We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR K 190/M TL EL is a dual-fuel diesel burner for industrial heating applications, delivering 349–2395 kW across two modulating stages. Electronic cam control and 481 mm nozzle design support both gas and light-oil…

SKU 3G-FBR-00192

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
stage
2 stages sliding or modulating
fuel type
Dual fuel gas/light oil
nozzle mm
481
power kw max
2395
power kw min
349
electrical supply
3

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073525_A_gb_190-250 OR MODULATING WITH ELECTRONIC CONTROL BOX K 190/M-EL - K 250/M-EL Dual fuel burners gas/light oil with electronic control box. Two stages progressive or modulating operation(ifequipped withadditionof optional modulation kit PID and probe; to guarantee an ideal proportionality of the power supplied to the thermal load). Composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; composed by: working valve class A - safety valve class A - minimum gaspressure switch - gas valve proving pressure switch - filter Supplied with nozzle, fuel selection switch, flange and gasket for installation on boiler, flexible hoses, line filter. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator, one servomotor for the air shutter and one servomotor fo the light-oil modulator. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / fuel ratio) With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet), Touchscreen HMI panel. Fig. 1 K 250/M-EL K 190/M-EL - K 250/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073525_A_gb_190-250 OR MODULATING WITH ELECTRONIC CONTROL BOX TECHNICAL DATA AND OPERATING RANGE DIAGRAM K 190/M-EL - K 250/M-EL MODEL K 190/M-EL K 250/M-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 300/900-2060 400/1000-2500 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 349/1046-2395 465/1163-2907 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 35/105-241 47/117-292 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14/41-93 18/45-113 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)B/I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Minimum pressure gas train D2" FS50 NATURAL GAS/L.P.G. ** [mbar] 152/76 226/110 Minimum pressure gas train DN65 FS65 NATURAL GAS/L.P.G. ** [mbar] 79/47 110/66 Minimum pressure gas train DN80 FS80 NATURAL GAS/L.P.G. ** [mbar] 65/41 90/58 Minimum pressure gas train DN100 FS100 NAT. GAS/L.P.G. ** [mbar] 49/35 69/50 Maximum pressure at the entry of valves (Pe. max) [mbar] 360-500 360-500 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 30/90-206 40/100-250 Fuel: light-oil 1.5°E at 20°C = 6.2 cSt = 35sec Redwood N°1 Nominal electric power [kW] 7 9 Fan motor [kW] 5.5 7.5 Pump motor [kW] 1.1 1.1 Nominal absorption powers [A] 14 16 Nominal absorption auxiliary [A] 0.5 0.7 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP40 IP40 Noisiness *** min. - max. [dB(A)] 81-82 82-86 Burner weight [kg] 140 152 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). [ mbar] 19 15 11 7 3 K 190/M K 250/M -1 300 700 1100 1500 1900 2300 2700 3100 [kW] Fig. 2 X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K 190/M-EL - K 250/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073525_A_gb_190-250 OR MODULATING WITH ELECTRONIC CONTROL BOX DIMENSIONS [MM] 20 A D A R4 B F TL RD G H R1 R2 C R3 Fig. 3 Dimensions MODEL A B C D F G H R1 R2 R3 R4 RD K 190/M-EL - D2" 370 495 966 265 145 647 479 870 777 912 254 Rp 2 K 190/M-EL - DN65 370 495 966 265 145 647 479 688 871 1020 254 DN65 K 190/M-EL - DN80 370 495 966 265 145 647 479 708 811 1005 254 DN80 K 190/M-EL - DN100 370 495 966 265 145 647 479 748 811 991 254 DN100 K 250/M-EL - D2" 370 495 966 265 145 647 479 870 777 912 254 Rp 2 K 250/M-EL - DN65 370 495 966 265 145 647 479 688 871 1020 254 DN65 K 250/M-EL - DN80 370 495 966 265 145 647 479 708 811 1005 254 DN80 K 250/M-EL - DN100 370 495 966 265 145 647 479 748 811 991 254 DN100 BOILER PLATE Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max K 190/M-EL mm 280 280 320 M14 396 424 438 K 250/M-EL mm 280 280 320 M14 396 424 438 * The dimensions of the boiler plate (threaded holes or studs) must be as indicated in the drawing. FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TL ** K 190/M-EL mm 481 K 250/M-EL mm 481 ** For different flame lengths, please contact our Technical-Sales Department. K 190/M-EL - K 250/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073525_A_gb_190-250 OR MODULATING WITH ELECTRONIC CONTROL BOX PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel burners…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR K 190/M TL EL is a dual-fuel diesel burner for industrial heating applications, delivering 349–2395 kW across two modulating stages. Electronic cam control and 481 mm nozzle design support both gas and light-oil combustion for flexible boiler integration.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR K 190/M TL EL burner in the Philippines?

Order from 3G Electric Philippines. We deliver to Manila, Quezon City, and nationwide. 3G Electric handles Bureau of Customs documentation, logistics, and PHP invoicing for seamless procurement.

What is the lead time for the FBR K 190/M TL EL burner?

Lead time on request. Contact 3G Electric Philippines for availability and delivery schedule to your site. We source all components and manage customs clearance to the Philippines.

What is the power range and fuel capability of the FBR K 190/M TL EL?

The FBR K 190/M TL EL delivers 349–2395 kW across two modulating stages. It supports both gas and light-oil combustion with electronic cam control and a 481 mm nozzle for flexible boiler integration in industrial heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K 190/M TL EL (1) | Variant: variant_1 | Subgroup: Burner with electronic cam
FBR
K 190/M TL EL (1) | Variant: variant_1 | Subgroup: Burner with electronic cam
K 350/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
FBR
K 350/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL