FLUKE Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C
The FLUKE Drywall Temperature Calibrator (MPN 9140-B-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 95°F to 662°F / 35°C to 350°C. It offers a stability of +/-0.05°C at 350°C…
SKU 3G-OTH-178557
Need installation or engineering help?
Ask a question
Product Description
The FLUKE Drywall Temperature Calibrator (MPN 9140-B-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 95°F to 662°F / 35°C to 350°C. It offers a stability of +/-0.05°C at 350°C and accommodates stem diameters of (2) 3/16 in.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the FLUKE Drywall Temperature Calibrator used for?
The FLUKE Drywall Temperature Calibrator (MPN 9140-B-156) is a single-block drywell calibrator used to verify and adjust temperature sensors in industrial process control, HVAC, and quality assurance applications. It provides a stable reference temperature from 95°F to 662°F / 35°C to 350°C.
What are the specifications of the FLUKE 9140-B-156?
The FLUKE 9140-B-156 drywell calibrator covers 95°F to 662°F / 35°C to 350°C with stability of +/-0.05°C at 350°C. It accommodates two stem diameters of 3/16 in. This single-block unit features adjustable setpoints for precise calibration of temperature probes.
Where to buy the FLUKE Drywall Temperature Calibrator worldwide?
3G Electric supplies the FLUKE Drywall Temperature Calibrator (9140-B-156) to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this precision calibration instrument.
How to maintain the FLUKE drywell calibrator for accuracy?
To maintain accuracy, keep the FLUKE drywell calibrator clean and dry, and periodically verify its stability using a reference thermometer. Allow sufficient warm-up time before use. Follow the manufacturer's recommended recalibration interval to ensure +/-0.05°C stability at 350°C is preserved.
Used in
Common applications for FLUKEFLUKE Products
3G Electric supplies FLUKE single-block drywell calibrators with adjustable setpoints. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.