Allanson 2714-656 Ferromagnetic Ignition Transformer for Beckett
Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.
SKU 3G-OTH-03242
Also listed as: 2714656 · 2714 656
Local availability & support — the Philippines
- Delivery
- 5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
- Payment
- Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
- Ships to
- Manila, Quezon City, Cebu, Davao, Batangas
Need installation or engineering help?
Ask a question
Product Description
Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the Allanson 2714-656 ferromagnetic ignition transformer used for?
The Allanson 2714-656 is a double-pole, mid-point ground ferromagnetic ignition transformer designed for constant-duty ignition in commercial, residential, and industrial oil burners, specifically Beckett models. It provides a reliable 12,000 V secondary voltage at 20 mA for consistent oil flame ignition.
What are the specifications of the Allanson 2714-656 ignition transformer?
The Allanson 2714-656 operates at 120 V input, 60 Hz, with a secondary voltage of 12,000 V RMS and 20 mA short-circuit current. It has a 275 VA rating, a loading air gap of 1/8 to 3/16 inches, and an operating temperature range of -30 to +40 °C. It uses a Rajah connector for the HV terminal.
Where to buy the Allanson 2714-656 ignition transformer in Singapore?
3G Electric supplies the Allanson 2714-656 ferromagnetic ignition transformer to customers in Singapore. We source and deliver this component for Beckett oil burners, handling logistics, customs clearance, and local delivery. Contact us for pricing and lead time on your order.
How to install the Allanson 2714-656 ignition transformer on a Beckett burner?
To install the Allanson 2714-656, first disconnect power and verify the input voltage matches 120 V at 60 Hz. Mount the transformer securely, connect the Rajah HV terminal to the burner's ignition electrode, and ensure the mid-point ground is properly bonded. Follow the burner manufacturer's wiring diagram for safe operation.
Used in
Common applications for AllansonAllanson Products
3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.