We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
AllansonIgnition Transformers

Allanson 2729-411 Ferromagnetic Transformer for Abc

The Allanson 2729-411 is a ferromagnetic ignition transformer from the Small Can Series, designed for ABC burners. It operates on a 220V, 50Hz input with a secondary voltage of 10,000 volts and a current of 23mA…

SKU 3G-OTH-03130

Also listed as: 2729411 · 2729 411

Brand
Allanson
Item
2729-411 Ferromagnetic Transformer for Abc
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Current
23mA
Can Size
Small Can Series
Grounding
Mid Point Ground
Burner Type
ABC
Hv Terminal
Zinc Plated Button
Input Voltage
220V
Hinge Location
End Hinge
Input Frequency
50Hz
Secondary Voltage
10000 Volt
Burner Manufacturer
ABC

Datasheet Content

[{"filename":"FerromagneticDP_SpecSheet_21-4141121.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 2721 / 2744 / 2730 / 2714 / 421 / 444 / 911 / 912\n SPECIFICATION GUIDE\n\n\n DOUBLE POLE, MID POINT GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial oil applications.\n\n\n Absolute Maximum Ratings\n Model # 2721, 421* 2744, 444* 911* 2730, 912* 2714\n Rated Operating Input Voltage (V) 120 240 240 120 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132 108-132\n Input Supply Frequency (Hz) 60 60 50 50 60\n Primary Voltage - Amperes (VA) 250 250 250 250 275\n Secondary Voltage (RMS) 10,000 10,000 10,000 10,000 12,000\n Secondary Short Circuit Current (mA) 23 23 23 23 20\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90 90\n Loading Air Gap (inches) 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16\n\n * Service replacement transformers are available in select models.\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 99 Adams Blvd., Farmingdale, New York 11735 #21-414\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Allanson 2729-411 is a ferromagnetic ignition transformer from the Small Can Series, designed for ABC burners. It operates on a 220V, 50Hz input with a secondary voltage of 10,000 volts and a current of 23mA, featuring a mid-point ground, zinc-plated button HV terminal, and end hinge configuration.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 2729-411 ferromagnetic transformer used for?

The Allanson 2729-411 is a ferromagnetic ignition transformer designed for constant-duty commercial and industrial oil burner applications. It provides a reliable 10,000 V secondary voltage at 23 mA for ABC burners, ensuring consistent ignition in heating systems.

What are the specifications of the Allanson 2729-411 transformer?

The Allanson 2729-411 operates at 220 V input, 50 Hz, with a secondary voltage of 10,000 V and 23 mA short-circuit current. It features a small can size, mid-point grounding, zinc-plated button HV terminal, and end hinge. Storage temperature range is -40 to +80 °C.

Where to buy the Allanson 2729-411 in Singapore?

You can source the Allanson 2729-411 ferromagnetic transformer through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this ignition transformer for ABC burners.

How to install the Allanson 2729-411 transformer?

Install the Allanson 2729-411 by mounting it securely with the end hinge, connecting the 220 V input to the primary terminals, and attaching the HV output to the burner ignition system. Ensure the mid-point ground is properly connected. Follow Allanson's guidelines for loading air gap of 1/8 to 3/16 inches.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 2729-409 Ferromagnetic Transformer for Abc
Allanson
Allanson 2729-409 Ferromagnetic Transformer for Abc
Allanson 2729-631A Ferromagnetic Transformer for Abc
Allanson
Allanson 2729-631A Ferromagnetic Transformer for Abc
Allanson 2721-411 Ferromagnetic Ignition Transformer for Abc
Allanson
Allanson 2721-411 Ferromagnetic Ignition Transformer for Abc
Allanson 2730-411 Ferromagnetic Ignition Transformer for Abc
Allanson
Allanson 2730-411 Ferromagnetic Ignition Transformer for Abc
Allanson 2721-631A Ferromagnetic Ignition Transformer for Abc
Allanson
Allanson 2721-631A Ferromagnetic Ignition Transformer for Abc
Allanson 2744-411 Ferromagnetic Ignition Transformer for Abc
Allanson
Allanson 2744-411 Ferromagnetic Ignition Transformer for Abc

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne