We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Supco Megohmmeter - HVAC Equipment
SupcoHVAC Equipment

Supco Megohmmeter

The Supco M500 is a handheld insulation tester for HVAC equipment diagnostics, applying 500 volts across a 20 to 1000 Megohms measurement range. LED display and dual C-battery power enable field troubleshooting of…

SKU 3G-CBM-01287

Also listed as: COP 14004 · COP-14004

Brand
Supco
Item
Megohmmeter
Category
HVAC Equipment
UNSPSC
40101709 — Air handling unit
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Supco
model
M500 Insulation Tester
display
LEDs
power source
2 C-size batteries
applied voltage
500 volts
dimensions inches
3-3/8" x 6-3/8" x 1-3/4"
measurement range
20 to 1000 Megohms

Datasheet Content

HARD STARTING AND OVERLOAD PROBLEMS: SPECIFICATIONS Range 20 to 1000 MegOhms M500 MEGOHMMETER Applied Voltage 500 Volts Answering a call where the problem is a hard-starting Power Source (2) “C” Size Batteries condition is more involved than merely replacing a Test Leads (2) 9” Long (Store within case) defective relay, start capacitor, or installing a hard start. The unknown factor is how long did the unit cycle on the overload before the consumer realized the food compartment was getting warm and called OPERATION the service dispatcher. In other words, was the wind- 1. Install two new alkaline “C” size batteries. Polarity is ing overheated to a point that could have damaged indicated on bottom of battery compartment. the insulation? This unknown factor of overheated 2. Remove ALL wires that are connected to the terminals windings is also present on calls that relate to dirt- that are to be tested. Attach one test lead from the meg- clogged condensers, defective condenser fan bearings Ohmmeter to ANY WINDING TERMINAL and the other test or motors and brownouts. Whenever a sustained motor lead to the METAL CASE of the motor. Make sure the point of overload condition existed before you arrived on the contact is clean to the BARE METAL (no paint). job site, a megOhmmeter test tells both you and the 3. Depress “POWER” button, wait approximately 10 seconds consumer if there was any damage to the winding then proceed to read the insulation value shown on the cor- insulation. Putting this information on the consumer’s responding illuminated LED lamp. receipt and recording it in the office records is sound 4. Illuminated “BELOW 20” lamp indicates low insulation or a business practice for any future problems and assures short circuit in the unit being tested. the customer that the service engineer “KNOWS HIS 5. If the “ON” lamp is illuminated but no light appears on the BUSINESS”. megOhm scale, then the insulation value is MORE THAN 1000 MEGOHMS. APPLICATION 6. If the “ON” light is not illuminated when the “POWER” button is depressed, then the batteries are installed improp- Hermetic Refrigeration Motors erly or the batteries are weak and should be replaced. 7. Remember, all tests are made from the motor Hermetic motors require special test parameters since TERMINAL to the METAL CASE. the winding operates in an oil and refrigerant atmo- sphere. Under normal conditions the oil and refriger- ant have a high electrical resistance. However, when Why All HVAC/R they are contaminated with moisture, the electrical resistance changes and a low megOhm reading of the winding terminal to ground may actually be the resistance of the contaminants in the oil and not in the winding insulation. New hermetic motors have a Service Technicians resistance value of more than 100 megOhms. Readings of 50 megOhms or less would indicate that either the Need This Instrument winding insulation is deteriorating or the oil/refrig- erant is contaminated. Installing an oversized drier may clean up the system or another possible solution could be replacing all the compressor oil. In either You have often heard the expression, “THE MOTOR case, if the megOhm tests show even the slightest IS BURNT OUT” or “THE MOTOR IS HALF COOKED” improvement in resistance values, the remedy may or “IT WAS OVERHEATED”. Actually, the reference is have checked a declining condition. A good “rule of F583 being made to the condition of the motor winding thumb” is to smell a small sample of the oil. If at any 09092015 insulation... time in the history of the unit the motor was severely overloaded, it will leave a tell-tale trace in the oil that can never be removed other than by discharging SEALED UNIT PARTS CO., INC. all refrigerant and replacing oil. The odor of burnt PO Box 21, 2230 Landmark Place insulation is easily recognized and a low resistance Allenwood, NJ 08720 USA value of 20 megOhms or less will verify that the motor www.supco.com insulation may be severely damaged. www.supco.com The wire itself is rarely, if ever, destroyed. It is always 100-200 MegOhms 20-60 MegOhms the motor-winding insulation that determines if the motor Readings Readings is good, bad, or on the verge of becoming bad. The winding insulation prevents the current, which is going through the Most electrical engineers and motor designers agree A 0 to 60 megOhms reading in a hermetic compres- wire, from traveling into the motor body. The expression, that a measurement of 150 or more megOhms across sor is an indication that you can have any one of “THAT MOTOR IS GROUNDED” simply means that the insula- an electrical terminal to its ground would be consid- a few problems; a winding that was overheated, tion of the winding has deteriorated or has become damaged ered excellent insulation, and a reading of 100 to 150 contaminated oil, or moisture circulating in the from heat and can no longer resist the current from traveling megOhms is very good. system. Sampling the oil for a burning odor will tell into the motor body. You can TEST the resistance of the insu- you immediately that the winding was overheated. lation, or you can MEASURE the resistance of the insulation. If the oil is clean and odor free, it can still have some contamination that is causing the low megOhm THERE ARE TWO WAYS OF reading. A 20 megOhm reading shows severe contam- ination and failure of the system is likely. The best TESTING THE INSULATION: overall protective procedure is to dump and replace all the oil and change and install a new liquid line 1. A high voltage test from wire to ground (motor body). 2. A high voltage breakdown test from wire to ground. A drier. If the oil had an odor, a thorough check of the high voltage test is usually performed at the factory where condensing medium, air fans, cooling tower and all the product is manufactured. The Underwriters Labora- motors for worn bearings should be made. Now that tory standard is to test an electrical product from wire you have discovered a low megOhm reading and have to ground with a voltage equal to 1,000 plus twice the taken the necessary preventative measures, the operating voltage, as an example: If a motor was operating follow-up is very important. Take another reading in at 115VAC, you would conduct the test at 230VAC from wire a few weeks, and if the reading remains the same to ground and measure if there was any current going into or improves, take another measurement in a few the body. A high voltage breakdown test is performed to months. If the reading shows more deterioration, determine at what voltage point the insulation will break you can forewarn the owner that there is going to down and allow current to pass into the motor body. Since be a major breakdown in their system. One of the you are actually destroying the insulation, a breakdown test 60-100 MegOhms best maintenance programs for a new system is to log the megOhmmeter readings when the unit is first is usually performed in a laboratory where different insula- tions are being tested for their resistance to high voltage, Readings installed and compare the readings every six months. or a more technical term, dielectric strength. The two Measurements of 60 to 100 megOhms would show a above methods are used to TEST the insulation resistance. decline in the insulation resistance, either in an area or a specific spot. This is a most important measure- MEASURING THE ment. It tells you that if you do not take corrective steps, the insulation will completely breakdown. INSULATION RESISTANCE: With open type motors it is a matter of good house- keeping by cleaning the dust and any grime from the Since the measurement of electrical resistance is the OHM, windings, using a recommended solvent. we use an Ohmmeter. When measuring the insulation re- sistance of a motor winding, we are involved in resistances in the range of 50 to 100 million ohms. As…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Supco Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Supco M500 is a handheld insulation tester for HVAC equipment diagnostics, applying 500 volts across a 20 to 1000 Megohms measurement range. LED display and dual C-battery power enable field troubleshooting of compressor windings and motor circuits.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Supco M500 megohmmeter in the Philippines?

3G Electric Philippines supplies the Supco M500 insulation tester with delivery to Manila and Quezon City. We handle all logistics and Bureau of Customs documentation. Contact us for availability and lead time on request.

What is the measurement range of the Supco M500?

The Supco M500 measures insulation resistance from 20 to 1000 Megohms at 500 volts applied voltage, ideal for compressor windings and motor circuit diagnostics in HVAC systems.

How is the Supco M500 powered in the field?

The M500 runs on two C-size batteries, enabling portable field testing without external power. The LED display provides clear readings during HVAC equipment troubleshooting.

Used in

Common applications for Supco
Commercial refrigeration display cases — Supco RO82 relay and CSS-25U starter for compressor motor control without run capacitors
Medium-load HVAC systems — Supco SPP 6/SPP 8 hard-start devices to reduce compressor inrush current and extend motor lifespan
Cold-chain pharmaceutical and food storage — SL300TH temperature–humidity data logger for continuous monitoring and regulatory documentation
Refrigerant service operations — Piercing valves and perforator cocks in 1/2" and 5/8" sizes for fast, non-invasive line access
Compressor thermal management — Universal Compressor Door for reducing shell temperature and improving efficiency in hot ambient conditions
Retrofit and field repairs — Supco controls with Quick Connect terminals for rapid installation in legacy refrigeration circuits

Supco Products

3G Electric supplies Supco hvac equipment. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Supco
Supco
Digital impedance tester
Electronic manometer DDM55
Supco
Electronic manometer DDM55
Differential thermometer
Supco
Differential thermometer
Thermometer and humidity
Supco
Thermometer and humidity
Sound level meter
Supco
Sound level meter
Thermometer and anemometer
Supco
Thermometer and anemometer

More from Supco

View all Supco parts
Supco
Supco
Axial fan motor D.350 380V THREE-PHASE
CSS-32U 32A starting module
Supco
CSS-32U 32A starting module
Supco
Supco
Axial fan motor D.350 230V single phase with square plate
Supco
Supco
Axial fan motor D.500 380V three-phase with square plate
Supco
Supco
Axial fan motor D.630 230V single-phase with square plate
Supco
Supco
Axial fan motor D.300 380V 3-PHASE
Supco
Supco
Telescopic thermometer -50..+300°C L.max:914mm
Supco
Supco
Axial fan motor D.400 230V single-phase with square plate