We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR X G X5S TC S - Burners & Combustion
FBRBurners & Combustion

FBR X G X5S TC S

FBR X G X5S TC S is a single-stage light-oil diesel burner designed for industrial heating applications. It delivers 142–356 kW thermal power with a fuel flow rate of 12–30 kg/h, featuring a 450 W fan motor and IP 40…

SKU 3G-FBR-00042

Brand
FBR
Item
X G X5S TC S
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
25 kg
stage
Single stage
fuel type
Light oil
nozzle mm
215
fan motor w
450
preheater w
30-110
power kw max
356
power kw min
142
flow kg h max
30
flow kg h min
12
ip protection
IP 40
noisiness dba
71-72
electrical supply
1
power supply info
1N~230V
current absorption a
2.7
thermal power mcal h
122-306
nominal electric power w
600
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS ONE STAGE SK070044_A_en LIGHT-OIL BURNERS ONE STAGE G X3H - G X3S - G X4H - G X4S - G X5H - G X5S Light-oil burners single stage. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micro adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions H hydraulic device of closing air shutter. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G X3H - G X3S Fig. 2 G X4H - G X4S G X3H - G X3S - G X4H - G X4S - G X5H - G X5S LIGHT-OIL BURNERS ONE STAGE SK070044_A_en TECHNICAL DATA G X3H - G X3S - G X4H - G X4S - G X5H - G X5S MODEL G X3H G X4H G X5H G X3S G X4S G X5S Flow min. - max. * [kg/h] 7-15 10-20 12-30 Thermal power min. - max. * [Mcal/h] 71-153 102-204 122-306 Thermal power min. - max. * [kW] 83-178 118-236 142-355 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 220 250 600 Fan motor [W] 150 200 450 Nominal current absorption [A] 1 1.1 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [db(A)] 66-66 67-68 71-72 Burner weight *** [kg] 14 14 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with cover in steel (F) please add 5 kg to the weight. OPERATING RANGE DIAGRAM G X3H - G X3S - G X4H - G X4S - G X5H - G X5S Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X3H - G X3S - G X4H - G X4S - G X5H - G X5S LIGHT-OIL BURNERS ONE STAGE SK070044_A_en DIMENSIONS [MM] Fig. 4 Dimensions G X3H - G X3S - G X4H - G X4S - G X5H - G X5S MODEL A B C D E F G H I G X3H 182 192 318 110 306 248 17 200 200 G X3S G X4H 182 192 318 124 306 248 17 200 200 G X4S G X5H 210 218 400 130 461 310 18 200 200 G X5S * See "flame tube length" G X3H - G X3S - G X4H - G X4S - G X5H - G X5S LIGHT-OIL BURNERS ONE STAGE SK070044_A_en BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L max M N min N* N max G X3H mm 160 226 M10 120 130 140 G X3S G X4H mm 170 226 M10 130 140 160 G X4S G X5H mm 205 226 M10 140 150 180 G X5S FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G X3H mm 130 250 G X3S G X4H mm 130 250 G X4S G X5H mm 215 335 G X5S ** For different flame lengths, please contact our Technical-Sales Department. G X3H - G X3S - G X4H - G X4S - G X5H - G X5S LIGHT-OIL BURNERS ONE STAGE SK070044_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners one stage. DETAILED SPECIFICATION Light-oil burner one stage composed by: • Aluminium frame; • Combustion head with micro adjustment at high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X3H - G X3S - G X4H - G X4S - G X5H - G X5S
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G X5S TC S is a single-stage light-oil diesel burner designed for industrial heating applications. It delivers 142–356 kW thermal power with a fuel flow rate of 12–30 kg/h, featuring a 450 W fan motor and IP 40 protection for reliable operation in demanding environments.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy an FBR X G X5S TC S diesel burner in the Philippines?

Order the FBR X G X5S TC S from 3G Electric Philippines. We deliver to Manila, Quezon City, and CALABARZON regions. 3G Electric handles all Bureau of Customs documentation, PHP invoicing, and logistics to your site. Lead time on request.

What is the lead time and shipping cost to the Philippines?

Lead time and shipping cost depend on current availability and your location within the Philippines. Contact 3G Electric Philippines with your delivery address for a firm quote. We handle all customs clearance and documentation.

What is the thermal power output and fuel consumption of the FBR X G X5S TC S?

The FBR X G X5S TC S delivers 142–356 kW thermal power with a fuel flow rate of 12–30 kg/h. It features a single-stage design, 450 W fan motor, IP 40 protection, and operates on 1N~230V electrical supply. Ideal for industrial heating in food processing and packaging applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G X5 TC S
FBR
X G X5 TC S
X G X5H TC c
FBR
X G X5H TC c
X G X5S TL S
FBR
X G X5S TL S
X G X5.22 TC SI
FBR
X G X5.22 TC SI
X G X 5.22 LX TC S
FBR
X G X 5.22 LX TC S
X G X3 TC S
FBR
X G X3 TC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL