Allanson 542-GP Ferromagnetic Ignition Transformer for Gordon Piatt - Ignition Transformers
AllansonIgnition Transformers

Allanson 542-GP Ferromagnetic Ignition Transformer for Gordon Piatt

Allanson’s Single Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial gas applications.

SKU 3G-OTH-03302

Also listed as: 542GP · 542 GP

Brand
Allanson
Item
542-GP Ferromagnetic Ignition Transformer for Gordon Piatt
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Poles
Single
Current
23mA
Grounding
One End Ground
Application
GAS
Burner Type
GORDON PIATT
Hv Terminal
1/4-20 Stud
Junction Box
INTERNAL
Input Voltage
120V
Input Frequency
60Hz
Secondary Voltage
10000V
Burner Manufacturer
GORDON PIATT

Datasheet Content

[{"filename":"FerromagneticSP_SpecSheet_21-3101121.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 1092 / 1112 / 1196 / 542\n SPECIFICATION GUIDE\n\n\n SINGLE POLE, ONE END GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial gas applications.\n\n\n Absolute Maximum Ratings\n Model # 1092 1112 1196 542\n Rated Operating Input Voltage (V) 120 240 240 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132\n Input Supply Frequency (Hz) 50/60 60 50 60\n Primary Voltage - Amperes (VA) 250/180 180 180 265\n Secondary Voltage (RMS) 6000 6000 6000 10000\n Secondary Short Circuit Current (mA) 25/20 20 20 23\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90\n Loading Air Gap (inches) 1/16 - 1/8 1/16 - 1/8 1/16 - 1/8 1/16 - 1/8\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 181 Cooper Ave., Suite 112, Tonawanda, NY 14150 #21-310\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Allanson’s Single Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial gas applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03302 ignition transformer used for?

The Allanson 3G-OTH-03302 ferromagnetic ignition transformer provides a reliable ignition source for commercial, residential, and industrial gas applications. It is specifically designed for Gordon Piatt burners, delivering a 10000V secondary voltage at 23mA to ensure consistent spark ignition in gas-fired equipment.

What are the specifications of the Allanson 3G-OTH-03302?

The Allanson 3G-OTH-03302 is a single-pole, one-end ground transformer with a 120V input voltage at 60Hz. It delivers a secondary voltage of 10000V RMS and a secondary short circuit current of 23mA. The operating temperature range is -30 to +40 °C, and it features an internal junction box with a 1/4-20 stud HV terminal.

Where to buy the Allanson 3G-OTH-03302 in Singapore?

You can source the Allanson 3G-OTH-03302 ignition transformer through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Allanson model designed for Gordon Piatt burners.

How to install the Allanson 3G-OTH-03302 ignition transformer?

Ensure the transformer is mounted securely and the 1/4-20 stud HV terminal is connected to the spark electrode. The internal junction box should be wired to a 120V, 60Hz supply. Maintain a loading air gap of 1/16 to 1/8 inches between the electrode and ground for optimal spark performance.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 421-661 Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 421-661 Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson 2714-662 Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 2714-662 Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson 1196-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 1196-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson 1092-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 1092-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson 1112-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 1112-S Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 444-661 Ferromagnetic Service Replacement Transformer for Gordon Piatt

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne