We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 )

The GASTEC Detector Tube (MPN 3LA) is an ammonia (NH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects ammonia across a measurement range of 2.5 to 200 ppm.

SKU 3G-OTH-553099

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
3LA
Type
NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK
Gas Detected
Ammonia
Measurement Range
2.5 to 200 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 3LA) is an ammonia (NH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects ammonia across a measurement range of 2.5 to 200 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the GASTEC 3LA detector tube used for?

The GASTEC 3LA detector tube is used to measure ammonia (NH3) concentrations in air, typically for industrial hygiene, leak detection, or environmental monitoring. It works with GASTEC GV-100 and GV-110 pumps to provide a reading from 2.5 to 200 ppm.

What are the specifications of the GASTEC 3LA ammonia tube?

The GASTEC 3LA tube detects ammonia (NH3) over a measurement range of 2.5 to 200 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps and is supplied in a 10-pack. The manufacturer part number is 3LA.

Where to buy GASTEC 3LA detector tubes worldwide?

3G Electric supplies GASTEC 3LA ammonia detector tubes worldwide. As a global industrial sourcing partner, we handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 10-pack of tubes for GV-100 pumps.

How to use the GASTEC 3LA ammonia detection tube?

To use the GASTEC 3LA tube, break both tips off using the tip breaker on the GV-100 or GV-110 pump. Insert the tube into the pump inlet with the arrow pointing toward the pump. Pull the handle to draw a full stroke of air, then read the stain length against the scale printed on the tube.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), With Pump, 10 PK (MPN 72). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 0.5 to 120 ppm.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, 5 to 100 ppm, 5 PK (MPN 1LKC). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 5 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121L). Key specifications — Gas Detected: Benzene; Measurement Range: 0.1 to 65 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121L). Key specifications — Gas Detected: Benzene; Measurement Range: 0.1 to 65 ppm.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3H). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.2 to 32% vol.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3H). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.2 to 32% vol.
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1HH). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 1 to 40%.
GASTEC Detector Tube: GASTEC GV-100, C2H3Cl, Gas Detection Tube, Vinyl Chloride ( C2H3Cl ), 10 PK (MPN 131LB). Key specifications — Gas Detected: Vinyl Chloride; Measurement Range: 0.4 to 70 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C2H3Cl, Gas Detection Tube, Vinyl Chloride ( C2H3Cl ), 10 PK (MPN 131LB). Key specifications — Gas Detected: Vinyl Chloride; Measurement Range: 0.4 to 70 ppm.
GASTEC Detector Tube: CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 2D). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 0.02 to 12%.
GASTEC
GASTEC Detector Tube: CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 32°F Min Op Temp [NEW], 10 PK (MPN 2D). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 0.02 to 12%.
GASTEC Detector Tube: GASTEC GV-100, C4H8O, Gas Detection Tube, Methyl Ethyl Ketone ( C4H8O ), 10 PK (MPN 152). Key specifications — Gas Detected: Methyl Ethyl Ketone; Measurement Range: 0.02 to 0.6%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C4H8O, Gas Detection Tube, Methyl Ethyl Ketone ( C4H8O ), 10 PK (MPN 152). Key specifications — Gas Detected: Methyl Ethyl Ketone; Measurement Range: 0.02 to 0.6%.