We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

The FBR K X6/2 EVO TL is a dual-fuel gas and light-oil burner designed for industrial heating applications. Operating at 2 stages with a maximum thermal power of 1118 mcal/h and noise level of 82-83 dBA, it delivers…

SKU 3G-FBR-00177

Also listed as: 00431831 · 004318 31 · 004318-31

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
stage
2 stages
fuel type
Dual fuel gas/light oil
nozzle mm
400
fan motor w
2.2
power kw max
1300
power kw min
217
ip protection
IP 40
noisiness dba
82-83
pump motor kw
0.37
gas consumption
21.9/65.6-130.8
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
1.2
thermal power mcal h
187/561-1118
nominal electric power w
3
max combustion air temp c
60

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en BRUCIATORI MISTI DI GAS/GASOLIO BISTADIO K X6/2 EVO - K X7/2 Dual fuel gas/light-oil burners at two stages. Composed by die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train with multiblock valve class A (1st stage + 2nd stage slow opening + safety),valve proving system, gas pressure switch and filter-stabilizer. Complete of: flange and gasket for installation on generator, nozzles, flexible pipes and line filter. Fig. K X6/2 EVO - K X7/2 K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM K X6/2 EVO - K X7/2 MODEL K X6/2 EVO K X7/2� Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 187/561-1118 254/765-1548 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 217/652-1300 295/890-1800 Gas flow G20 (NATURAL GAS) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 21.9/65.6-130.8 29.7/89.5-181 Gas flow G31 (L.P.G.) 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 8.4/25.2-50.3 11.5/34.5-69.7 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)/I3B/P,I3+,I3P,I3B,I3R Minimum pressure gas train D2" - S NATURAL GAS/LPG ** [mbar] 39.8/19 39.8/19 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360 LIGHT-OIL flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 18.5/55-110 25/75-152 Fuel: LIGHT-OIL 1,5°E at 20°C= 6,2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 3 4.5 Fan motor [kW] 2.2 4 Nominal absorption fan motor [A] 4.35 7.45 Pump motor [kW] 0.37 0.37 Nominal absorption pump motor [A] 1.2 1.2 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en 16 K X6/2 EVO 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. 16 14 K X7/2 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en DIMENSIONS [MM] L I H A D A R1 S G TC-TL* E RD B C R4 R2 F1-F2 R3 Fig. Dimensions: K X6/2 EVO - K X7/2 MODEL A B C D E F1 F2** G H I L S R1 R2 R3 R4 RD Gas train weight K X6/2 EVO 320 240 402 209 148 963 1548 510 210 183 40 20 284 380 555 545 Rp2 25 kg K X7/2 320 240 398 209 148 963 1548 510 210 183 40 20 284 380 555 545 Rp2 25 kg F2*: Encumbrance with burner move back. TC-TL**: see chapter "FLAME TUBE LENGTH" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max K X6/2 EVO mm 340 368 M14 220 220 250 K X7/2 mm 340 368 M14 220 220 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL * K X6/2 EVO mm 280 ** 400 **฀With spacer. K X7/2 mm 280฀** 400 * For different flame tube lengths, please contact our Technical-Sales Department. K X6/2 EVO - K X7/2 DUAL FUEL GAS/LIGHT-OIL BURNERS AT TWO STAGES SK073566_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel gas/light-oil burners at two stages. DETAILED SPECIFICATION Dual fuel gas/light-oil burners at two stages, composed by: • Die-cast aluminum body; • Fan at high pressurisation, with reverse blades for model K X6/2 EVO; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox blast tube and inox flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Manual switch for the fuel selection gas/light-oil; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Complete with gas train with multiblock valve class A (1st stage + 2nd stage slow opening + safety); valve proving system, gas pressure switch and stabilizer filter; • Motor dedicated for the light-oil pump; it turns on simultaneously to the ignition transformer activation; • Maximum gas pressure switch; • UV probe for flame detection; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier; • Servomotor for air shutter and for the consent of the 2nd stage operation; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive LVD; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MD; • Directive PED (art.4, par.3) 2014/68/EU; • Reference rules: EN676 (gas) - EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible pipes; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps.…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR K X6/2 EVO TL is a dual-fuel gas and light-oil burner designed for industrial heating applications. Operating at 2 stages with a maximum thermal power of 1118 mcal/h and noise level of 82-83 dBA, it delivers efficient combustion across variable load ranges. Suitable for commercial and industrial boiler installations requiring flexible fuel capability.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR K X6/2 EVO TL burner in the Philippines?

3G Electric Philippines sources the FBR K X6/2 EVO TL for delivery to Manila and Quezon City and nationwide. We handle all Bureau of Customs documentation and logistics. Contact us for availability, lead time, and PHP pricing.

What is the lead time for the FBR K X6/2 EVO TL burner?

Lead time depends on current stock and import schedule. Submit your part number (004318_31) and required delivery date to 3G Electric. We manage customs clearance and deliver nationwide to CALABARZON, food processing, and power-generation facilities.

What is the maximum thermal output of the FBR K X6/2 EVO TL?

The FBR K X6/2 EVO TL delivers 1118 mcal/h at full load, operating at 2 stages for modulating combustion across variable loads. It operates on dual fuel (gas/light oil) at 3~400V, 50Hz supply with IP 40 protection rating.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
K X7/M TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/M TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL