We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR FGP 50/M TC EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 50/M TC EVO SA

FBR FGP 50/M TC EVO SA is a light-oil burner for industrial heating applications, featuring progressive two-stage flame control with thermal output ranging 1416–15000 Mcal/h. The unit delivers 17442 kW maximum power…

SKU 3G-FBR-00067

Brand
FBR
Item
FGP 50/M TC EVO SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
250
fan motor w
55
power kw max
17442
power kw min
1647
flow kg h max
1471
flow kg h min
142
ip protection
IP40
noisiness dba
94-98
pump motor kw
5.5
electrical supply
3
power supply info
3~400V
current absorption a
1.2
thermal power mcal h
1416/5000- 15000
nominal electric power w
61
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_A_en_FGP750-1800 MODULATING LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR MODULATING FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. The adoption of strong metal components makes the burner durable also in heavy duty conditions. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Available with mechanical cam or with electronic cam. Fig. 1 FGP 750/M FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_A_en_FGP750-1800 MODULATING TECHNICAL DATA MODEL FGP 750/M FGP 1000/M FGP 1300/M FGP 1500/M FGP 1800/M Thermal power min.1°st. / min.2°st. - max.2°st. * [Mcal/h] 968/3400-7500 968/3400- 998/3600- 998/3600- 1416/5000- 10000 11500 13000 15000 Thermal power min.1°st. / min.2°st. - max.2°st. * [kW] 1125/3953- 1125/3953- 1160/4186- 1160/4186- 1647/5814- 8721 11628 13372 15116 17442 Light-oil flow min.1°st. / min.2°st. - max.2°st. * [kg/h] 97/333-735 97/333-980 100/353-1127 100/353-1274 142/490-1471 Fuel: Light-oil 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Enviromental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 60 60 Nominal electric power [kW] 27 35 41.5 49.5 61 Fan motor [kW] 22 30 37 45 55 Pump motor [kW] 3 4 4 4 5.5 Fan motor absorption [A] 43 55.5 64.2 77.6 94 Pump motor absorption [A] 6.7 8.6 8.6 8.6 11.7 Power supply 3~400V - 1/N~230V-50Hz Degree of electric protection IP40 Noiseness ** max. [dB(A)] 84-88 86-92 90-93 92-95 94-98 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level) ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_A_en_FGP750-1800 MODULATING BURNER DIMENSIONS [MM] Fig. 3 Burner dimensions MODEL A B C D E F H TL FGP 750/M 600 654 845 448 832 1453 22 685 FGP 1000/M 600 654 845 468 832 1453 22 685 FGP 1300/M 600 654 845 500 832 1453 22 655 FGP 1500/M 600 654 845 500 832 1453 22 655 FGP 1800/M 700 664 880 540 945 1560 22 685 BOILER PLATE The dimensions of the boiler plate (threaded holes or studs) must be as indicated in the drawing. Fig. 4 Boiler plate MODEL M L min L* max P min P max FGP 750/M mm M16 707 778 460 540 FGP 1000/M mm M16 707 778 480 540 FGP 1300/M mm M16 707 778 520 540 FGP 1500/M mm M16 707 778 520 540 FGP 1800/M mm M18 806 890 550 630 * Suggested dimension. FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_A_en_FGP750-1800 MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Light-oil burner two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe; composed by: • Frame made of steel; • Centrifugal fan at high pressurization with reverse curved blades at low noisiness; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Easy extraction of combustion head without get off the burners by bolier; • Flange and insulating gasket for fixing at boiler/furnace; • Control box for control and supervision of burner; • Photoresistance for flame detection; • Three-phase power supply; • Fan motor start-up made by delta/star system FGP 750/M - FGP 1000/M; • Fan motor start-up made by soft-starter system FGP 1300/M - FGP 1500/M - FGP 1800/M; • IP40 electric protection level; • Safety air pressure switch to stop the fuel pump in case of failed or anomalous fan operation, causing the lockout of the burner; • Servomotor for air shutter and for the fuel pressure regulator; • Mobile shutter with total closure when idle for minimize the energetic losses related at boiler cooling; • Light-oil gear pump operated by specific electric motor; • Nozzle assembly with magnet to control inlet/return needle nozzle; • Maximum light-oil pressure switch to stop the burner in case of the light-oil pressure on the return is higher then the set point value; • Set up for the additional specific kit that transforms burner operation as modulating i.e.the modulating kit allows to supply any power between the minimum and maximum value based on instantaneous loading request. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power modulating kits for temperatures; • Power modulating kits for pressures; • Temperature probe 0°C-400°C (PT 100 a 0° C); • Temperature probe 0°C-1200°C (K probe); • Pressure probe 0-3 bar, 0-6 bar. 0-16 bar, 0-20 bar, 0-30 bar; • Noise protection; • Minimum light-oil pressure switch. • The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FGP 750/M - FGP 1000/M - FGP 1300/M - FGP 1500/M - FGP 1800/M
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FGP 50/M TC EVO SA is a light-oil burner for industrial heating applications, featuring progressive two-stage flame control with thermal output ranging 1416–15000 Mcal/h. The unit delivers 17442 kW maximum power and operates on 3~400V electrical supply, fitting mid-range industrial boiler and furnace installations.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR FGP 50/M TC EVO SA burner in the Philippines?

3G Electric Philippines is an authorized distributor. We source the FBR FGP 50/M TC EVO SA and arrange delivery to Manila, Quezon City, and CALABARZON regions. 3G Electric handles Bureau of Customs documentation and logistics end-to-end. Request a quote for lead time and PHP invoice.

What is the lead time and delivery schedule for the FGP 50/M TC EVO SA?

Lead time depends on current availability and destination within the Philippines. Contact 3G Electric with your delivery address for a confirmed schedule. We handle all customs clearance and coordinate logistics to your facility.

Can the FBR FGP 50/M TC EVO SA burner switch between high and low flame?

Yes. The FGP 50/M TC EVO SA features progressive two-stage flame control (hi-low), delivering 1647 kW minimum to 17442 kW maximum. An optional modulation kit with thermal probe enables full PID modulating mode for continuous output adjustment.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 50/M TL EVO SA
FBR
FGP 50/M TL EVO SA
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TC EVO SA
FBR
FGP 100/M TC EVO SA
FGP 50/2 TC EVO 3 SI
FBR
FGP 50/2 TC EVO 3 SI
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FBR
FBR
G 0S LX TC
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FBR
FBR
G X5 F TL
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL