We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR X G X5.22 TC SI - Burners & Combustion
FBRBurners & Combustion

FBR X G X5.22 TC SI

FBR X G X5.22 TC SI is a two-stage light-oil diesel burner engineered for low-NOx combustion, delivering thermal power of 147–450 mcal/h with NOx emissions below 120 mg/m³. Rated at 391.4 kW maximum output, it suits…

SKU 3G-FBR-00044

Brand
FBR
Item
X G X5.22 TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
215
fan motor w
0.74
power kw max
391.4
power kw min
166
flow kg h max
33
flow kg h min
14
ip protection
IP 40
noisiness dba
77
electrical supply
1
power supply info
3~400V, 1N~230V 50Hz
current absorption a
2
thermal power mcal h
147/204-450
nominal electric power w
1.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en LIGHT-OIL BURNERS AT TWO STEPS PRESSURE G X3.22 - G X4.22 - G X5.22 Light-oil burners at two steps pressure. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micrometric adjustment, high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G X3.22 Fig. 2 G X4.22 G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en TECHNICAL DATA G X3.22 - G X4.22 - G X5.22 MODEL G X3.22 G X4.22 G X5.22 Flow min. 1st st. / min. 2nd st. - max. 2nd st. * [kg/h] 4.8/7-15 6.8/10-20 9/12-30 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [Mcal/h] 49/71-153 69/102-204 92/122-306 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [kW] 57/83-178 80/118-236 107/142-355 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 220 250 600 Fan motor [W] 150 200 450 Nominal current absorption [A] 1 1.1 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 66-66 67-68 71-72 Burner weight *** [kg] 14 14 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with iron cover (F) add 3 kg to the weight. OPERATING RANGE DIAGRAM G X3.22 - G X4.22 - G X5.22 Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en DIMENSIONS [MM] Fig. 4 Dimensions G X3.22 - G X4.22 - G X5.22 MODEL A B C D E F G H I G X3.22 182 192 318 110 306 248 17 200 200 G X4.22 182 192 318 124 306 248 17 200 200 G X5.22 210 218 400 130 461 310 18 200 200 * See "flame tube length" BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L ** L max M N min N ** N max G X3.22 mm 160 170 226 M10 120 130 140 G X4.22 mm 170 205 226 M10 130 140 160 G X5.22 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** G X3.22 mm 130 250 G X4.22 mm 130 250 G X5.22 mm 215 335 *** For different flame lengths, please contact our Technical-Sales Department. G X3.22 - G X4.22 - G X5.22 LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners at two steps pressure. DETAILED SPECIFICATION Light-oil burners at two steps pressure, composed by: • Aluminium frame; • Combustion head with micrometric adjustment, high flame stability and low emissions; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • 7-poles plug for the electrical connections; • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X3.22 - G X4.22 - G X5.22
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G X5.22 TC SI is a two-stage light-oil diesel burner engineered for low-NOx combustion, delivering thermal power of 147–450 mcal/h with NOx emissions below 120 mg/m³. Rated at 391.4 kW maximum output, it suits industrial heating and process applications requiring clean, efficient fuel burning.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR X G X5.22 TC SI diesel burner in the Philippines?

Order from 3G Electric Philippines. We deliver to Manila, Quezon City, and CALABARZON industrial zones. 3G Electric handles all customs documentation and logistics to your site.

What is the lead time for the FBR X G X5.22 TC SI burner?

Lead time varies by stock status. Contact 3G Electric Philippines for availability and delivery schedule. We source from Italy and manage all Bureau of Customs clearance for PHP invoicing.

What thermal output and NOx emissions does the FBR X G X5.22 TC SI deliver?

Maximum output: 391.4 kW (147–450 mcal/h range). NOx emissions below 120 mg/m³ meet low-emission requirements for food processing and packaging plants. Two-stage modulating combustion ensures efficiency.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G X5.22 TL SI
FBR
X G X5.22 TL SI
G X5/2 TC SI
FBR
G X5/2 TC SI
X G X5 TC S
FBR
X G X5 TC S
X G X3.22 TC SI
FBR
X G X3.22 TC SI
G X5/2 TL SI
FBR
G X5/2 TL SI
X G X 5.22 LX TC S
FBR
X G X 5.22 LX TC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL