We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye BurnerPRO Flame Safeguard - Flame Safeguard Controls
FireyeFlame Safeguard Controls

Fireye BurnerPRO Flame Safeguard

3G-OTH-02782 controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many 3G-OTH-02782 models are functionally compatible with select Siemens LFL control models and can use…

SKU 3G-OTH-02782

Brand
Fireye
Item
BurnerPRO Flame Safeguard
Category
Flame Safeguard Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Category
Flame Safeguard Controls
Approvals
CE, cULus

Datasheet Content

[{"filename":"MF-00-2-0200-0-048-A__BurnerPRO_Flame_Safeguard.pdf","text":"3G-OTH-02782\nFlame Safeguard Control\n\nBP110 & BP230\nThe Fireye 3G-OTH-02782 is a compact\nmicroprocessor based primary flame\nsafeguard control for single burner\ncommercial heating and process\nequipment applications.\n\nThe 3G-OTH-02782 is a compact microprocessor based\nprimary flame safeguard control for single burner\napplications. The control is designed to provide\nthe proper burner sequencing, ignition and continuous\nflame monitoring for commercial heating and process\nequipment firing oil and gas fuels.\n\nBurnerPRO is for use in non-permanent operations\nthat requires burner recycle at least once every\n24 hours. The 3G-OTH-02782 is applicable for on/off,\nmultistage, or modulating burners used in steam or\nhot water generating small to medium sized boilers.\nThe seven smart LEDs provide operating status and\nlockout information in the event of a safety shutdown.\n\nA complete 3G-OTH-02782 system includes the\nBP110/230 chassis equipped with the type of flame Features & Benefits\namplifier required for the application, appropriate\nflame detector, wiring base and optional alphanumeric • Low cost FSG control.\ndisplay. The 3G-OTH-02782 comes in either (110VAC)\n • Easy to install, easy to operate.\nor 230VAC (50/60Hz) models for greater flexibility in\nyour application. • 110VAC and 230VAC options.\n • Preprogrammed operational timings necessary for\n the safe operation of the burner system.\n 60-2981-1 • Programmable operational timings option via\n 3G-OTH-02782 Wizard software.\n Wiring Base\n Open base with terminal block • Flame rod and UV scanners compatiable.\n and knockouts w/ • Modbus and/or valve proving options.\n grounding finger, 4.2”L x\n • 7 smart LED indicate the status, flame quality and\n 4.2”W x 1.22”H\n reason for lockout.\n • Typical applications: Process Burners, Pilot Burners,\n BP500 Duct Burners, Industrial Gas Burners, Refinery\n Test Unit for 3G-OTH-02782 Applications, Low NOx Burners, Waste Gas Units\n Simple convenient means and Incinerators.\n for field testing the Fireye\n 3G-OTH-02782 controls. • Fireye 3G-OTH-02782 flame safeguard controls are\n used for commercial heating and process equipment\n firing oil and gas fuels.\n\nfireye.com\n\f 3G-OTH-02782\n Flame Safeguard Control\n Specifications\n BP110UV 110 VAC (+20%, -15%) 50/60Hz\n Supply Voltage:\n BP230UV 230 VAC (+10%, -15%) 50/60Hz\n Power Consumption: 7 VA\n Operating -40°C to +60°C (-40°F to 140°F)\n Temperature Rating:\n Storage -50°C to +85°C (-58°F to 185°F)\n Relative Humidity: 90% R.H. (Non-Condensing)\n Multiple LED indication for fan, open/close damper, auto, ignition, flame, alarm and\n Status Indication:\n fault codes.\n Protection Category: IP40 (except wiring base)\n 4.0” (102mm) L x 4.0” (102mm) W x 4.4” (112mm) H (without base)\n Dimensions:\n 4.15” (105mm) L x 4.15” (105mm) W x 5.0” (127mm) H (with base)\n Weight: 2.5 lbs (1.13kg)\n\n\n Flame Detection\n\n\n\n\n UV90L-1 UV5-1 UV1AL-3 or 6 Flame Rod\n\n\n Compatibility Chart\n Part Number Compatibility Zero Purge Modbus VP Part Number Compatibility Zero Purge Modbus VP\n BP230UVFR-S1 LFL1.322 with links no no BP110UVFR-S1 LFL1.322-110v with links no no\n LFL1.333\n BP230UVFR-S2 TMG 740-1/2/3 with links no no BP110UVFR-S2 LFL1.333-110v with links no no\n model 32-32\n LFL1.335\n BP230UVFR-S3 TMG 740-1/2/3 with links no no BP110UVFR-S3 LFL1.335-110v with links no no\n model 45-54\n BP230UVFR-S4 LFL1.635 with links no no BP110UVFR-S4 LFL1.635-110v with links no no\nBP230UVFR-S1M LFL1.322 with links read only no BP110UVFR-S1M LFL1.322-110v with links read only no\n\nBP230UVFR-S2M LFL1.333 with links read only no BP110UVFR-S2M LFL1.333-110v with links read only no\n\nBP230UVFR-S3M LFL1.335 with links read only no BP110UVFR-S3M LFL1.335-110v with links read only no\n\nBP230UVFR-S4M LFL1.635 with links read only no BP110UVFR-S4M LFL1.635-110v with links read only no\n via modbus via modbus\nBP230UVFR-SxM LFL1.xxx read / write no BP110UVFR-SxM LFL1.xxx-110v read / write no\n or links or links\nBP230UVFR-SxMP LFL1.xxx via modbus read / write yes BP110UVFR-SxMP LFL1.xxx-110v via modbus read / write yes\n\n For more information, please contact your local Fireye Distributor.\n fireye.com\n MF-00-2-0200-0-048-A (2024/07)\n ©2024 Fireye. All Rights Reserved.\n All trademarks and service marks referred herein are property\n of their respective owners.\n Join us on"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-02782 controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many 3G-OTH-02782 models are functionally compatible with select Siemens LFL control models and can use the existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. Please refer to the product overview document for compatibility listings.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye 3G-OTH-02782 flame safeguard control used for?

