FLUKE Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C
The FLUKE Drywall Temperature Calibrator (MPN 9140-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 95°F to 662°F / 35°C to 350°C. It offers stability of +/-0.03°C at 50°C…
SKU 3G-OTH-178561
Need installation or engineering help?
Ask a question
Product Description
The FLUKE Drywall Temperature Calibrator (MPN 9140-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 95°F to 662°F / 35°C to 350°C. It offers stability of +/-0.03°C at 50°C and accommodates stem diameters of (2) 6 mm. This FLUKE instrument provides a stable temperature source for field calibration of temperature sensors.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the FLUKE Drywall Temperature Calibrator used for?
The FLUKE Drywall Temperature Calibrator (MPN 9140-D-156) is a single-block drywell calibrator used for field calibration of temperature sensors. It provides a stable temperature source from 35°C to 350°C, making it ideal for verifying thermocouples, RTDs, and other probes in industrial maintenance and HVAC applications.
What are the specifications of the FLUKE 9140-D-156?
The FLUKE 9140-D-156 drywell calibrator covers a range of 35°C to 350°C (95°F to 662°F) with stability of +/-0.03°C at 50°C. It accommodates two stem diameters of 6 mm each. This FLUKE instrument is a single-block design with adjustable setpoints for precise temperature simulation.
Where to buy the FLUKE Drywall Temperature Calibrator worldwide?
3G Electric supplies the FLUKE Drywall Temperature Calibrator (9140-D-156) worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this FLUKE calibrator.
How to maintain the FLUKE Drywall Temperature Calibrator?
To maintain the FLUKE 9140-D-156, keep the drywell clean and free of debris. Use only clean, dry inserts for stem diameters of 6 mm. Periodically verify stability at 50°C against a reference standard. Store the calibrator in a dry, dust-free environment when not in use to ensure long-term accuracy.
Used in
Common applications for FLUKEFLUKE Products
3G Electric supplies FLUKE single-block drywell calibrators with adjustable setpoints. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.