We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR X G 2.22 LXTL S - Burners & Combustion
FBRBurners & Combustion

FBR X G 2.22 LXTL S

FBR X G 2.22 LXTL S is a two-stage light-oil diesel burner delivering 47.4–94.9 kW thermal power with low NOx emissions below 120 mg/Nm³. Suited for industrial heating and combustion systems requiring efficient…

SKU 3G-FBR-00108

Brand
FBR
Item
X G 2.22 LXTL S
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
120
fan motor w
0.74
power kw max
94.9
power kw min
47.4
flow kg h max
8
flow kg h min
4
ip protection
IP 40
noisiness dba
77
electrical supply
1
power supply info
3~400V, 1N~230V 50Hz
current absorption a
2
thermal power mcal h
147/204-450
nominal electric power w
1.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SK070063_A_en SERIES) LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SERIES) G 2.22R-LX - G 2.22-LX Light-oil burners at two steps pressure - Low NOx (NOx < 120 mg/kWh). They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micrometric adjustment, high flame stability and low emissions. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 2.22R-LX - G 2.22-LX G 2.22R-LX - G 2.22-LX LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SK070063_A_en SERIES) TECHNICAL DATA G 2.22R-LX - G 2.22-LX MODEL G 2.22R-LX G 2.22-LX Flow min. - max. * [kg/h] 4-8 Thermal power min. - max. * [Mcal/h] 40.8-81.6 Thermal power min. - max. * [kW] 47.3-94.7 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 NOx [mg/kWh] < 120:class 3 (EN267) Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 250 140 Fan motor [W] 100 100 Nominal current absorption [A] 1.1 0.7 Pre-heater [W] 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 59-61 Burner weight *** [kg] 10 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with iron cover (F) add 2 kg to the weight. OPERATING RANGE DIAGRAM G 2.22R-LX - G 2.22-LX Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 2.22R-LX - G 2.22-LX LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SK070063_A_en SERIES) DIMENSIONS [MM] Fig. 3 Dimensions G 2.22R-LX - G 2.22-LX MODEL A B C D E F G 2.22R-LX - G 2.22-LX 157 170 275 90 265 210 * See "flame tube length" BOILER PLATE (*) Suggested dimension of connection between burner and generator. F00012 Fig. 4 Boiler plate MODEL [mm] L min L* L max M N min N* N max G 2.22 - LX 130 150 170 M8 100 110 130 G 2.22R - LX 130 150 170 M8 100 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G 2.22R-LX - G 2.22-LX mm 120 160 ** For different flame lengths, please contact our Technical-Sales Department. G 2.22R-LX - G 2.22-LX LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SK070063_A_en SERIES) PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners at two steps pressure - Low NOx (NOx < 120 mg/kWh). DETAILED SPECIFICATION Light-oil burners at two steps pressure - Low NOx (NOx < 120 mg/kWh), composed by: • Aluminium frame; • Combustion head with micrometric adjustment, high flame stability and low emissions; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 2.22R-LX - G 2.22-LX
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G 2.22 LXTL S is a two-stage light-oil diesel burner delivering 47.4–94.9 kW thermal power with low NOx emissions below 120 mg/Nm³. Suited for industrial heating and combustion systems requiring efficient, regulated fuel burning.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I source the FBR X G 2.22 LXTL S burner in the Philippines?

3G Electric Philippines is an authorized distributor of FBR burners including the X G 2.22 LXTL S model. We deliver to Manila, Quezon City, and CALABARZON regions. 3G Electric handles all Bureau of Customs documentation and logistics — lead time on request.

What is the lead time for the FBR X G 2.22 LXTL S diesel burner?

Lead time depends on current stock and sourcing availability. Contact 3G Electric with your delivery address and required date. We manage all import procedures and provide PHP invoicing for Philippines-based buyers.

What are the thermal output and NOx emission specifications of the FBR X G 2.22 LXTL S?

The burner delivers 47.4–94.9 kW thermal power across two combustion stages. NOx emissions are <120 mg/Nm³, meeting low-emission standards for industrial heating and food-processing applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G2.22 R LXTL R S
FBR
X G2.22 R LXTL R S
X G 2.22 LX TC S
FBR
X G 2.22 LX TC S
X G 2.22 R LXTC R S
FBR
X G 2.22 R LXTC R S
FBR
FBR
X G 3.22 LXTL S
X G IS LX S
FBR
X G IS LX S
X G os LXTC S
FBR
X G os LXTC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL