We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C - High-Temperature Thermocouple Calibrator Furnaces
FLUKEHigh-Temperature Thermocouple Calibrator Furnaces

FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C

The FLUKE Drywell is a high-temperature thermocouple calibrator furnace with a temperature range of 2192°F to 302°F /150°C to 1200°C, designed for Type E, Type J, Type K, and Type T thermocouples. It features a…

SKU 3G-OTH-179296

Brand
FLUKE
Item
Drywell: 2192°F to 302°F /150°C to 1200°C
Category
High-Temperature Thermocouple Calibrator Furnaces
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

FLUKE
Manufacturer Part Number
9150-DW-156
Type
For Type E/Type J/Type K/Type T Thermocouple Type
Stability
+/-0.5°C
For RTD Type
4-Wire
For Stem Diameter
(2) 6 mm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE Drywell is a high-temperature thermocouple calibrator furnace with a temperature range of 2192°F to 302°F /150°C to 1200°C, designed for Type E, Type J, Type K, and Type T thermocouples. It features a stability of +/-0.5°C, supports 4-wire RTD types, and accommodates stem diameters of (2) 6 mm. This unit is identified by manufacturer part number 9150-DW-156.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE Drywell 9150-DW-156 used for?

The FLUKE Drywell 9150-DW-156 is a high-temperature thermocouple calibrator furnace used to calibrate Type E, Type J, Type K, and Type T thermocouples in industrial process control and quality assurance labs. It provides a stable temperature reference from 150°C to 1200°C for verifying sensor accuracy.

What are the specifications of the FLUKE Drywell 9150-DW-156?

The FLUKE Drywell 9150-DW-156 has a temperature range of 150°C to 1200°C, stability of +/-0.5°C, supports 4-wire RTD types, and accommodates two 6 mm stem diameters. It is designed for Type E, Type J, Type K, and Type T thermocouples. The manufacturer part number is 9150-DW-156.

Where to buy the FLUKE Drywell 9150-DW-156 worldwide?

You can source the FLUKE Drywell 9150-DW-156 worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time. 3G Electric supplies this FLUKE calibrator furnace to customers internationally.

How to maintain the FLUKE Drywell 9150-DW-156?

To maintain the FLUKE Drywell 9150-DW-156, keep the well clean and free of debris, and periodically verify its calibration against a reference standard. Avoid thermal shock by allowing the unit to cool before cleaning. Refer to the FLUKE manual for detailed maintenance intervals and procedures.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE high-temperature thermocouple calibrator furnaces. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-E-156). Key specifications — For Stem Diameter: (2) 6 mm; Brand: FLUKE; Stability: +/-0.02°C at 200°C.
FLUKE
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-E-156). Key specifications — For Stem Diameter: (2) 6 mm; Brand: FLUKE; Stability: +/-0.02°C at 200°C.
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-D-156). Key specifications — For Stem Diameter: (2) 4 mm; Brand: FLUKE; Stability: +/-0.03°C at 350°C.
FLUKE
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-D-156). Key specifications — For Stem Diameter: (2) 4 mm; Brand: FLUKE; Stability: +/-0.03°C at 350°C.
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-F-156). Key specifications — For Stem Diameter: (2) 4 mm; Brand: FLUKE; Stability: +/-0.02°C at 200°C.
FLUKE
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-F-156). Key specifications — For Stem Diameter: (2) 4 mm; Brand: FLUKE; Stability: +/-0.02°C at 200°C.
FLUKE Drywell: -196°C to 1,480°C, -196°C to 660°C, +/-0.2°C (Display - Full Range), Adj Set Point (MPN 9142-A-156). Key specifications — For Stem Diameter: 1/4 in; Brand: FLUKE; Stability: +/-0.01°C.
FLUKE
FLUKE Drywell: -196°C to 1,480°C, -196°C to 660°C, +/-0.2°C (Display - Full Range), Adj Set Point (MPN 9142-A-156). Key specifications — For Stem Diameter: 1/4 in; Brand: FLUKE; Stability: +/-0.01°C.
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-DW-156). Key specifications — For Stem Diameter: (2) 3 mm; Brand: FLUKE; Stability: +/-0.02°C at 33°C.
FLUKE
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point (MPN 9143-DW-156). Key specifications — For Stem Diameter: (2) 3 mm; Brand: FLUKE; Stability: +/-0.02°C at 33°C.
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point (MPN 9144-A-156). Key specifications — For Stem Diameter: 3/8 in; Brand: FLUKE; Stability: +/-0.04°C at 420°C.
FLUKE
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point (MPN 9144-A-156). Key specifications — For Stem Diameter: 3/8 in; Brand: FLUKE; Stability: +/-0.04°C at 420°C.

More from FLUKE

View all FLUKE parts
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-A-156). Key specifications — For RTD Type: 4-Wire; Brand: FLUKE; For Stem Diameter: 1/4 in; Stability: +/-0.5°C.
FLUKE
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-A-156). Key specifications — For RTD Type: 4-Wire; Brand: FLUKE; For Stem Diameter: 1/4 in; Stability: +/-0.5°C.
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-C-156). Key specifications — For RTD Type: 3-Wire; Brand: FLUKE; For Stem Diameter: (6) 1/4 in; Stability: +/-0.5°C.
FLUKE
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-C-156). Key specifications — For RTD Type: 3-Wire; Brand: FLUKE; For Stem Diameter: (6) 1/4 in; Stability: +/-0.5°C.
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-B-156). Key specifications — For RTD Type: 4-Wire; Brand: FLUKE; For Stem Diameter: (2) 3/16 in; Stability: +/-0.5°C.
FLUKE
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-B-156). Key specifications — For RTD Type: 4-Wire; Brand: FLUKE; For Stem Diameter: (2) 3/16 in; Stability: +/-0.5°C.
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-D-156). Key specifications — For RTD Type: 2-Wire; Brand: FLUKE; For Stem Diameter: (2) 6 mm; Stability: +/-0.5°C.
FLUKE
FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C, For Type E/Type J/Type K/Type T Thermocouple Type (MPN 9150-D-156). Key specifications — For RTD Type: 2-Wire; Brand: FLUKE; For Stem Diameter: (2) 6 mm; Stability: +/-0.5°C.