We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

The FBR K X5/2 LX4 TL is an industrial burner designed for high-capacity heating applications, delivering 154–850 kW with a 250 mm nozzle and 3-phase electrical supply, suitable for process heating and combustion…

SKU 3G-FBR-00255

Also listed as: 00430041 · 004300 41 · 004300-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
nozzle mm
250
power kw max
850
power kw min
154
electrical supply
3

Datasheet Content

BRUCIATORI MISTI DI GAS/GASOLIO BISTADIO DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] K X5/2 Dual fuel gas/light-oil burners at two stages. Composed by: aluminium frame, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: one-block valve class A (1st stage + 2nd stage slow opening + safety), minimum gas pressure switch and filter-stabilizer. Complete of: flange and gasket for installation on generator, nozzles, flexible pipes and line filter. Fig. 1 K X5/2 K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] TECHNICAL DATA AND OPERATING RANGE DIAGRAM K X5/2 MODEL K X5/2 Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 120.4/352.6-731 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 140/410-850 Gas flow G20 (NATURAL GAS) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14/41.1-85.2 Gas flow G31 (L.P.G.) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 5.4/15.9-33 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D1" - S NATURAL GAS/LPG ** [mbar] 72/53 Minimum pressure gas train D1"1/4 - S NATURAL GAS/LPG ** [mbar] 45/34 Minimum pressure gas train D1"1/2 - S NATURAL GAS/LPG ** [mbar] 28/23 Minimum pressure gas train D2" - S NATURAL GAS/LPG ** [mbar] 33/60 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 LIGHT-OIL flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 11.8/34.6-71.6 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 2.0 Fan motor [kW] 1.5 Nominal absorption fan motor [A] 3.2 Pump motor [kW] 0.37 Nominal absorption pump motor [A] 1.2 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 Burner weight [kg] 62 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). [mbar] [kW] Fig. 2 X = Thermal power Y = Pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] DIMENSIONS [MM] H D R1 G S RD B C TC-TL** E R2 R4 R3 F1 - F2* Fig. 3 Dimensions: K X5/2 MODEL A B C D E F1 F2* G H I L S R1 R2 R3 R4 RD Gas train weight K X5/2 - D1"-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 438 504 Rp1 23 kg K X5/2 - D1"1/4-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 438 504 Rp 1 1/4 23 kg K X5/2 - D1"1/2-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 430 520 Rp 1 1/2 25 kg K X5/2 - D2"-S 300 245 388 175 122 794 1234 416 171 144 10 18 250 380 430 520 Rp 2 25 kg F2*: Encumbrance with burner move back. TC-TL**: see chapter "FLAME TUBE LENGTH" BOILER PLATE *** Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L max M N min N * * * N max K X5/2 mm 310 368 M12 185 185 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL **** K X5/2 mm 250 315 **** For different flame lengths, please contact our Technical-Sales Department. K X5/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073516_A_gb [K X5/2] PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at two stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at two stages, composed by: • Aluminium frame; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with blast tube and flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Equipped with gas train with one-block valve class A (1st stage + 2nd stage slow opening + safety); gas pressure switch and stabilizer filter; • Gas valve proving system VPS as฀optional; • Motor dedicated for the light-oil pump; it turns on simultaneously to the ignition transformer activation; • Maximum gas pressure switch as฀optional; • UV probe for flame detection; • Supports and tierods for burner extraction; • Servomotor for air shutter and for the consent of the 2nd stage operation; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive LVD; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MD; • Directive PED (art.4, par.3) 2014/68/EU; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. K X5/2

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR K X5/2 LX4 TL is an industrial burner designed for high-capacity heating applications, delivering 154–850 kW with a 250 mm nozzle and 3-phase electrical supply, suitable for process heating and combustion systems requiring modulating power control.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR K X5/2 LX4 TL burner in the Philippines?

Source the FBR K X5/2 LX4 TL from 3G Electric Philippines. We deliver to Manila, Quezon City, and throughout CALABARZON industrial zones. 3G Electric handles Bureau of Customs documentation, logistics, and PHP invoicing for all orders.

What is the lead time for the FBR K X5/2 LX4 TL burner?

Lead time on request. The FBR K X5/2 LX4 TL is available to order through 3G Electric Philippines. Contact us for a quote and delivery schedule to your facility. We coordinate all import and local logistics.

What power range and nozzle size does the FBR K X5/2 LX4 TL deliver?

The FBR K X5/2 LX4 TL provides 154–850 kW modulating output with a 250 mm nozzle and 3-phase electrical supply. It is suited for high-capacity process heating and combustion systems requiring variable power control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X5/2 LX4 TC | Variant: variant_2
FBR
K X5/2 LX4 TC | Variant: variant_2
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K X5/2 TC | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TC | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL