We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

DUNGS MB-VEF 415-425 B01, Gas-air-ratio control - Gas multibloc
DungsGas multibloc

DUNGS MB-VEF 415-425 B01, Gas-air-ratio control

The DUNGS GasMultiBloc® MB-VEF 415-425 integrates filter, gas-air ratio controls, valves and pressure switches in one compact fitting.

SKU 3G-OTH-02925

Also listed as: MBVEF415425B01 · MB VEF 415 425 B01

Brand
Dungs
Item
MB-VEF 415-425 B01, Gas-air-ratio control
Category
Gas multibloc
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Datasheet Content

[{"filename":"mb-vef-415-425-b01_datasheet_en_225658.pdf","text":"GasMultiBloc\n Combined regulation and\n safety valve\n Infinitely variable air/gas\n ratio control mode\n\n MB-VEF 415 - 425 B01\n\n 7.28\n\n\n\n\n Flange, line sockets, pulse lines and screw unions are not contained in the scope of supply\n\n\n Technical description The modular system permits individual solu-\n The DUNGS GasMultiBloc MB-VEF…B01 in- tions using valve proving system, min./max.\n tegrates filter, gas-air ratio controls, valves and pressure switch, pressure limiter.\n pressure switches in one compact fitting:\n Application\n - Dirt trap The gas-air ratio control enables the opti-\n MB-VEF 415/420: pre-mount filter mum mixture formation for forced air burn-\n (microfilter) ers and premix burners; this applies to the\n MB-VEF 425: sieve modulating and two-stage variable operat-\n - Solenoid valves up to 360 mbar (36 kPa) ing modes. Suitable for gases of families 1,\n as per DIN EN 161 Class A Group 2 2, 3 and other neutral gaseous media.\n\n\n\n\n Printed in Germany • Edition 04.19 • Nr. 225 658\n - Sensitive adjustment of gas and air pres-\n sure ratio Approvals\n - Servo pressure regulator as per DIN EU type testing certificate as per:\n EN 88-1 Class A Group 2; EN 12067-1 • EU-Gas Appliances Regulation\n - High flow values at low pressure drop • EU-Pressure Equipment Directive\n - Ratio V = pBr / pL 0.75 : 1 ... 3 : 1 Approvals in other important gas consum-\n - Zero point correction N possible ing countries.\n - External pulse lines, pulse flange\n - Interference degree N possible\n - Flange connections with pipe threads as\n per ISO 7/1\n1…8\n\fFunctional description Block diagram MB-VEF\nGas flow\n1. If the valves V1 and V2 are closed,\n chamber a is under input pressure\n up to the double seat of valve V1.\n2. A hole in the filter housing of\n MB-...415/420 connects min. pres-\n sure switch with chamber a. If the\n input pressure applied to the pres-\n sure switch exceeds the incoming\n reference value, it switches through\n to the automatic burner control.\n3. After release by the automatic burner\n control, valves V1 and V2 open.\n The gas flow through chambers\n a, b and c of the MultiBloc is then\n released.\n V1 Main valve 1 a, b, c Pressure chambers in\n V2 Main valve 2 flow direction\nOperating method of valve-regulator\n V3 Control valve 3 pBr Burner pressure\ncombination on valve V1 V4 Control valve 4 pF Firing chamber pressure\nA regulator compensated for residual pamb Ambient pressure\npressure is integrated in valve V1 (pres- M Working diaphragm pL Blower pressure\n D Throttling point\nsure regulating part).\n 1, 2, 3, 4, 5 G 1/8 screw plug\nAnchor V1 is not connected with the V Ratio setting 9 test nipples\nvalve plate unit. When it opens, the N Zero point correction 6, 7, 8 Pulse lines pL, pF, pBr\nanchor pretensions the pressure spring\nand releases the valve plate unit. Pressure taps, gas train diagram\nWhen the valve closes, the anchor acts\ndirectly on the valve plate unit. MB-VEF 415/420\nValves V1 and V2 are released at the\nsame time.\nIn closed position valve V3 blocks the\npressure chamber under working dia-\nphragm M against input pressure Pe in\nchamber a.\n\nThe pressure under working diaphragm\nM is defined by a variable flow cross-\n 2 3 4\nsection D.The comparison diaphragms MB-VEF 425 p p p\n\nfor burner pressure pBr and blower\npressure pL are interconnected via a\nrod. Moving the bearing point sets the\nratio V.\nZero point correction N acts on this rod.\nThe ambient pressure pamb or the firing\nchamber pressure pF must be applied\nto the opposite side of the comparison\ndiaphragms. Firing chamber pressure\nhas a reducing effect on the burner\npressure at a ratio of V > 1.\nChanges2p resulting 3from\n p\n the\n 4\n p\n force\nequilibrium lead to a modification of\nthe flow cross-section D downstream\nof valve V4. Pressure under the work-\ning diaphragm is re-adjusted and the\nvalve plate unit V1 changes the free\ncross-section.\n\nOperating method of valve V2\nThe anchor of valve V2 is connected Valve V4 is activated by valve V2. In Closing function\nwith the valve plate unit.When it opens, closed position, valve V4 blocks the If the supply voltage to the solenoid\nthe anchor pretensions the pressure chamber under the working diaphragm coils is interrupted, the pressure spring\nspring. M from the burner pressure. closes the main valves within < 1 s.\nValve V2 opens completely and without\ndelay.\n\n 2…8\n\f Specifications\n\n Nominal diameters MB-VEF 415 B01, MB-VEF 420 B01 MB-VEF 425 B01\n Flange with pipe threads as per Rp 1, 1 1/4, 1 1/2, 2\t\t\t Rp 2\n ISO 7/1 (DIN 2999) and their combinations\t\t\n\n Max. operating pressure 360 mbar\n Input pressure ranges MB-…VEF S10/12 pe : 5 mbar to 100 mbar\n MB-…VEF S30/32 pe : 100 mbar to 360 mbar\n Guiding range pL : 0.4 to 100 mbar\n Burner pressure range pBr: 0.5 to 100 mbar\n\n Media Gases of families 1, 2, 3 and other neutral gaseous media\n\n Ambient temperature -15 °C to +70 °C (Do not operate MB-VEF below 0 °C in liquid gas systems. Only\n suitable for gaseous liquid gas, liquid hydrocarbons destroy sealing materials)\n\n Dirt trap unit Suitable gas filter must be installed upstream for safety reasons. Filter housing\n with microfilter, for MB-VEF 415/420. For MB-VEF 425, insert gas filter, e.g. type\n GF 520/1. Datasheet pre-mount filter\n\n Pressure switch Types GW…A5, ÜB…A2 / NB…A2 to DIN EN 1854 may be attached.\n For further information, refer to Datasheets 5.02 and 5.07 “Pressure Switches\n for DUNGS Multiple Actuators”\n\n Servo pressure regulator Pressure regulator compensated for residual pressure, leakproof seal when\n switched off by means of valve V1 as per DIN EN 88-1 Class A and EN 12067-\n 1. Gas-air ratio control with adjustable ratio V as well as zero point correction N\n and firing chamber pressure connection.\n\n Ratio setting range V Ratio V = pBr / pL 0.75 : 1 ... 3 : 1; other ratios on request\n\n Zero point correction N Possible\n\n Solenoid valve V1 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n Solenoid valve V2 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n\n Measuring G 1/8 DIN ISO 228, on inlet and outlet flange, on both sides downstream of\n dirt trap, on both sides between valves (pressure switch mounting can partly\n exclude measuring)\n\n Burner pressure monitor pBr Downstream of valve V2, pressure switch mountable laterally to adapter\n Pressure tap on outlet flange\n\n Pulse and connection lines G 1/8 connection as specified to DIN ISO 228 for burner pressure (pBr; GAS), blower\n pressure (pL; AIR), firing chamber pressure (pF ; combustion, atmosphere)\n Pulse and connection lines must be made of steel to PN1, DN4. Conden-\n sate of pulse and connection lines must not enter into fitting. Strictly\n follow the operating and mounting instructions.\n\n Voltage/frequency MB-VEF 415/420 B01: 50 - 60 Hz, 230 V AC, -15% +10 %\n MB-VEF 425 B01: \t\t 50 - 60 Hz, 230 V AC, -15% +10 %\n\n\n Electrical connection Plug connection as per DIN EN 175301-803 for valves and pressure switches\n\n Rating/power consumption see type overview\n Switch-on duration 100 %\n Protection type/interference…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS GasMultiBloc® MB-VEF 415-425 integrates filter, gas-air ratio controls, valves and pressure switches in one compact fitting.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DUNGS MB-VEF 415-425 B01 used for?

The DUNGS GasMultiBloc MB-VEF 415-425 B01 is a gas-air ratio control for forced air burners and premix burners. It integrates filter, solenoid valves, and pressure switches in one compact fitting, suitable for gases of families 1, 2, 3 and other neutral gaseous media.

What are the specifications of the DUNGS MB-VEF 415-425 B01?

The DUNGS MB-VEF 415-425 B01 features solenoid valves up to 360 mbar (36 kPa) as per DIN EN 161 Class A Group 2, a servo pressure regulator per DIN EN 88-1 Class A Group 2, and a ratio V = pBr / pL of 0.75:1 to 3:1. It includes zero point correction and external pulse lines.

Where to buy the DUNGS MB-VEF 415-425 B01 in Singapore?

3G Electric supplies the DUNGS MB-VEF 415-425 B01 to Singapore. We handle logistics, customs clearance, and delivery to your site. Contact our team for pricing and lead time on this gas multibloc for industrial burner applications.

How to install the DUNGS MB-VEF 415-425 B01?

Install the DUNGS MB-VEF 415-425 B01 in the gas line with flow direction matching the arrow on the body. Use flange connections with pipe threads per ISO 7/1. Note that flange, line sockets, pulse lines, and screw unions are not included. Ensure proper sealing and test for leaks after installation.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DUNGS MBC-300/700/1200-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-300/700/1200-VEF, Infinitely variable air/gas ratio control mode
DUNGS MB-D(LE) 403 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 403 B01, One-stage mode
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve
Dungs
DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve
Valve block MBVEF 412 B01 S30 replaced by MBVEF 412 B01 S32
Dungs
Valve block MBVEF 412 B01 S30 replaced by MBVEF 412 B01 S32
Valve block MBVEF 407 B01 S30 replaced by MBVEF 407 B01 S32
Dungs
Valve block MBVEF 407 B01 S30 replaced by MBVEF 407 B01 S32

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®