The Fireye 3G-OTH-02782 is a microprocessor-based primary flame safeguard control for single-burner commercial heating and process equipment firing oil and gas fuels. It provides burner sequencing, ignition, and continuous flame monitoring for on/off, multistage, or modulating burners in small to medium boilers, duct burners, and incinerators.

What are the specifications of the Fireye 3G-OTH-02782?

The 3G-OTH-02782 is available in 110 VAC (+20%, -15%) or 230 VAC (+10%, -15%) models at 50/60 Hz, with 7 VA power consumption. It operates from -40°C to +60°C and stores from -50°C to +85°C. Approvals include CE and cULus. It supports flame rod and UV scanners and offers Modbus and valve proving options.

Where to buy Fireye 3G-OTH-02782 in Singapore?

3G Electric supplies the Fireye 3G-OTH-02782 flame safeguard control to customers in Singapore. We handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this model. We source and deliver genuine Fireye controls for commercial and industrial burner applications.

Is the Fireye 3G-OTH-02782 compatible with Siemens LFL controls?

Yes, many Fireye 3G-OTH-02782 models are functionally compatible with select Siemens LFL controls and can use the existing wiring base with no external wiring changes. The 3G-OTH-02782 is also compatible with Satronic TMG controls with minor wiring modifications. Always refer to the Fireye product overview for specific compatibility listings.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye flame safeguard controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Siemens
Siemens
Base LFS 1
Base LOK 16/LFL
Siemens
Base LOK 16/LFL
Siemens
Siemens
Flange for QRB1 (A)
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
Fireye
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems

More from Fireye

View all Fireye parts
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
Fireye
BurnerLogix YZ300 Annunciator. The YZ300 Module shall interface with the Fireye YB110 or ZB110 BurnerLogix and expand on the YB110 or ZB110 annunciation capabilities
M4RT1 Flame Safeguard Control. Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels
Fireye
M4RT1 Flame Safeguard Control. Designed to provide automatic ignition and continuous flame monitoring, the M4RT1/M4RT24 is meant for commercial-sized heating and process burners that use gaseous fuels
BurnerLogix Z Flame Safeguard. The BurnerLogix Z (ZB110) System expands on the standard BurnerLogix Y System by combining boiler control functions with the same burner management control found in the Y system
Fireye
BurnerLogix Z Flame Safeguard. The BurnerLogix Z (ZB110) System expands on the standard BurnerLogix Y System by combining boiler control functions with the same burner management control found in the Y system
MicroM Series MEC120 Flame Safeguard. The MicroM is designed to be backward compatible with existing TFM, UVM and M-Series II controls. The MicroM MEC120 and MEC230 chassis with the appropriate MEP100, MEP200 and MEP500 series programmers provide operations similar to its predecessors and are usually directly interchangeable
Fireye
MicroM Series MEC120 Flame Safeguard. The MicroM is designed to be backward compatible with existing TFM, UVM and M-Series II controls. The MicroM MEC120 and MEC230 chassis with the appropriate MEP100, MEP200 and MEP500 series programmers provide operations similar to its predecessors and are usually directly interchangeable
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
Fireye
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
Fireye
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
Fireye
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown