We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye External Servo Interface for NX6100 and PPC6000 - Communication Devices
FireyeCommunication Devices

Fireye External Servo Interface for NX6100 and PPC6000

The 3G-OTH-02769 from Fireye is a communication device designed as an external servo interface for the NX6100 and PPC6000 control systems. It uses CANbus technology to facilitate communication between the control…

SKU 3G-OTH-02769

Also listed as: NXESI 120 · NXESI-120

Brand
Fireye
Item
External Servo Interface for NX6100 and PPC6000
Category
Communication Devices
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
NXESI120, NX6100, PPC6000, NX20, NX50, NX98
Category
Communication Devices
Approvals
CE, cULus
CANbus Communication
The NXESI120 interface leverages CANbus technology to facilitate communication between the control system and the servo motor. This ensures reliable data transfer and control, enhancing the overall performance of your automation system.
Reliable Performance
Built with high-quality components and advanced circuitry, the NXESI120 ensures reliable performance and durability. It maintains consistent communication and power delivery to your servo motors, contributing to the overall stability and efficiency of your automation system.
Simplified Integration
The NXESI120 interface is designed for ease of installation and integration, making it straightforward to connect and configure your servo motors within the NEXUS control system. This user-friendly design reduces setup time and simplifies system management.
Flexible Power Connections
The interface supports connections to line supply levels, typically 120V or 230V AC, and also provides 5V DC connections to the feedback potentiometer. This flexibility allows you to accommodate various power requirements and motor configurations.
Versatile Motor Integration
The NXESI120 interface allows you to connect non-CANbus servo motors to your NEXUS control system, providing compatibility with a range of motors including NX20, NX50, NX98, and other third-party devices. This versatility ensures that you can easily integrate various motors into your existing control infrastructure.
Enhanced System Compatibility
By bridging the gap between non-CANbus servo motors and the NEXUS control system, the NXESI120 expands your system’s compatibility and functionality. This integration capability allows for a more customized and efficient automation setup.
Improved Automation Flexibility
By enabling the connection of a wide range of non-CANbus servo motors, the NXESI120 enhances the flexibility of your automation system, allowing you to tailor your setup to meet specific operational needs and performance requirements.
Dual Connections for Seamless Operation
Equipped with connections to both the CANbus and the servo motor, the NXESI120 ensures efficient power management and communication. The CANbus connection powers and communicates with the on-board microprocessor and associated CANbus circuitry, while the servo motor connections handle line supply levels and feedback.

Datasheet Content

[{"filename":"NXESI-6101-External_Servo_Interface_NXESI120_English_2015-06-15.pdf","text":"NXESI-6101\n June 19, 2015\n\n\n\n\n 3G-OTH-02769\n External Servo Interface\n For NX6100 and\n PPC6000 Series\n\nDESCRIPTION\n\n\n The 3G-OTH-02769 interface provides the facility to connect non-CANbus servo motors, for example\n NX20, NX50, NX98 or third party devices, into a NEXUS control system. The 3G-OTH-02769 has\n connections to the CANbus and to the servo motor. The CANbus powers and communicates\n with the on-board microprocessor and associated CANbus circuitry. Connections to the motor\n are at Line supply levels (typically 120 or 230Vac) and 5Vdc levels to the feedback\n potentiometer.\n\n CAN modules used in the NEXUS family, have unique serial numbers programmed during\n manufacture. These serial numbers are used to define the device type and its function as part of\n the combustion control system, during commissioning. CAN servo motors and the 3G-OTH-02769\n are considered to be ‘Drives’.\n\n Note: If a drive serial number is changed after commissioning, then any profiles using that drive\n will require re-commissioning. A ‘profile invalid’ fault (see FAULT 64) will lock the burner out on\n an attempt to fire a profile which has had a previously commissioned drive removed or changed.\n The profile can be re-commissioned by using the NEXT / ENTER ‘keys’ in commission ratio\n mode to verify all points on the combustion curve.\n\fSafety information\n\n\n WARNING\n The equipment described in this manual is capable of causing property damage, severe injury, or\n death. It is the responsibility of the owner or user to ensure that the equipment described herein is\n installed, operated and commissioned in compliance with the requirements of all national and local\n legislation, which may prevail.\n\n\n\nWhen this equipment is fitted to an appliance due regard must also be given to the requirements of that\nappliance.\n\nBefore attempting to install, commission or operate this equipment all relevant sections of this\ndocument must be read and fully understood. If in doubt about any requirements consult Fireye.\n\nInstallation, commissioning or adjustment of this product MUST be carried out by suitably trained\nengineers or personnel qualified by training and experience.\n\nAfter installation or modifications to the installation all functions of the equipment MUST be checked\nto ensure safe and reliable operation of the control.\n\nThe manufacturer of this equipment accepts no liability for any consequences resulting from inappropriate,\nnegligent or incorrect installation, commissioning or adjustment of operating parameters of the equipment.\nControl panels must not be left uncovered while power is on. If it is essential to do so while rectifying faults\nonly personnel qualified by training and experience should be involved.\n\nThe time any covers are off must be kept to a minimum and warning notices must be posted.\n\nBefore attempting any work on this equipment or any equipment controlled by or connected to this equipment,\nall related electrical supplies must be isolated.\n\nSafety interlocks must not be removed or over-ridden. Any faults once detected must be corrected before\nthe control is operated.\n\n\nCAUTION – SOME VERSIONS OF THIS EQUIPMENT CONTAIN A LITHIUM BATTERY\n IN THE DISPLAY UNIT\n\n\n NOTE\n\nThe manufacturer of this equipment has a policy of continual product improvement and reserves the right to\nchange the specification of the equipment and the contents of this manual without notice.\n\n\n\n\n 2\n\fTable of contents\nThis manual describes the configuration of the 3G-OTH-02769 External Servo Motor Interface.\n\nPlease read the safety information at the front of this manual before proceeding.\n\n\n\n1. Installation 4\n 1.1 Overview. 4\n\n\n2. Installation 5\n 2.1 Mechanical Fixing 5\n 2.2 Option Link selection 5\n 2.3 Wiring Information 6\n\n\n3. Servo motor selection and calibration. 10\n 3.1 Servo-motor selection 10\n 3.2 Locking the servo-motor to the valve shaft 11\n 3.3 Control direction 11\n 3.4 Feedback potentiometer 11\n 3.5 Adjusting micro-switch positions when using Fireye line voltage servomotors. 12\n\n\n4. Technical Specification. 13\n 4.1 General 13\n\n\n\n\n 3\n\f1. Installation\n1.1 Overview.\nThe 3G-OTH-02769 interface provides the facility to connect non-CANbus servo motors, for example NX20,\nNX50, NX98 or third party devices, into a NEXUS control system. The 3G-OTH-02769 has connections to the\nCANbus and to the servo motor. The CANbus powers and communicates with the on-board\nmicroprocessor and associated CANbus circuitry. Connections to the motor are at Line supply levels\n(typically 120 or 230Vac) and 5Vdc levels to the feedback potentiometer.\n\nCAN modules used in the NEXUS family, have unique serial numbers programmed during manufacture.\nThese serial numbers are used to define the device type and its function as part of the combustion control\nsystem, during commissioning. CAN servo motors and the 3G-OTH-02769 are considered to be ‘Drives’.\n\nNote: If a drive serial number is changed after commissioning, then any profiles using that drive will\nrequire re-commissioning. A ‘profile invalid’ fault (see FAULT 64) will lock the burner out on an attempt to\nfire a profile which has had a previously commissioned drive removed or changed. The profile can be re-\ncommissioned by using the NEXT / ENTER ‘keys’ in commission ratio mode to verify all points on the\ncombustion curve.\n\n\n\n\n 4\n\f 2. Installation\n 2.1 Mechanical Fixing\n The 3G-OTH-02769 interface has an IP65 enclosure with 3 cable entry points. Suitable IP65 conduit\n connections should be used to ensure continuity of the IP rating as required.\n\n Mechanical fixing is using the 4 points outside of the IP65 area as shown below:\n\n\n\n 160 mm (6.3”)\n\n\n\n\n Mounting holes\n63 mm63\n (2.48”) 4 x 4.5mm dia.\n 100 mm (3.93”)\n\n\n\n\n 145 mm (5.71”)\n\n\n\n\n 2.2 Option Link selection\n There are two option links that must be set according to the potentiometer configuration within the servo\n motor, as follows.\n\n\n\n Direct (1:1) potentiometer drive, or Geared (3:1) potentiometer drive.\n\n\n\n\n 5\n\f DIRECT DIRECT GEARED GEARED\n DRIVE DRIVE DRIVE DRIVE\n\n\n\n\n JP3 JP3\n JP3 JP2\n JP2 JP3 JP2\n JP2\n\n\n\n\n2.3 Wiring Information\n\n2.3.0 General\n\n\n CAUTION\n  Disconnect the power supply before beginning installation to prevent electrical shock, equipment\n and/or control damage. More than one power supply disconnect may be involved.\n  Wiring must comply with all applicable codes, ordinances and regulations.\n  Loads connected to the 3G-OTH-02769 unit must not exceed those listed in the specifications as given in\n this manual.\n\n\n\n\nThe enclosure MUST be earthed to ensure safe and reliable operation.\n\nThe screen terminals on the 3G-OTH-02769 only perform an ground function and do not provide strain relief,\nthe signal cable screens only connect at the screen terminals, unless stated otherwise.\nSecure all cables carried in conduit at both ends using a suitable anchorage method in the cabinet.\n\n\nWIRING INSTALLATION MUST BE CARRIED OUT BY A COMPETENT ELECTRICIAN AND IS\nSUBJECT TO I.E.E. WIRING REGULATIONS (BS 7671:1992) AND/OR LOCAL STANDARDS WHICH\nMAY PREVAIL.\n\nHAZARDOUS VOLTAGES MUST BE ISOLATED BEFORE SERVICE WORK IS CARRIED OUT.\n\nAll cabling requiring to operate at above 50v must be multi-strand single core PVC insulated 16/0.2mm\nand should meet the requirements of I.E.C. 227 or I.E.C. 225.\n\nDo not use a green/yellow conductor for any purpose other than earth.\n\nTo comply with EMC requirements, wire the 3G-OTH-02769 expansion unit using the specified cable sizes\nand screen connections. Clamp all signal cable screens to earth using the screen terminals provided on\nthe 3G-OTH-02769. Connect all CANBus cable screens to earth at the control end using the screen\ntermination clamps only.\n\n\n\n\n 6\n\f The equipment described in this manual has been tested for compliance to the directives listed in the\nsection headed ‘approvals’ in the NEXUS manual NEX-6101. However, once connected to a burner and\nother associated controls it is the responsibility of the installer to ensure the complete installation meets\n the requirements of the directives relevant to the particular installation.\n\n\n\n\n2.3.1 Terminal layout.\n\nConnection terminals are identified in the picture below.\n\n\n J5\n\n\n\n\n J4\n\n\n\n\n J3 J1\n\n\n2.3.2 Grounding CANBus cable screens.\n\nSeveral screen termination clamps are provided on the main control. The cable should be prepared by\ncutting around the outer sleeve, taking care not to damage the screen\n\n\n\n\n  (1)\n (1). Cut the outer insulation to expose the\n screen.\n\n (2). Pull the sleeving apart to expose 10mm of\n the screen,\n (2) (3). Slide the exposed…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The 3G-OTH-02769 from Fireye is a communication device designed as an external servo interface for the NX6100 and PPC6000 control systems. It uses CANbus technology to facilitate communication between the control system and servo motors, ensuring reliable data transfer. The interface supports flexible power connections to line supply levels (120V or 230V AC) and provides 5V DC connections for the feedback potentiometer. It holds CE and cULus approvals.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye 3G-OTH-02769 used for?

The Fireye 3G-OTH-02769 is an external servo interface that integrates non-CANbus servo motors, such as the NX20, NX50, NX98, or third-party devices, into a NEXUS control system. It facilitates communication and power management between the servo motor and the NEXUS network, enhancing automation flexibility.

What are the specifications of the Fireye 3G-OTH-02769?

The Fireye 3G-OTH-02769 is a communication device with CE and cULus approvals. It connects to the CANbus for data transfer and to servo motors at line supply levels (typically 120 or 230 Vac) and 5 Vdc for the feedback potentiometer. It is compatible with NX6100 and PPC6000 series controllers.

Where to buy the Fireye 3G-OTH-02769 in Singapore?

You can source the Fireye 3G-OTH-02769 through 3G Electric in Singapore. We provide logistics, customs clearance, and delivery services to your facility. Contact us for pricing and lead time on this external servo interface for NEXUS control systems.

How to install the Fireye 3G-OTH-02769?

Installation of the Fireye 3G-OTH-02769 must be performed by suitably trained engineers. Connect the interface to the CANbus and the servo motor, ensuring line supply levels (typically 120 or 230 Vac) and 5 Vdc for the feedback potentiometer are correct. After installation, verify all functions for safe operation.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye communication devices. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
Fireye
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000
Fireye
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000
NXD410TS Touchscreen Interface. The NXD410TS provides the means to setup, monitor and display information from the NXF4000 and PPC4000 series of controls as well as any connected accessories. It provides a full touchscreen interface for monitoring, configuration and commissioning. The NXD410TS touchscreen is panel mounted and connects to the NXF4000 or PPC4000 control using a serial communication cable
Fireye
NXD410TS Touchscreen Interface. The NXD410TS provides the means to setup, monitor and display information from the NXF4000 and PPC4000 series of controls as well as any connected accessories. It provides a full touchscreen interface for monitoring, configuration and commissioning. The NXD410TS touchscreen is panel mounted and connects to the NXF4000 or PPC4000 control using a serial communication cable
NXC Series Servos. 24-30 Vac, supplied from control unit
Fireye
NXC Series Servos. 24-30 Vac, supplied from control unit
Nexus NXEXP300 Water Level Control. The NXEXP300 expands the capability of the parallel positioning system by adding valuable safety-rated digital inputs, sequence draft control, boiler water level control and total dissolved solids (TDS) surface and bottom blowdown control. The small (5” L x 8.5” W x 3.75H) footprint, adjustable voltage (120/230, 50/60 hz.) and simplified wiring provide easy retrofit to existing Fireye systems
Fireye
Nexus NXEXP300 Water Level Control. The NXEXP300 expands the capability of the parallel positioning system by adding valuable safety-rated digital inputs, sequence draft control, boiler water level control and total dissolved solids (TDS) surface and bottom blowdown control. The small (5” L x 8.5” W x 3.75H) footprint, adjustable voltage (120/230, 50/60 hz.) and simplified wiring provide easy retrofit to existing Fireye systems
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications
Fireye
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications

More from Fireye

View all Fireye parts
NXDBVSD VSD Interface Daughter Board. The NXDBVSD VSD Interface Daughter Board is an advanced solution designed to enhance the functionality of your control systems. Equipped with two VSD channels, one analog output, two counter inputs, two programmable relays, and an isolated RS485 Modbus RTU interface, this daughter board is ideal for various industrial applications
Fireye
NXDBVSD VSD Interface Daughter Board. The NXDBVSD VSD Interface Daughter Board is an advanced solution designed to enhance the functionality of your control systems. Equipped with two VSD channels, one analog output, two counter inputs, two programmable relays, and an isolated RS485 Modbus RTU interface, this daughter board is ideal for various industrial applications
NXDBMB Modbus RTU Interface Card. The NXDBMB Modbus RTU interface card is an essential component designed specifically for the PPC6000 and NX6100 systems. This powerful interface card enables seamless networking of up to 15 Fireye Nexus systems, making it a crucial addition for those looking to enhance their industrial automation capabilities
Fireye
NXDBMB Modbus RTU Interface Card. The NXDBMB Modbus RTU interface card is an essential component designed specifically for the PPC6000 and NX6100 systems. This powerful interface card enables seamless networking of up to 15 Fireye Nexus systems, making it a crucial addition for those looking to enhance their industrial automation capabilities