We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 )

The GASTEC Detector Tube (MPN 9L) is a nitrogen dioxide (NO2) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures NO2 concentrations from 0.5 to 125 ppm, enabling…

SKU 3G-OTH-553247

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
9L
Type
NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ), 10 PK
Gas Detected
Nitrogen Dioxide
Measurement Range
0.5 to 125 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 9L) is a nitrogen dioxide (NO2) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures NO2 concentrations from 0.5 to 125 ppm, enabling precise field sampling across industrial environments.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC Detector Tube 9L used for?

The GASTEC Detector Tube 9L is used for measuring nitrogen dioxide (NO2) concentrations in industrial environments. It works with GASTEC GV-100 and GV-110 pumps to detect NO2 from 0.5 to 125 ppm, supporting safety monitoring in chemical plants, refineries, and confined spaces.

What are the specifications of the GASTEC Detector Tube 9L?

The GASTEC Detector Tube 9L detects nitrogen dioxide (NO2) with a measurement range of 0.5 to 125 ppm. It is supplied in a 10-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 9L.

Where to buy GASTEC Detector Tube 9L worldwide?

3G Electric supplies the GASTEC Detector Tube 9L worldwide, handling full logistics and customs clearance. As a global industrial solutions provider, we source and deliver genuine GASTEC gas detection tubes to support safety compliance across industries.

How to use the GASTEC Detector Tube 9L with a GV-100 pump?

To use the GASTEC Detector Tube 9L, break both tips of the tube, insert it into the GASTEC GV-100 or GV-110 pump, and pull the handle to draw a sample. Follow the pump stroke count and read the concentration directly from the tube scale. Always refer to the manufacturer's instructions for accurate results.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121SL). Key specifications — Gas Detected: Benzene; Measurement Range: 1 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121SL). Key specifications — Gas Detected: Benzene; Measurement Range: 1 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 2LC). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 4,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 2LC). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 4,000 ppm.
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4HH). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.1 to 4%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4HH). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.1 to 4%.
GASTEC Detector Tube: Gas Detection Tube, LPG, With Pump, 104°F Max Op Temp [NEW], LPG, 10 PK (MPN 100A). Key specifications — Gas Detected: LPG; Measurement Range: 0.02 to 0.8%.
GASTEC
GASTEC Detector Tube: Gas Detection Tube, LPG, With Pump, 104°F Max Op Temp [NEW], LPG, 10 PK (MPN 100A). Key specifications — Gas Detected: LPG; Measurement Range: 0.02 to 0.8%.
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 95°F Max Op Temp [NEW], 10 PK (MPN 91PL). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.01 to 0.8 ppm.
GASTEC
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 95°F Max Op Temp [NEW], 10 PK (MPN 91PL). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.01 to 0.8 ppm.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3LA). Key specifications — Gas Detected: Ammonia; Measurement Range: 2.5 to 200 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3LA). Key specifications — Gas Detected: Ammonia; Measurement Range: 2.5 to 200 ppm.
GASTEC Detector Tube: GASTEC GV-100, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), With Pump, 10 PK (MPN 151L). Key specifications — Gas Detected: Acetone; Measurement Range: 50 to 12,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), With Pump, 10 PK (MPN 151L). Key specifications — Gas Detected: Acetone; Measurement Range: 50 to 12,000 ppm.
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92L). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 1 to 20 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92L). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 1 to 20 ppm.