We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Allanson 2721-252A Ferromagnetic Ignition Transformer - Ignition Transformers
AllansonIgnition Transformers

Allanson 2721-252A Ferromagnetic Ignition Transformer

Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.

SKU 3G-OTH-03246

Also listed as: 2721252A · 2721 252A

Brand
Allanson
Item
2721-252A Ferromagnetic Ignition Transformer
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Poles
Double
Current
23mA
Can Size
Small Can Series
Grounding
Mid Point Ground
Application
OIL
Hv Terminal
Zinc Plated Button
Input Voltage
120V
Hinge Location
Side Hinge
Input Frequency
60Hz
Secondary Voltage
10000V

Datasheet Content

[{"filename":"FerromagneticDP_SpecSheet_21-4141121_04-Sep-2025.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 2721 / 2744 / 2730 / 2714 / 421 / 444 / 911 / 912\n SPECIFICATION GUIDE\n\n\n DOUBLE POLE, MID POINT GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial oil applications.\n\n\n Absolute Maximum Ratings\n Model # 2721, 421* 2744, 444* 911* 2730, 912* 2714\n Rated Operating Input Voltage (V) 120 240 240 120 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132 108-132\n Input Supply Frequency (Hz) 60 60 50 50 60\n Primary Voltage - Amperes (VA) 250 250 250 250 275\n Secondary Voltage (RMS) 10,000 10,000 10,000 10,000 12,000\n Secondary Short Circuit Current (mA) 23 23 23 23 20\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90 90\n Loading Air Gap (inches) 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16\n\n * Service replacement transformers are available in select models.\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 181 Cooper Ave., Suite 112, Tonawanda, NY 14150 #21-414\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03246 ferromagnetic ignition transformer used for?

The Allanson 3G-OTH-03246 is a double-pole, mid-point ground ferromagnetic ignition transformer designed for constant-duty ignition in commercial, residential, and industrial oil-fired burners. It provides a reliable 10,000 V secondary voltage at 23 mA for consistent spark ignition.

What are the specifications of the Allanson 3G-OTH-03246 ignition transformer?

The Allanson 3G-OTH-03246 operates at 120 V input, 60 Hz, with a secondary voltage of 10,000 V and 23 mA short-circuit current. It has a small can size, zinc-plated button HV terminal, side hinge, and a loading air gap of 1/8 to 3/16 inches. Operating temperature range is -30 to +40 °C.

Where to buy the Allanson 3G-OTH-03246 ignition transformer in Singapore?

3G Electric supplies the Allanson 3G-OTH-03246 ferromagnetic ignition transformer to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this model.

How to install the Allanson 3G-OTH-03246 ignition transformer?

Install the Allanson 3G-OTH-03246 by mounting it securely with the side hinge, connecting the 120 V primary supply, and attaching the zinc-plated button HV terminal to the oil burner spark gap. Ensure the loading air gap is set between 1/8 and 3/16 inches for proper ignition. Follow local electrical codes.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 2721-362A Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-362A Ferromagnetic Ignition Transformer
Allanson 2721-068 Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-068 Ferromagnetic Ignition Transformer
Allanson 2721-680 Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-680 Ferromagnetic Ignition Transformer
Allanson 2721-576 Ferromagnetic Ignition Transformer
Allanson
Allanson 2721-576 Ferromagnetic Ignition Transformer
Allanson 2730-252A Ferromagnetic Ignition Transformer
Allanson
Allanson 2730-252A Ferromagnetic Ignition Transformer
Allanson 2744-252A Ferromagnetic Ignition Transformer
Allanson
Allanson 2744-252A Ferromagnetic Ignition Transformer

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne