We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR FGP 75/2 LX TC SI - Burners & Combustion
FBRBurners & Combustion

FBR FGP 75/2 LX TC SI

The FBR FGP 75/2 LX TC SI is a two-stage light-oil diesel burner designed for industrial heating applications with Low NOx emissions below 120 mg/kWh. It delivers 333–1186 kW thermal output with a 250 mm nozzle…

SKU 3G-FBR-00081

Brand
FBR
Item
FGP 75/2 LX TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
250
fan motor w
1.5
power kw max
1186
power kw min
333
flow kg h max
100
flow kg h min
28
ip protection
IP 40
noisiness dba
82-83.6
pump motor kw
0.37
electrical supply
3
power supply info
- 50Hz
current absorption a
0.82
thermal power mcal h
286.4/510-1020
nominal electric power w
2.1
max combustion air temp c
60

Datasheet Content

SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO FGP 75/2 LX - FGP 100/2 LX EVO Burners for light-oil two stages - Low NOx (NOx < 120 mg/kWh). Composed by die-cast aluminum body, an at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of flange and gasket for installation on generator, nozzles, flexible pipes, line filter. Fig. FGP 100/2 LX EVO FGP 75/2 LX - FGP 100/2 LX EVO SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO TECHNICAL DATA FGP 75/2 LX - FGP 100/2 LX EVO MODEL FGP 75/2 LX FGP 100/2 LX EVO Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 25.5/40-80 28/50-100 Thermal power min. 1°st. / min. 2°st. -max. 2°st. * [Mcal/h] 260/408-816 286.4/510-1020 Thermal power min. 1°st. / min. 2°st. -max. 2°st. * [kW] 302/474-949 333/593-1186 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 1.6 2.1 Fan motor [kW] 1.5 1.5 Pump motor [kW] - 0.37 Nominal fan motor current absorption [A] 3.4 4.5 Nominal pump motor current absorption [A] 0.3 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness ** min-max [dBA] 78-82.5 82-83.6 Average NOx , EN267:2020. [mg/ 99.4 93.1 kWh] NOx Class 3 3 Burner weight *** [kg] 47 52 * Reference conditions:Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 3 kg. FGP 75/2 LX - FGP 100/2 LX EVO SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO OPERATING RANGE DIAGRAM FGP 75/2 LX 12 FGP 75/2 LX 10 8 6 4 2 0 200 300 400 500 600 700 800 900 1000 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. OPERATING RANGE DIAGRAM FGP 100/2 LX EVO 14 13 FGP 100/2 LX EVO 12 11 10 9 8 7 6 5 4 3 2 1 0 ‐1 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/2 LX - FGP 100/2 LX EVO SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO DIMENSIONS [MM] Fig. Dimensions FGP 75/2 LX MODEL A B C1 C2 D E F G H I O FGP 75/2 LX 187 350 623 1062 165 417 170 300 10 144 18 C2: Overall dimension with the burner out in position of maintenance. TC - TL: see "flame tube length" FGP 75/2 LX - FGP 100/2 LX EVO SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO G F H C E A B TC - TL D Fig. Dimensions FGP 100/2 LX EVO MODEL A B C D E F G H FGP 100/2 LX EVO 411 294.5 175 766.5 510 140 290 280 TC - TL: see "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max FGP 75/2 LX mm 310 368 M12 180 180 250 FGP 100/2 LX EVO mm 275 325 M10 185 185 220 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 75/2 LX mm 250 335 FGP 100/2 LX EVO mm 235 370 ** For different flame lengths, please contact our Technical-Sales Department. FGP 75/2 LX - FGP 100/2 LX EVO SK070098_A_en LIGHT-OIL BURNERS TWO STAGES (LX SERIES) MOD: FGP 75/2 LX FGP 100/2 LX EVO BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 75/2 LX - FGP 100/2 LX EVO…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 75/2 LX TC SI is a two-stage light-oil diesel burner designed for industrial heating applications with Low NOx emissions below 120 mg/kWh. It delivers 333–1186 kW thermal output with a 250 mm nozzle, weighing 52 kg, and operates at IP 40 protection for robust industrial combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR FGP 75/2 LX TC SI diesel burner in the Philippines?

3G Electric Philippines is your supplier. We handle delivery to Manila and Quezon City, plus all logistics and Bureau of Customs documentation. Lead time on request—contact us for quotation and stock confirmation.

What is the thermal output range of the FBR FGP 75/2 LX TC SI?

The FBR FGP 75/2 LX TC SI delivers 333–1186 kW thermal output in two-stage modulating mode. Maximum fuel flow is 100 kg/h; minimum is 28 kg/h. It operates on 50 Hz, three-phase electrical supply.

What are the emissions and noise specifications?

NOx emissions are below 120 mg/kWh (Low NOx series). Noise level ranges 82–83.6 dBA. The burner is IP 40 rated, weighs 52 kg, and features a 250 mm nozzle for robust industrial combustion systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 75/2 LX TL SI
FBR
FGP 75/2 LX TL SI
FGP 75/2 TC SI
FBR
FGP 75/2 TC SI
FGP 75/2 TL SI
FBR
FGP 75/2 TL SI
FGP 75/M TC SA
FBR
FGP 75/M TC SA
FGP 160/2 LX TC SI
FBR
FGP 160/2 LX TC SI
FGP 75/M TL SA
FBR
FGP 75/M TL SA

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL