DTekGaz Detection unit 3 probes - Gas Detection
DTekGazGas Detection

DTekGaz Detection unit 3 probes

DTekGaz GS300-Mc is a three-zone gas detection unit for industrial facilities monitoring toxic, explosive gases, and oxygen. It supports one to four remote probes with IP44 enclosure rating. Alarm thresholds set at…

SKU 3G-CBM-02003

Also listed as: DTK 08004 · DTK-08004

Brand
DTekGaz
Item
Detection unit 3 probes
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DTekGaz
model
GS300-Mc
zones
3 conventional
probes
1 to 4 remote probes
gas detection
Toxic, explosive gases and oxygen
enclosure rating
IP44
alarm 1 threshold
8% LEL (120 ppm)
alarm 2 threshold
13% LEL (200 ppm)
general alarm threshold
20% LEL (300 ppm)

Datasheet Content

Centrale de détection gaz modulaire GS300-Mc 3 zones conventionnelles 3G-CBM-02003 V6 La NOUVELLE centrale GS300-Mc a été projetée à partir de la version précédente pour détecter de manière polyvalente les éventuelles fuites de gaz dans le domaine industriel. Grâce à la possibilité de connecter de 1 à 4 sondes à distance, elle détecte la présence de gaz toxiques et/ou explosifs et oxygène. La présence det d’autres perspicacités rendent la centrale apte pour les applications industrielles et terzaires. La centrale est dotée d'un afficheur à partir duquel: a) Lire le temps d'attente (chauffage) b) La concentration de gaz détectée par chaque sonde c) L'affichage de la sonde est en cours de lecture d) Afficheur approprié de détection d'oxygène e) Le contrôle de la sonde éventuellement en panne La GS300-Mc présente quatre niveaux de danger qui sont: 1° Alarme est fixée pour toutes les sondes à 8 % de la L.I.E. (120ppm) 2° Alarme est fixée pour toutes les sondes à 13 % de la L.I.E. (200ppm) 3° Alarme générale est fixée à 20 % de la L.I.E. (300ppm) 4° Alarme, dédiée à la détection de l'oxygène pour <carence en oxygène et> excès en oxygène. D’autres éléments rendent cette centrale extrêmement polyvalente et fiable par exemple avec une série de micro-interrupteurs il est possible de: Sélectionner ou supprimer la sonde qui n’est pas installée ou qui est en panne Sélectionner le type de gaz à détecter: toxique ou explosif Choisir le fonctionnement du relais: en mode continue ou en impulsion Choisir d’activer ou de désactiver la sécurité positive. La GS300-Mc a le prérequis pour pouvoir tester de deux façons différentes: 1) Test du système. En tenant appuyé sur le bouton de test, vous testez que tout le système fonctionne y compris les relais et les accessoires qui y sont connectés. 2) TEST d’entretien. Avec les éléments appropriées (voir page 8) on peut activer la fonction d'exclusion du relais d'alarme générale pour une durée maximale de 60 minutes. La structure extérieure IP44 a été étudiée pour etre installée au mur ou avec ses propres supports, dans des armoires électriques. Outre le signal lumineux d’alarme, il est prévu un buzzer (vibreur) à l’intérieur. Important: Les opérations de montage/entretien de l'appareil doivent être effectuées par un personnel qualifié conformément aux lois et les normes en vigueur. Le constructeur n'assume aucune responsabilité quant à l'utilisation des produits qui doivent se conformer aux normes environnementales. Note importante Avant de brancher l'appareil, il est recommandé de lire attentivement la notice technique et de la conserver pour une utilisation ultérieure. Il est également recommandé d'effectuer correctement les branchements électriques selon les schémas inclus en respectant les consignes de sécurité et les normes. N.B. Consulter la notice technique dans tous les cas où le symbole à côté est présent CONFORMITÉ EN 50194  Notice technique EN 45544-1-3 EN 50270 EN 61010-1 Conforme EN 60079-29-1 INSTALLER DANS UNE Installation EN 60079-29-2 installation/emploi ZONE SÉCURITAIRE Rapport délivré par TUV Italia NON ATEX Guide branchement électrique aussi sur Précautions S’ASSURER de l’intégrité de la centrale après l’avoir retirée de sa confection. Vérifiez que les descriptions sur la boîte soient correspondantes au type de gaz et de la tension électrique utilisée. Suivre attentivement le schéma lorsqu’on effectue le branchement électrique. Nous déclinons toute responsabilité pour des dommages causés à des personnes, animaux ou choses pour n’importe quel usage inapproprié pour laquelle la centrale a été projetée. TERMES ET FIABILITÉ: l’installation de la centrale, son entretien ordinaire et extraordinaire qui doivent s’effectuer une (1) fois par an et la mise au rebut à la fin de la période de fonctionnement garantie par le constructeur ne doivent être effectués que par un personnel autorisé et spécialisé. IMPORTANT: les tests de fonctionnement ne doivent pas être effectuée avec le robinet du gaz puisque ceci ne garantit pas une concentration suffisante pour déclencher l’alarme générale. Pour utiliser avec satisfaction pour une longue période votre centrale numérique, utilisez-la en suivant les précautions : Ne pas mettre en contact avec de l’eau. La centrale n’est pas imperméable et si elle est plongée dans l’eau ou exposée à des taux d’humidité élevée elle peut rapporter de sérieux dommages. Ne pas faire tomber. Des forts coups ou des chutes pendant le transport ou l’installation peuvent endommager l’a ppareil. Évitez des brusques baisses de température. Des brusques variations de température peuvent provoquer la formation de condense et la centrale pourrait ne pas bien fonctionner. Nettoyage. Ne jamais nettoyer l’appareil avec des produits chimiques. Si nécessaire utilisez un chiffon humide. ENTRETIEN •L'utilisateur périodiquement (tous les 6 mois), doit procéder à une vérification du fonctionnement de la centrale en pulvérisant du gaz de test à la base des sondes connectées jusqu'à déclencher l'alarme • Au moins une fois par an, faire un contrôle plus précis par un technicien qualifié. • La mise au rebut de la centrale doit être effectuée par un personnel qualifié. Caractéristiques Techniques Alimentation Primaire ..............................................................................110/240VAC 50/60 Hz ± 10% Alimentation secondaire par batterie Max 2.2 Ah (facutatif) ........................................ 12 VDC ± 10% Charge batterie Max 2.2 Ah ........................................................................................................ contrôlée Consommation ...........................................................................................................8,3 W Max @ 230VAC Consommation ..............................................................................................................4 W Max @ 12VDC Capacité des contacts sur relais ....................................................... 10A 250VAC résistif 5A 30VAC résistif 1° Pré-alarme...........................................................................…....fixée à 8% de la L.I.E ou 120 ppm CO 2° Pré-alarme ............................................................................... fixée à 13% de la L.I.E ou 200 ppm CO Alarme finale ................................................................................ fixée à 20% de la L.I.E ou 300 ppm CO Alarme d'oxygène ............< Carence en oxygène, > Excès d'oxygène ...................... voir les seuils page 5 Signalisation du gaz détecté ............................................................ par affichage rétro-éclairé en couleurs Sondes conventionnelles connectées ............................................................................................Max 3 Micro interrupteurs pour inclure/exclure les sondes ...................................................... 1 pour chaque zone Micro interrupteurs pour sélectionner la détection d'oxygène ............................................................. incorporés Sondes compatibles .... Semi-conducteur, Catalytique, Cellule Électrochimique, Pellistor, fluorescence optique Pannes détectées par le circuit de défaut ......................................... Interruption, court circuit ou décadence Signal d’entrée .................................................................................................. 4 ÷ 20 mA sur 220 Ohm Temps de réponse ................................................................................................................. < 2 secondes Précision de l’appareil ............................................................................................................... 1% FS Température de fonctionnement ................................................................................... -10 °C ÷ + 60 °C Durée phase d’attente clignotante ..............................................................................................90 secondes Test manuel ............................................................................................................................... incorporé Distance maximum entre les sondes et la centrale........................................................................ 100 m Diamètre des câbles de branchement aux sondes........................................................................ 1 mm2 Connexion: les câbles de connexion de la sonde ne doivent pas être posées ensemble avec ceux de la puissance. Si on pose ensemble les câbles de connexion et ceux de la puissance, il faut utiliser un câble blindé. Dimensions .................................................................................................................... DIN 144x144x108 Dégré de protection ....................................................................................................................... IP44 ATTENTION ! mesures à prendre en cas d’alarme 1) Éteindre toutes les flammes . 2) Fermer le robinet principal du gaz ou de la bouteille de GPL. 3) Ne pas allumer ou éteindre aucune lumière , ne pas démarrer aucun appareil ou dispositif alimenté él ectri quement 4) Ouvrir toutes les portes et les fenêtres afin d’aérer les lieux. Si l’alarme cesse il est nécessaire d’identifier les causes et de pourvoir par conséquent. Si l’alarme continue et les causes de la fuite de gaz e sont pas localisées et éliminées, abandonner les lieux et avertir les services d’émergence (les sapeurs-pompiers, les distributeurs, etc). IMPORTANT: Le test ne doit pas être effectué avec le robinet du gaz car cela ne garantit pas une concentration suffisante de gaz pour activer l'alarme. Attention ! ! Si on a des symptômes de vomissements, de somnolence ou autre malaise, se rendre subitement aux urgences les plus proches en avertissant le médecin de garde que la cause peut être un intoxication de Monoxyde de carbone, ou par excès ou carence d'OXYGÈNE Page 2 Sondes adaptables par zone et type de gaz So nde CAPTEUR DEGRÉ Apte pour GAZ PLAGE SORTIE PRECIS. ETALONNAGE RELAIS Protect. ZONE Détecté Mesure Automatique SG500 Ca ta ly tiqu e IP30 Domestique CH4-GPL 0÷100% LIE 4÷20 mA ±5 % NON NON SG544 Ca ta ly tiqu e IP44 Tertiaire CH4-GPL 0÷100% LIE 4÷20 mA ±5 % NON NON SGM595 Ca ta ly tiqu e IP55 Tertiaire Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI NON SGM595/A Ca ta ly tiqu e IP66 Zone 2 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI NON SGM533 Ca ta ly tiqu e IP55 Tertiaire Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI OUI SG800 Ca ta ly tiqu e IP66 Zone 2 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI OUI HCF100 Semi-conduct…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DTekGaz Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DTekGaz GS300-Mc is a three-zone gas detection unit for industrial facilities monitoring toxic, explosive gases, and oxygen. It supports one to four remote probes with IP44 enclosure rating. Alarm thresholds set at 8% LEL (120 ppm), 13% LEL (200 ppm), and general alarm at 20% LEL (300 ppm) for comprehensive hazard coverage.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the DTekGaz GS300-Mc gas detection unit in the Philippines?

3G Electric Philippines stocks and sources the DTekGaz GS300-Mc for delivery to Manila, Quezon City, and nationwide. We handle Bureau of Customs documentation, PHP invoicing, and logistics. Contact us for lead time and quote on this three-zone detection unit.

What is the lead time for ordering a DTekGaz GS300-Mc detector?

Lead time varies based on current availability. 3G Electric will provide a confirmed shipping date upon order. Delivery to the Philippines includes full customs clearance and documentation support. Request a quote for fastest processing.

How many probes does the DTekGaz GS300-Mc support and what gases does it detect?

The GS300-Mc three-zone unit supports 1 to 4 remote probes. It detects toxic gases, explosive gases (8% LEL at 120 ppm, 13% LEL at 200 ppm, general alarm 20% LEL at 300 ppm), and oxygen. IP44 enclosure rating protects against industrial environments.

Used in

Common applications for DTekGaz
Petrochemical plants — DTekGaz ATEX SG895 catalytic sensor probes monitor explosive gas concentrations in confined tanks and process vessels
Refrigeration and HVAC maintenance — DTekGaz HCF100 semiconductor probe detects R407C, R410A, and R32 leaks during service and commissioning
Industrial hazardous areas — DTekGaz extension card relay outputs interface with plant PLC/DCS systems to trigger alarms and emergency shutdowns
Portable field detection — DTekGaz 12 V rechargeable battery and metal-housed hydrogen/butane probes support temporary site surveys and confined-space entry
Fixed control room installations — DTekGaz 24 VDC audible alarm and extension modules provide centralized monitoring of multiple distributed sensor probes
Water treatment and biogas plants — DTekGaz catalytic and semiconductor probes detect methane, hydrogen sulfide, and other hazardous gas byproducts

DTekGaz Products

3G Electric supplies DTekGaz gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Detection unit 4 probes
DTekGaz
Detection unit 4 probes
Detection unit 1 probe
DTekGaz
Detection unit 1 probe
Detection center 16 probes
DTekGaz
Detection center 16 probes
Gas detection central unit Din rail 2 probes
DTekGaz
Gas detection central unit Din rail 2 probes
DTekGaz
DTekGaz
Gas detection center Din rail 4 probes
DTekGaz
DTekGaz
3S GN Probe

More from DTekGaz

View all DTekGaz parts
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
DTekGaz
R134A gas probe
DTekGaz
DTekGaz
Battery 12V - 2.2Ah
DTekGaz
DTekGaz
CO2 probe metal housing IP66
DTekGaz
DTekGaz
Probe for R32 gas
DTekGaz
DTekGaz
Probe for R404 gas
DTekGaz
DTekGaz
Central detection box DIN rail small IP 65
DTekGaz
DTekGaz
Valve for 1liter bottle