We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

DUNGS MB-D(LE) 403 B01, One-stage mode - Gas multibloc
DungsGas multibloc

DUNGS MB-D(LE) 403 B01, One-stage mode

The DUNGS GasMultiBloc® MB-D(LE) 403 integrates filter, regulator, valves and pressure switches in one compact fitting.

SKU 3G-OTH-02920

Also listed as: MBDLE403053B01 · MB DLE 403 053 B01

Brand
Dungs
Item
MB-D
Category
Gas multibloc
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Datasheet Content

[{"filename":"mb-dle-403-053-b01_datasheet_en_214765.pdf","text":"GasMultiBloc\n Combined regulator and\n safety shut-off valves\n Single-stage function\n\n MB-D(LE) 403 B01\n\n 7.20\n\n\n\n\n Technical description The modular system permits individual\n The DUNGS GasMultiBloc® integrates filter, solutions by using external ignition gas tap\n regulator, valves and pressure switches in in connection with separately controlled\n one compact fitting. valves, by adding a valve proving system,\n mini/maxi pressure switches, pressure limit-\n - Dirt trap: microfilter ers, partial volume setting by closing stroke\n - One regulator and two main valves: limiter at valve V2 and regulator blocking for\n B01 liquid gas applications.\n - Two valves are fast opening\n - One valve is fast opening, one valve is Application\n slow opening The modular system permits individual\n - Solenoid valves up to 200 mbar (20 kPa) solutions in gas safety and regulator engi-\n as per DIN EN 161 Class A Group 2 neering. Suitable for gases of families 1, 2,\n - Sensitive setting of output pressure by 3 and other neutral gaseous media.\n\n\n\n\n Printed in Germany • Edition 01.18 • Nr. 214 765\n proportional regulator as per DIN EN 88\n Class A Group 2 Approvals\n - High flow rates with low pressure drop EC type testing certificate as per:\n - DC solenoid drive interference degree N • EC-Gas Appliances Regulation\n - Main volume restrictor at valve V2 Approvals in other important gas consum-\n - Hydraulic opening delay ing countries.\n - Flange connections with pipe threads as\n per ISO 7/1\n - Simple mounting, compact, light-\n weight\n\n1…6\n\fFunctional description of gas flow\n Sectional drawing of MB-DLE...\n1. When the valves V1 and V2 are\n closed, chamber A is under inlet\n 16 17 18 19\n pressure.\n2. A hole D in the filter housing con-\n nects min. pressure switch with\n chamber A. If the inlet pressure\n applied to the pressure switch ex-\n ceeds the incoming reference value,\n it switches through to the automatic\n burner control.\n3. After release by the automatic bur-\n ner control, valves V1 and V2 open.\n The gas flows through chambers A, 10\n B and C of the GasMultiBloc. 9\n 15\n 14\n 8\nOperating method of valve-regulator 7\n 13\ncombination on valve V1 12\n 6\nA regulator, compensating for residual 11\n 5\npressure is integrated in valve V1 (pres-\n 4\nsure regulating part). Armature 7 is not\n V1 V2\nconnected to valve plate unit 3. When 3\n p1 p2\nit opens, armature 7 pretensions com- 2 A B\n\npression spring (V1) 5 and releases 1 C\nthe valve plate unit. When the valve E\n\ncloses, the armature acts directly on\nthe valve plate unit. The output pres-\nsure upstream of valve V2 is defined\nby pretensioning regulating spring 8\n(tension spring) via setting screw 16. 1 Pressure regulator 8 Regulating spring 15 Solenoid housing\nThe output pressure acts via opening E 2 Microfilter 9 Solenoid V1 Setting:\non the working diaphragm of regulator 3 Valve V1 10 Electrical connection 16 - Gas pressure pa\npart 1. In regulated state, setting spring 4 Connection flange 11 Valve V2 17 - Main volume\n 5 Closing spring V1 12 Closing spring V2 18 - Fast stroke\ninlet pressure and pressure of working 6 Housing 13 Armature V2 19 Hydraulic brake\ndiaphragm are in force equilibrium. 7 Armature V1 14 Solenoid V2\n\nOperating method of valve V2\nArmature 13 of valve V2 is connected to Pressure taps\nvalve plate unit 11. When it opens, arma- 2 3\nture 13 pretensions closing spring 12.The pe pa\nmaximum valve opening can be set by\nlimiting the armature stroke by means of 1\n 4\n 1 4\nthe main volume restrictor 17.\nMin. opening (residual stroke) of\nvalve (0.5 to 1.0 mm) 2 3\n pe pa\nMain volume restrictor 17 is set by rotat-\n 1,3,4 G 1/8\n P1 screw plug\ning the adjusting plate or the hydraulic Mp 1 3 2 2 3 1\n 2\t\t TestL1nipple, optional\n N\nbrake 19. The fast and/or slow opening P1\n L1\n Mp\n N\ncharacteristic is influenced by setting\nthe fast stroke 18 at the hydraulic brake Electrical connection\n19 under the cover.\n P1 Mp\n L1 N\nClosing function S 20/S 50\n MP\n N\n\nWhen the supply voltage to the solenoid\ncoils of valves V1 and V2 is interrupted,\n 1\n\n\n\nthey are closed within < 1 s by the 2\n\ncompression springs. P1 Mp P2\n L1 N P1 L2\n L1\nClosing stroke limitation (option) P1 Mp P2\nA partial volume setting is possible by S 22/S 52 MP\n L1 N L2\n\nmeans of a closing stroke limiter. Valve N\n\n\nV2 becomes a regulating actuator 1\n\n\nwithout zero shutoff. Partial volume and P2\n L2\n P1 Mp P2\n L1 N L2\nmain volume are adjustable. 3 2\n\n\n\n P1\n L1\n\n 2…6\n\f Specifications\n\n Nominal diameters MB-…403 B01\n Flange with pipe threads as per Rp 3/8, 1/2\n ISO 7/1 (DIN 2999) and their combinations\n\n Max. operating pressure MB-…403 pmax.= 200…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS GasMultiBloc® MB-D(LE) 403 integrates filter, regulator, valves and pressure switches in one compact fitting.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DUNGS MB-D(LE) 403 B01 gas multibloc used for?

