We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR FGP 75/2 TL SI - Burners & Combustion
FBRBurners & Combustion

FBR FGP 75/2 TL SI

The FBR FGP 75/2 TL SI is a two-stage diesel burner for light-oil heating applications, delivering 302–949 kW with Low NOx emissions below 120 mg/kWh. It operates on 3~400V power supply and weighs 47 kg, suited for…

SKU 3G-FBR-00072

Brand
FBR
Item
FGP 75/2 TL SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
47 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
250
fan motor w
1.5
power kw max
949
power kw min
302
flow kg h max
80
flow kg h min
25.5
ip protection
IP 40
noisiness dba
78-82.5
pump motor kw
0.37
electrical supply
3
power supply info
3~400V, 1N~230V
current absorption a
0.3
thermal power mcal h
260/408-816
nominal electric power w
1.6
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 LIGHT-OILBURNERSTWOSTAGES FGP 75/2 Burners for light-oil two stages. Complete of air blower with high pressurisation, combustion head with adjustment for high efficiency and high flame stability , with hydraulic system for regulation fo the combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility for easy operations of setting and maintenance. Complete of nozzles, flexible hoses and line filter. Complete of flange and gasket for installation on generator. Fig. 1 FGP 75/2 FGP 75/2 LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 TECHNICAL DATA FGP 75/2 MODEL FGP 75/2 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 17.5/35-80 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 178/357-816 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 207/415-949 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 1.6 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.4 Nominal auxiliary absorption [A] 0.3 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] 78-82.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - 0 (zero) Height meters above mean sea level. ** Sound power level detected at a distance of 1 meter in the combustion lab with burner working on boiler (UNI EN ISO 3746). OPERATING RANGE DIAGRAM FGP 75/2 [bar] 14 FGP 75/2 12 10 8 6 4 2 0 0 10 20 30 40 50 60 70 80 90 [kg/h] Fig. 2 X = Flow Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 75/2 LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 DIMENSIONS [MM] Fig. 3 Dimensions FGP 75/2 MODEL A B C1 C2 D E F G H I O FGP 75/2 187 350 623 1062 165 417 170 300 10 144 18 C2: Overall dimension with the burner out in position of maintenance. * see "flame tube length" FGP 75/2 LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L max M N min N* N max FGP 75/2 mm 310 368 M12 180 180 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 75/2 mm 250 335 ** For different flame lengths, please contact our Technical-Sales Department. FGP 75/2 LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 Fig. 5 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 75/2 LIGHT-OIL BURNERS TWO STAGES SK070084_A_gb_FGP 75_2 PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages. DETAILED SPECIFICATION Light-oil burner two stages composed by: • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE· Directive· M.D.; • 2014/68/UE· (ART.4,PAR.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FGP 75/2
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 75/2 TL SI is a two-stage diesel burner for light-oil heating applications, delivering 302–949 kW with Low NOx emissions below 120 mg/kWh. It operates on 3~400V power supply and weighs 47 kg, suited for industrial and commercial heating systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR FGP 75/2 TL SI diesel burner in the Philippines?

3G Electric Philippines supplies the FBR FGP 75/2 TL SI for delivery to Manila, Quezon City, and CALABARZON. We handle Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for pricing and lead-time on request.

What is the lead time and shipping for the FBR FGP 75/2 TL SI to the Philippines?

Lead time depends on stock availability in our supply chain. 3G Electric manages all logistics and customs clearance to your Philippines location. Exact lead-time provided on quotation request.

What are the key specifications of the FBR FGP 75/2 TL SI burner?

The FBR FGP 75/2 TL SI delivers 302–949 kW with low NOx emissions below 120 mg/kWh. Two-stage modulating control, 3~400V power supply, 47 kg weight, IP 40 protection. Fuel flow: 25.5–80 kg/h light oil.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 75/2 LX TL SI
FBR
FGP 75/2 LX TL SI
FGP 75/2 TC SI
FBR
FGP 75/2 TC SI
FGP 75/2 LX TC SI
FBR
FGP 75/2 LX TC SI
FGP 75/M TL SA
FBR
FGP 75/M TL SA
FGP 160/2 TL SI
FBR
FGP 160/2 TL SI
FGP 190/3 TL SI
FBR
FGP 190/3 TL SI

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL