FBR FGP 100/2 TL EVO SI

The FBR FGP 100/2 TL EVO SI is a two-stage light-oil burner designed for industrial heating applications, delivering 333–1,186 kW with low NOx emissions under 120 mg/kWh. Operating at 50 Hz with IP 40 protection, it…

SKU 3G-FBR-00070

Brand
FBR
Item
FGP 100/2 TL EVO SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
250
fan motor w
1.5
power kw max
1186
power kw min
333
flow kg h max
100
flow kg h min
28
ip protection
IP 40
noisiness dba
82-83.6
pump motor kw
0.37
electrical supply
3
power supply info
- 50Hz
current absorption a
0.82
thermal power mcal h
286.4/510-1020
nominal electric power w
2.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES SK070084_B_en FGP 100/2 EVO Light-oil burners two stages. Composed by: fan at high pressurisation at reverse blades, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Fig. 1 FGP 100/2 EVO FGP 100/2 EVO LIGHT-OIL BURNERS TWO STAGES SK070084_B_en TECHNICAL DATA FGP 100/2 EVO MODEL FGP 100/2 EVO Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 21.8/40-100 Thermal power min. 1°st. / min. 2°st. -max. 2°st. * [Mcal/h] 222.4/408-1020 Thermal power min. 1°st. / min. 2°st. -max. 2°st. * [kW] 258.6/474.4-1186 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation/storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max temperature combustion air [°C] 60 Nominal electric power [kW] 2.1 Fan motor [kW] 1.5 Pump motor [kW] 0.37 Nominal fan motor current absorption [A] 3.3 Nominal pump motor current absorption [A] 1.2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dB(A)] 82-83.6 Burner weight *** [kg] 52 * Reference conditions:Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 2 kg. OPERATING RANGE DIAGRAM FGP 100/2 EVO [mbar] 15 14 FGP 100/2 EVO 13 12 11 10 9 8 7 6 5 4 3 2 1 0 ‐1 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 100/2 EVO LIGHT-OIL BURNERS TWO STAGES SK070084_B_en DIMENSIONS [MM] G F H C E A B TC - TL D Fig. 3 Dimensions FGP 100/2 EVO MODEL A B C D E F G H FGP 100/2 EVO 411 294,5 175 766,5 510 140 290 280 * see "flame tube length" FGP 100/2 EVO LIGHT-OIL BURNERS TWO STAGES SK070084_B_en BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L max M N min N* N max FGP 100/2 EVO mm 275 325 M10 185 185 220 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 100/2 EVO mm 235 370 ** For different flame lengths, please contact our Technical-Sales Department. FGP 100/2 EVO LIGHT-OIL BURNERS TWO STAGES SK070084_B_en BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 Fig. 5 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 100/2 EVO LIGHT-OIL BURNERS TWO STAGES SK070084_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages. DETAILED SPECIFICATION Light-oil burner two stages composed by: • Fan at high pressurisation at reverse blades; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Safety air pressure switch to stop the burner in lock-out (by stopping the pump motor) in case of failed or anomalous fan operation; • Dedicated motor for the activation of the light-oil pump. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • Directive PED 2014/68/UE (ART.4,PAR.3); • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FGP 100/2 EVO
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 100/2 TL EVO SI is a two-stage light-oil burner designed for industrial heating applications, delivering 333–1,186 kW with low NOx emissions under 120 mg/kWh. Operating at 50 Hz with IP 40 protection, it suits mid-range commercial and industrial combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I order the FBR FGP 100/2 TL EVO SI burner in the Philippines?

Order directly from 3G Electric Philippines. We handle delivery to Manila and Quezon City, manage Bureau of Customs documentation, and arrange logistics to your facility. Lead time on request — contact our sales team for availability and PHP invoicing.

What is the power output range and NOx specification?

The FGP 100/2 TL EVO SI delivers 333–1,186 kW in two-stage modulating mode. It meets Low NOx emissions of less than 120 mg/kWh, ideal for food processing and industrial heating in CALABARZON plants requiring clean combustion compliance.

What are the operating conditions and electrical requirements?

Operates at 50 Hz with IP 40 protection. Requires three-phase electrical supply with 0.82 A current absorption. Weighs 52 kg; suitable for mid-range commercial and industrial systems. Available to order through 3G Electric Philippines.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 100/2 LX TL EVO SI
FBR
FGP 100/2 LX TL EVO SI
FGP 100/2 TC EVO SI
FBR
FGP 100/2 TC EVO SI
FGP 130/2 TL EVO SI
FBR
FGP 130/2 TL EVO SI
FGP 100/2 LX TC EVO SI
FBR
FGP 100/2 LX TC EVO SI
FGP 50/2 TL EVO 3 SI
FBR
FGP 50/2 TL EVO 3 SI
FGP 130/2 TC EVO SI
FBR
FGP 130/2 TC EVO SI

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL