FLUKE Drywell: 2192°F to 302°F /150°C to 1200°C
The FLUKE Drywell (MPN 9150-C-156) is a high-temperature thermocouple calibrator furnace with a temperature range of 2192°F to 302°F /150°C to 1200°C. It supports Type E, J, K, and T thermocouples and 3-wire RTDs…
SKU 3G-OTH-179297
Need installation or engineering help?
Ask a question
Product Description
The FLUKE Drywell (MPN 9150-C-156) is a high-temperature thermocouple calibrator furnace with a temperature range of 2192°F to 302°F /150°C to 1200°C. It supports Type E, J, K, and T thermocouples and 3-wire RTDs, with a stability of +/-0.5°C. The unit accommodates up to six probes with a stem diameter of 1/4 in.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the FLUKE Drywell 9150-C-156 used for?
The FLUKE Drywell 9150-C-156 is a high-temperature thermocouple calibrator furnace used to calibrate Type E, J, K, and T thermocouples and 3-wire RTDs in industrial process control, power generation, and laboratory settings. It provides a stable temperature reference from 150°C to 1200°C for verifying sensor accuracy.
What are the specifications of the FLUKE Drywell 9150-C-156?
The FLUKE Drywell 9150-C-156 has a temperature range of 150°C to 1200°C (2192°F to 302°F), stability of +/-0.5°C, and accommodates up to six probes with a stem diameter of 1/4 in. It supports Type E, J, K, and T thermocouples and 3-wire RTDs. The unit is manufactured by FLUKE.
Where to buy the FLUKE Drywell 9150-C-156 worldwide?
You can source the FLUKE Drywell 9150-C-156 worldwide through 3G Electric, a global industrial equipment distributor established in 1990. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we supply this calibrator furnace to customers across multiple industries.
How to select the right FLUKE Drywell for thermocouple calibration?
To select the right FLUKE Drywell, match its temperature range to your application—the 9150-C-156 covers 150°C to 1200°C. Ensure it supports your thermocouple types (E, J, K, T) and RTD configuration (3-wire). Verify probe stem diameter compatibility (1/4 in) and required stability (+/-0.5°C). Consult FLUKE documentation for specific calibration needs.
Used in
Common applications for FLUKEFLUKE Products
3G Electric supplies FLUKE high-temperature thermocouple calibrator furnaces. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.