We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye Test Unit for BurnerPRO - Training Units & Testing Units
FireyeTraining Units & Testing Units

Fireye Test Unit for BurnerPRO

The Fireye Test Unit 3G-OTH-02844 offers a straightforward and convenient method for field testing Fireye BurnerPRO controls. When a Fireye control chassis is connected to the tester, you can simulate and verify a…

SKU 3G-OTH-02844

Also listed as: BP 500 · BP-500

Brand
Fireye
Item
Test Unit for BurnerPRO
Category
Training Units & Testing Units
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
BP500
Category
Training Units & Testing Units

Datasheet Content

[{"filename":"BPT-1000-BP500_Test_Unit_for_BurnerPRO_English_2020-02-10.pdf","text":"BPT-1000\n February 10, 2020\n\n\n\n\n 3G-OTH-02844\n TEST UNIT for\n BurnerPROTM Controls\n\n\n\nDESCRIPTION\nFireye Test Unit type 3G-OTH-02844 provides a simple convenient means for field testing the Fireye BurnerPRO controls.\nWhen a Fireye control chassis is plugged into the tester, a complete burner firing operation can be simulated and\nchecked through the use of switches and indicating lights on the panel. Supports all BurnerPRO models up to third\ngeneration.\n\n\nSPECIFICATIONS\n Supply Voltage: 110VAC/60Hz or 230VAC/50Hz, depending on control type (see table below)\n Power Consumption: 10VA\n Ambient Temperature Limit: 140°F (60°C)\n Fuse: Glass type, 5 x 20 mm, 1A (x2), 250 volts, example Bussman AGC-1 or equivalent\n Shipping Weight: 5 lbs.\n\nOPERATION CHART —Test Unit 3G-OTH-02844\n LINE INPUT FLAME SCANNER FLAME SIGNAL\n CONTROL TYPE\n VOLTAGE SEL. SW SW\n BP110UV UV\n BP110UVFR UV or FR\n 110 VAC AUTO\n BP110UVFRM UV or FR\n BP110UVFRP UV or FR\n BP110UVFR\n AUTO\n BP110UVFRM 110 VAC PbS\n BP110UVFRP\n BP230UV UV\n BP230UVFR UV or FR\n 230 VAC AUTO\n BP230UVFRM UV or FR\n BP230UVFRP UV or FR\n BP230UVFR\n BP230UVFRM 230 VAC PbS AUTO\n BP230UVFRP\nUV control model supports UV & FR flame signal operations. Tester can be set to output both flame signals if AUX\nSwitch is set for AUTO.\n\n\n\n 1\n\fINSTALLATION\n 1. For best results, the 3G-OTH-02844 Test Unit should be placed on a smooth flat surface.\n 2. The 3G-OTH-02844 chassis is grounded via the ground connection supplied by the line power cord.\n 3. Always disconnect the power before inserting the BurnerPRO control into the wiring base.\n Do not touch the wiring base terminals without verifying that the line power has been\n disconnected.\n\nOPERATION AND TESTS\n Identification\n 1. POWER Switch - Simulates the main disconnect switch. Connected between the hot line and\n terminal 1 of the wiring base.\n 2. CALL FOR HEAT Switch - Simulates recycle limit or operating control, connected between\n terminals 4 and 5.\n 3. AIRFLOW Switch - Simulates burner airflow switch. Form C switch connected between\n terminals 4 (C), 13 (NC), and 14 (NO). The switch has a center \"Always ON\" position.\n 4. PROOF OF CLOSURE Switch - Simulates proof of closure switch on main fuel valve. Connected\n between terminals 4 and 12. The switch has a center \"Always ON\" position.\n 5. ACTUATOR Switch - Simulates modulating actuator position for Closed, Low Fire, and High Fire.\n Actuator energizes terminal 8 when at position. The switch has a center \"Always ON\" position.\n 6. FLAME SIGNAL Switch – “ON” it supports for internal simulator, “OFF” it supports for external\n scanner. Permits the flame simulator circuits to be controlled manually or automatically. The\n switch has a center \"Always ON\" position.\n 7. FLAME SENSOR Switch - Selects type of simulating signal for use with appropriate BurnerPRO\n under test. PbS = Infrared, UV = Ultra-Violet, FR = Flame Rod.\n 8. RESET Switch - Momentary switch used for resetting a BurnerPRO unit in a Lockout/Alarm state.\n 9. AUXILIARY Switch - Special function switch for flame output. Toggle to the ‘OPEN’ position\n for single flame behavior. Toggle to the ‘AUTO’ position for (UV+FR) dual flame behavior.\n 10. BLOWER Indicator - Indicates that the burner motor circuit has been energized. Powered by\n terminals 6 & 7.\n 11. ECONOMY Indicator - Indicates position of actuator during Standby/Idle state.\n 12. LOW LIMIT Indicator - Indicates position of actuator during low fire or light-off states.\n 13. HIGH LIMIT Indicator - Indicates position of actuator during high fire or Purge states.\n 14. IGINITION Indicator - Indicates that the ignition transformer has been energized. Powered by\n terminal 16.\n 15. PILOT Indicator - Indicates that the pilot valve has been energized. Powered by terminal 17.\n 16. MAIN DIRECT Indicator - Indicates that the Main Direct fuel valve has been energized. Powered\n by terminal 18.\n 17. MAIN PILOTED Indicator - Indicates that the Main Piloted fuel valve has been energized.\n Powered by terminal 19.