We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Allanson 2729-576 Ferromagnetic Transformer - Ignition Transformers
AllansonIgnition Transformers

Allanson 2729-576 Ferromagnetic Transformer

The Allanson 2729-576 is a ferromagnetic ignition transformer from the Small Can Series, designed for 220V input at 50Hz with a secondary voltage of 10000 Volts and 23mA current. It features a zinc-plated button HV…

SKU 3G-OTH-03138

Also listed as: 2729576 · 2729 576

Brand
Allanson
Item
2729-576 Ferromagnetic Transformer
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Current
23mA
Can Size
Small Can Series
Grounding
Mid Point Ground
Hv Terminal
Zinc Plated Button
Input Voltage
220V
Hinge Location
Special Side Hinge
Input Frequency
50Hz
Secondary Voltage
10000 Volt

Datasheet Content

[{"filename":"FerromagneticDP_SpecSheet_21-4141121.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 2721 / 2744 / 2730 / 2714 / 421 / 444 / 911 / 912\n SPECIFICATION GUIDE\n\n\n DOUBLE POLE, MID POINT GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial oil applications.\n\n\n Absolute Maximum Ratings\n Model # 2721, 421* 2744, 444* 911* 2730, 912* 2714\n Rated Operating Input Voltage (V) 120 240 240 120 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132 108-132\n Input Supply Frequency (Hz) 60 60 50 50 60\n Primary Voltage - Amperes (VA) 250 250 250 250 275\n Secondary Voltage (RMS) 10,000 10,000 10,000 10,000 12,000\n Secondary Short Circuit Current (mA) 23 23 23 23 20\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90 90\n Loading Air Gap (inches) 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16\n\n * Service replacement transformers are available in select models.\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 99 Adams Blvd., Farmingdale, New York 11735 #21-414\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Allanson 2729-576 is a ferromagnetic ignition transformer from the Small Can Series, designed for 220V input at 50Hz with a secondary voltage of 10000 Volts and 23mA current. It features a zinc-plated button HV terminal, mid-point grounding, and a special side hinge. 3G Electric interprets customer demand and delivers this genuine industrial component across 14 departments, with specialist depth in combustion, pumps, and controls as an authorised distributor.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 2729-576 ferromagnetic transformer used for?

The Allanson 2729-576 ferromagnetic transformer is designed for constant-duty ignition in commercial and industrial oil burners. It provides a reliable 10,000 V secondary voltage at 23 mA for spark ignition in oil-fired heating systems.

What are the specifications of the Allanson 2729-576 transformer?

The Allanson 2729-576 is a small-can ferromagnetic transformer with 220 V input at 50 Hz, 10,000 V secondary, 23 mA secondary current, and mid-point grounding. It features a zinc-plated button HV terminal and a special side hinge.

Where to buy the Allanson 2729-576 in Singapore?

3G Electric supplies the Allanson 2729-576 ferromagnetic transformer to Singapore. We source and deliver this industrial ignition transformer, handling logistics and customs clearance for your order.

How to install the Allanson 2729-576 transformer?

Install the Allanson 2729-576 by mounting it securely and connecting the 220 V input to the primary terminals. Ensure the mid-point ground is properly bonded. Follow standard oil-burner wiring practices and verify the 1/8 to 3/16 inch air gap for reliable ignition.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 2729-068 Ferromagnetic Transformer
Allanson
Allanson 2729-068 Ferromagnetic Transformer
Allanson 2729-362A Ferromagnetic Transformer
Allanson
Allanson 2729-362A Ferromagnetic Transformer
Allanson
Allanson
Allanson 2729-252A Ferromagnetic Transformer
Allanson 2721-576 Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-576 Ferromagnetic Ignition Transformer
Allanson 2729-628 Ferromagnetic Ignition Transformer
Allanson
Allanson 2729-628 Ferromagnetic Ignition Transformer
Allanson 2721-680 Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-680 Ferromagnetic Ignition Transformer

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne