Allanson 1112-PF Ferromagnetic Ignition Transformer for Power Flame
Allanson’s Single Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial gas applications.
SKU 3G-OTH-03229
Also listed as: 1112PF · 1112 PF
Local availability & support — the Philippines
- Delivery
- 5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
- Payment
- Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
- Ships to
- Manila, Quezon City, Cebu, Davao, Batangas
Need installation or engineering help?
Ask a question
Product Description
Allanson’s Single Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial gas applications.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the Allanson 3G-OTH-03229 ferromagnetic ignition transformer used for?
The Allanson 3G-OTH-03229 is a single-pole ferromagnetic ignition transformer designed for constant-duty ignition in commercial, residential, and industrial gas-fired burners, specifically for Power Flame burner applications. It provides a reliable 6000V secondary voltage at 20mA to ignite gas in boilers, furnaces, and process heaters.
What are the specifications of the Allanson 3G-OTH-03229 ignition transformer?
The Allanson 3G-OTH-03229 operates at 240V input, 60Hz, with a secondary voltage of 6000V RMS and 20mA secondary short-circuit current. It has a single-pole, one-end-ground design with a thumb-screw HV terminal. Storage temperature range is -40 to +80 °C, and operating temperature is -30 to +40 °C.
Where to buy the Allanson 3G-OTH-03229 in Singapore?
3G Electric supplies the Allanson 3G-OTH-03229 ferromagnetic ignition transformer to customers in Singapore. We source and deliver this component for Power Flame burners, handling logistics, customs clearance, and local delivery. Contact us for pricing and lead time on your order.
How to install the Allanson 3G-OTH-03229 ignition transformer?
Ensure the transformer is mounted securely with proper grounding per the one-end-ground design. Connect the 240V input to the primary terminals and the 6000V secondary to the spark electrode using the thumb-screw HV terminal. Maintain a 1/16 to 1/8 inch air gap for reliable ignition. Always follow the burner manufacturer's wiring diagram.