The DUNGS MB-D(LE) 403 B01 is a gas multibloc used for single-stage burner control in industrial gas systems. It integrates a filter, regulator, two safety shut-off valves, and pressure switches into one compact fitting. It is suitable for gases of families 1, 2, 3 and other neutral gaseous media.

What are the specifications of the DUNGS MB-D(LE) 403 B01?

The DUNGS MB-D(LE) 403 B01 features solenoid valves rated up to 200 mbar (20 kPa) per DIN EN 161 Class A Group 2, and a proportional regulator per DIN EN 88 Class A Group 2. It includes a microfilter, fast-opening valves, a main volume restrictor at valve V2, and flange connections with pipe threads per ISO 7/1.

Where to buy the DUNGS MB-D(LE) 403 B01 in Singapore?

3G Electric supplies the DUNGS MB-D(LE) 403 B01 gas multibloc to customers in Singapore. We source and deliver this Dungs component, handling logistics, customs clearance, and local delivery. Contact our team for pricing and lead time on your order.

How to install the DUNGS MB-D(LE) 403 B01 gas multibloc?

Install the DUNGS MB-D(LE) 403 B01 by mounting it with flange connections per ISO 7/1 pipe threads. Ensure the gas supply is off before installation. Connect the inlet to chamber A and outlet to chamber C. Wire the solenoid valves to the burner control per the Dungs datasheet. Test for leaks after installation.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FBR
FBR
GAS P 550/M CE-LX TL EL EVO (1) Cl. 3 | Variant: metano | Subgroup: Burner with electronic cam
GAS P 450/M CE-LX TL EL EVO (1) Cl. 3. | Variant: metano | Subgroup: Burner with electronic cam
FBR
GAS P 450/M CE-LX TL EL EVO (1) Cl. 3. | Variant: metano | Subgroup: Burner with electronic cam
FBR
FBR
GAS P 350/M CE-LX TL EL EVO (1) Cl. 3 | Variant: metano | Subgroup: Burner with electronic cam
GAS P 250/M CE-LX TL MEC Cl. 3 | Variant: metano | Subgroup: Burner with mechanical cam
FBR
GAS P 250/M CE-LX TL MEC Cl. 3 | Variant: metano | Subgroup: Burner with mechanical cam
GAS P 350/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3
FBR
GAS P 350/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3
GAS P 550/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3
FBR
GAS P 550/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®