 minutes above 12,000 Microns, providing…

SKU 3G-CBM-01301

Also listed as: COP 18006 · COP-18006

Brand
Supco
Item
Vacuum fittings
Category
HVAC Equipment
UNSPSC
40101709 — Air handling unit
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Supco
resolution
1 Micron
sensor type
Thermistor
auto shutoff
After 10 minutes above 12,000 Microns
response time
0.5 seconds
connector type
1/4" female flare swivel

Datasheet Content

VG64S DIGITAL VACUUM GAUGE FEATURES • Ultra fine resolution (as low as 1 Micron) • ½ second response time • Auto shut off • Convenient built in hanger • Easy access cleaning port SPECIFICATIONS Sensor Type Thermistor Connector Type Standard 1/4” female flare swivel. Also Included: 1/4” x 1/4” male flare union Vacuum Range 0 – 12,000 Microns (0 – 1,600 Pascals) with vacuum increasing/ decreasing indicator when above 12,000 Microns Scale Microns, PSI, InHg, milliBars, Pascals, Torr, milliTorr Resolution 0-200: 1 Micron 201-500: 5 Microns 501-1,000: 10 Microns 1,001-2,000: 50 Microns 2,001-5,000: 250 Microns 5,001-8,000: 500 Microns 8,001-12,000: 1,000 Microns Operating 35°F to 125°F ( 2°C to 52°C) Temp.Range Overpressure 500 PSI maximum Accuracy +/-10% or +/-10 Microns, whichever is larger (0 to 1000 microns) Power Source 9 Volt Alkaline Battery (not included) Battery Life Over 35 Hours Auto Shutoff After 10 minutes when vacuum reading is above 12,000 Microns (12 Torr) Weight 6.7 ounces Dimensions 6½²H X 3²W X 1¼²D OPTIONAL ACCESSORIES 9 Volt AC Adapter Part number 10475 Vinyl Case Part number 10740 OPERATING CONTROLS CONNECTING THE VG64S Vacuum Gauge Service Hose VG64S TO THE • Turning the vacuum gauge ON: Press and hold the ON VACUUM SYSTEM button for approximately 3 seconds, until the display The VG64S should be Main Shut Off Valve Gauge Valve appears. connected to the To System vacuum system at Vacuum Pump Valve • Turning the vacuum gauge OFF: Press the OFF button. To the vacuum port. Valve For prolong battery life, when vacuum reading is above Pressurizing System or 12,000 Microns for approximately 10 minutes, the Breaking Vacuum Vacuum Pump To Atmosphere VG64S will automatically turn OFF. • Changing the scale: Press the Scale button to change CLEANING THE VG64S VACUUM SENSOR the display to the next scale. The scale order is: It is recommended that the VG64S sensor be cleaned periodically Microns, PSI, Inches of mercury (InHg), milliBars, to maintain unit accuracy. Oil and other contaminants reduce the Pascals, Torr and milliTorr. The VG64S will keep the accuracy of the VG64S unit. Follow the instructions below for cleaning. scale settings even if the power is turned OFF. • Use an eyedropper to pour approximately 1 teaspoons of ordinary rubbing alcohol into the vacuum port. • Shake the VG64S unit for approximately 10 seconds. A slight UNDERSTANDING THE DISPLAY movement of the vacuum sensor in the case is normal and does not affect the internal connection in any way. • When the vacuum reading is above 12,000 Microns • Empty the alcohol and air dry the sensor. (1,600 Pascals), the first line of the display shows "Atm." The second line displays a bar graph to indicate the direction in which the vacuum is moving. When the bar CHECKING HVAC SYSTEMS FOR LEAKS graph is moving from left to right, the pressure is When checking a system for leaks use only copper tubing and a increasing. When the bar graph is moving from right to vacuum proof valve. Generally standard hoses will not hold a left, the pressure is decreasing. The speed of the bar vacuum. If using the blank-off valve on the vacuum pump check it graph indicates how fast the pressure is increasing or for leaks periodically. At the beginning of the test the VG64S reading decreasing. The bar graph indicator may be inaccurate may increase due to a system equalization. The vacuum reading for a few seconds after the evacuation of the system has should hold after a minimum of 5 minutes. If the reading continues begun. to increase it may indicate a leak in the system. • The bar graph disappears if the vacuum does not change for approximately 10 seconds. • When the vacuum reading is below 12,000 Microns (1,600 Pascals), the vacuum in the selected units is displayed.

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Supco Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Supco vacuum fittings for HVAC systems feature 1 Micron resolution and 0.5 second response time, with 1/4" female flare swivel connectors. Auto-shutoff engages after 10 minutes above 12,000 Microns, providing reliable evacuation control for refrigeration and air conditioning applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy Supco COP18006 vacuum fittings in the Philippines?

3G Electric Philippines supplies Supco COP18006 vacuum fittings with delivery to Manila and Quezon City. We handle all logistics and Bureau of Customs documentation. Lead time on request — contact us for current availability and PHP invoicing.

What is the lead time for Supco COP18006 vacuum fittings?

Lead time varies based on current availability. 3G Electric sources Supco products for delivery to the Philippines, handling all documentation and customs clearance. Request a quote for specific delivery dates and PHP pricing.

What applications are Supco COP18006 vacuum fittings suitable for?

Supco COP18006 fittings are designed for HVAC refrigeration and air conditioning evacuation systems. The 1 Micron resolution, 0.5 second response time, and auto-shutoff (after 10 minutes above 12,000 Microns) provide reliable control for precision evacuation procedures.

Used in

Common applications for Supco
Commercial refrigeration display cases — Supco RO82 relay and CSS-25U starter for compressor motor control without run capacitors
Medium-load HVAC systems — Supco SPP 6/SPP 8 hard-start devices to reduce compressor inrush current and extend motor lifespan
Cold-chain pharmaceutical and food storage — SL300TH temperature–humidity data logger for continuous monitoring and regulatory documentation
Refrigerant service operations — Piercing valves and perforator cocks in 1/2" and 5/8" sizes for fast, non-invasive line access
Compressor thermal management — Universal Compressor Door for reducing shell temperature and improving efficiency in hot ambient conditions
Retrofit and field repairs — Supco controls with Quick Connect terminals for rapid installation in legacy refrigeration circuits

Supco Products

3G Electric supplies Supco hvac equipment. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Vacuum gauge VG 640
Supco
Vacuum gauge VG 640
Supco
Supco
Vacuum gauge + alarm VG64OT
Supco
Supco
Universal nitrogen purge connector
Digital vacuum gauge VG64
Supco
Digital vacuum gauge VG64
Piercing valve outlet 1/2" and 5/8"
Supco
Piercing valve outlet 1/2" and 5/8"
Supco
Supco
Universal level for copper 3/8" to 2"

More from Supco

View all Supco parts
Supco
Supco
Axial fan motor D.350 380V THREE-PHASE
CSS-32U 32A starting module
Supco
CSS-32U 32A starting module
Supco
Supco
Axial fan motor D.350 230V single phase with square plate
Supco
Supco
Axial fan motor D.500 380V three-phase with square plate
Supco
Supco
Axial fan motor D.630 230V single-phase with square plate
Supco
Supco
Axial fan motor D.300 380V 3-PHASE
Supco
Supco
Telescopic thermometer -50..+300°C L.max:914mm
Supco
Supco
Axial fan motor D.400 230V single-phase with square plate