\n 18. RELEASE TO MODULATE Indicator - Indicates that the system has established main flame and\n has transitioned control to the \"external\" load controller.\n 19. FLAME Indicator - Indicates that flame signal is present.\n 20. POWER Indicator - Indicates that mains power is available.\n 21. ALARM Indicator - Indicates that the BurnerPRO control is in Lockout state.\n 22. OLED/LCD 2x16 Display - Use to show the burner sequence states.\n\n\n\n2\n\fOPERATING PROCEDURE FOR AUTOMATIC UNITS\n 1. Turn “Power” switch off.\n 2. Install a BurnerPRO control and secure it in the tester with the mounting screws.\n 3. Refer to the description of operation and the programming sequence chart in the Fireye bulletin\n for the control being tested.\n 4. Turn on the “Power” switch and position the control switches accordingly.\n 5. Installation and operating instructions provided in the Fireye BurnerPRO bulletin (BP-1003)\n will assist with testing and troubleshooting.\n 6. Ignition failure test can be simulated by turning the “flame signal switch” off (left position) and\n initiating a normal start up cycle. At the appropriate time the ignition circuits will be energized\n for the duration of the trial for ignition period, and then de-energized. The pilot or main fuel\n valve circuit will not be energized and the control will lockout.\n 7. Main flame failure test can be simulated by turning the “flame signal switch” off, during a\n normal firing period. The main fuel valve circuit will be de-energized and the control will\n lockout.\n 8. For external scanner testing, attach a UV90L, UV1AL, or 48PT2 to the scanner test jacks. Make\n sure the scanner is hooked into the proper port and the polarity of S1/S2 is correct. Set the flame\n signal switch to the OFF position. During Standby conditions, if a flame source (halogen lamp\n or cigarette lighter) is applied close to the scanner sight window, the installed BurnerPRO\n control unit should signal that a flame signal is detected. If the 3G-OTH-02844 is run through its\n operating sequence and the flame source is applied to the scanner during the ignition phase, the\n BurnerPRO control unit would transition through PTFI, MTFI, and AUTO. Removing the\n applied flame source will subsequently lead to a flame loss lockout.\n\nPANEL LAYOUT OPERATING\n CONTROL\n INPUT\n\n\n\n\n REMOTE FLAME SIGNAL S1 & S2\n RESET SELECT SWITCH FOR SCANNER\n PUSH BUTTON SCANNER TYPE\n SELECT SWITCH TESTING\n\n\n\n 3\n\fDIMENSIONS\n\n\n\n\nNOTICE\n When Fireye products are combined with equipment manufactured by others and/or integrated into systems\n designed or manufactured by others, the Fireye warranty, as stated in its General Terms and Conditions of Sale,\n pertains only to the Fireye products and not to any other equipment or to the combined system or its overall\n performance.\n\nWARRANTIES\n FIREYE guarantees for one year from the date of installation or 18 months from date of manufacture of its prod-\n ucts to replace, or, at its option, to repair any product or part thereof (except lamps and photocells) which is\n found defective in material or workmanship or which otherwise fails to conform to the description of the product\n on the face of its sales order. THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES AND\n FIREYE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY,\n EXPRESS OR IMPLIED. Except as specifically stated in these general terms and conditions of sale, remedies\n with respect to any product or part number manufactured or sold by Fireye shall be limited exclusively to the\n right to replacement or repair as above provided. In no event shall Fireye be liable for consequential or special\n damages of any nature that may arise in connection with such product or part.\n\n\n\n\n FIREYE, Inc. BPT-1000\n 3 Manchester Road February 10, 2020\n Derry, New Hampshire 03038 USA Supersedes MAY 4, 2016\n Fireye.com\n\n\n\n4"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye Test Unit 3G-OTH-02844 offers a straightforward and convenient method for field testing Fireye BurnerPRO controls. When a Fireye control chassis is connected to the tester, you can simulate and verify a complete burner firing operation using the panel’s switches and indicator lights. This versatile unit supports all BurnerPRO models up to the third generation.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye 3G-OTH-02844 Test Unit used for?

The Fireye 3G-OTH-02844 Test Unit is used for field testing Fireye BurnerPRO controls. It simulates and verifies a complete burner firing operation using panel switches and indicator lights, supporting all BurnerPRO models up to the third generation.

What are the specifications of the Fireye 3G-OTH-02844 Test Unit?

The Fireye 3G-OTH-02844 Test Unit operates on 110 VAC/60 Hz or 230 VAC/50 Hz supply voltage, consumes 10 VA, and has an ambient temperature limit of 140°F (60°C). It includes two glass fuses (5 x 20 mm, 1A, 250 volts) and weighs 5 lbs.

Where to buy the Fireye 3G-OTH-02844 Test Unit in Singapore?

You can source the Fireye 3G-OTH-02844 Test Unit through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this Fireye testing equipment.

How to install the Fireye 3G-OTH-02844 Test Unit?

Place the Fireye 3G-OTH-02844 Test Unit on a smooth flat surface. Ground the chassis via the line power cord. Always disconnect power before inserting the BurnerPRO control into the wiring base, and avoid touching terminals without verifying power is disconnected.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye training units & testing units. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
Fireye
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
Fireye
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
SCN-TST-02-03 Flame Scanner Tester. Reliable Flame Detection Testing — Anywhere, Anytime The Scanner Tester is a professional‑grade solution for testing Fireye flame detectors and integrated flame scanners without the need for a live burner. By accurately simulating both infrared (IR) and ultraviolet (UV) radiation found in real burner flames, it enables safe, precise verification during commissioning, maintenance, and troubleshooting. Designed for both field and workshop use, the Scanner Tester combines portability, robust construction, and advanced diagnostic capabilities in a single, easy‑to‑use device. Key Capabilities Realistic Flame Simulation The Scanner Tester reproduces authentic bu
Fireye
SCN-TST-02-03 Flame Scanner Tester. Reliable Flame Detection Testing — Anywhere, Anytime The Scanner Tester is a professional‑grade solution for testing Fireye flame detectors and integrated flame scanners without the need for a live burner. By accurately simulating both infrared (IR) and ultraviolet (UV) radiation found in real burner flames, it enables safe, precise verification during commissioning, maintenance, and troubleshooting. Designed for both field and workshop use, the Scanner Tester combines portability, robust construction, and advanced diagnostic capabilities in a single, easy‑to‑use device. Key Capabilities Realistic Flame Simulation The Scanner Tester reproduces authentic bu
BurnerPRO Flame Safeguard. BurnerPRO controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many BurnerPRO models are functionally compatible with select Siemens LFL control models and can use the existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. Please refer to the product overview document for compatibility listings
Fireye
BurnerPRO Flame Safeguard. BurnerPRO controls are the ideal solution for both new installations and retrofit of Siemens LFL controls. Many BurnerPRO models are functionally compatible with select Siemens LFL control models and can use the existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. Please refer to the product overview document for compatibility listings

More from Fireye

View all Fireye parts
SB Series Training Unit. The Fireye Model 57SB4-1000 Tester provides a convenient means for testing SB Series controllers and sensors. It also is a good tool for learning about the sequences and safety features of all the sbSeries models
Fireye
SB Series Training Unit. The Fireye Model 57SB4-1000 Tester provides a convenient means for testing SB Series controllers and sensors. It also is a good tool for learning about the sequences and safety features of all the sbSeries models
Nexus NX6300 Training Unit. Maximize efficiency and gain mastery over parallel positioning controls with the Nexus NX6300 Training and Demo Unit. The NX-ATU-6300 is designed to help users explore the full potential of the Nexus NX6300 controller, making it ideal for hands-on training and system demonstrations
Fireye
Nexus NX6300 Training Unit. Maximize efficiency and gain mastery over parallel positioning controls with the Nexus NX6300 Training and Demo Unit. The NX-ATU-6300 is designed to help users explore the full potential of the Nexus NX6300 controller, making it ideal for hands-on training and system demonstrations
57AV7 Universal Test Unit. Fireye test unit Type 57AV7 Model 1000 provides a simple and convenient means to field-test the Fireye M-Series, M-Series II and MicroM controls
Fireye
57AV7 Universal Test Unit. Fireye test unit Type 57AV7 Model 1000 provides a simple and convenient means to field-test the Fireye M-Series, M-Series II and MicroM controls
Nexus Training Units. The Nexus training and demo units (NX-ATU-4000 or NX-ATU-6000) provide users with the ability to familiarize themselves with the functions and features of the Nexus NXF4000, PPC4000, NX6100 and PPC6000 controller range
Fireye
Nexus Training Units. The Nexus training and demo units (NX-ATU-4000 or NX-ATU-6000) provide users with the ability to familiarize themselves with the functions and features of the Nexus NXF4000, PPC4000, NX6100 and PPC6000 controller range
57AV4 Test Unit. Fireye Test Unit type 57AV4 provides a simple convenient means for field testing the Fireye Flame-Monitor with components, and “C” and “D” series controls. When a Fireye control chassis is plugged into the tester, a complete burner firing operation can be simulated and checked through the use of switches and indicating lights on the panel
Fireye
57AV4 Test Unit. Fireye Test Unit type 57AV4 provides a simple convenient means for field testing the Fireye Flame-Monitor with components, and “C” and “D” series controls. When a Fireye control chassis is plugged into the tester, a complete burner firing operation can be simulated and checked through the use of switches and indicating lights on the panel