We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
BrahmaBurner Controls

Brahma FC 7/R cell

Brahma FC 7/R is a flame-sensor photocell control for fuel-oil burners, using light-based detection to monitor combustion. It integrates into burner control systems requiring reliable flame verification and safety…

SKU 3G-CBM-05980

Also listed as: REL 40204 · REL-40204

Brand
Brahma
Item
FC 7/R cell
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Brahma
type
FC 7/R
fuel type
fuel_oil_burners
application
flame_sensor_photocell
detection method
light_based

Datasheet Content

PHOTOCELLS FLAME SENSORS FOR FUEL OIL BURNERS FC7 Introduction Flame detection in fuel oil burners occurs by means of sensors detecting the presence of flame through an electrical FC8 signal, which can be used by ignition and control devices. Generally, to detect the presence of flame in these appliances a photocell is used, which exploits the light generated by the flame itself. Description These are the most used flame sensors for fuel oil burners. Photocells vary their ohmic resistance according to the light FC9 incidence; this property is exploited to detect the occurred flame generation in burners. Various types of photocells are available, differing from each other in their application and casing. Fig.1 shows the FC7, FC8 and FC9 photocells; the difference between FC7 and FC8 models consists in the detecting element, which lights up laterally in the FC7 and frontally in the FC8. The FC9 photocell is suitable to be light up laterally; an inbuilt diode FC11 enables this photocell to be used with particular devices (for example Brahma 32CN ). Fig.2 shows the FC11, FC13 and FC14 photocells, differing from each other only in the fixing system, as both of them light up laterally and frontally. Fig.3 shows FC14 and FC14L photocells, differing from each other in the case length, even if both of them are able to be light up laterally and frontally. They are provided with a connection plug which facilitates assembly and maintenance operations. The standard length of the photocell connecting cable is FC13 600mm; the operating temperature range ensuring the longest life of flame sensors (approximately 50,000 hours) is comprised between 0°C and +60°C. FC14 FC14L Sensitivity The sensitivity of photocells can be identified through the colour of their casing, according to the following directions: /N Black /R Red /A Blue /V Green The colour red indicates photocells with standard sensitivity, the colour blue corresponds to the most sensitive photocells, whereas the colour green marks the least sensitive photocells. For the right coupling between photocell and control device please refer to our technical literature regarding control devices making use of these flame sensors. 4073_r01 1/2 Followings are the sensitivity ranges of the available flame - FC13 ∅17.5 sensors: FC7/R 1,5..5,5 lux Lateral side FC7/A 1,5..3,0 lux ∅8.5 FC7/V 3,0..5,5 lux 43 66.7 FC8/R 1,5..5,5 lux Fig.2 Frontal side FC8/A 1,5..3,0 lux - FC14 FC8/V 3,0..5,5 lux ∅ 17.5 FC9/N 1,5..5,5 lux 43,5 ∅8.5 Lateral side FC9/A 1,5..3,0 lux 61 FC9/V 3,0..5,5 lux - FC14L ∅17.5 Frontal and lateral side FC11/N 1,5..6,5 lux FC11/A 1,5..3,0 lux ∅8.5 100 Frontal and lateral side FC13/R 1,5..6,5 lux 117.5 FC13/A 1,5..3,0 lux Fig.3 Frontal and lateral side FC14/R 1,5..6,5 lux Drilling plane FC11 FC14/A 1,5..3,0 lux ∅8.5 Frontal and lateral side FC14L/R 1,5..6,5 lux FC14L/A 1,5..3,0 lux 17 17 34 FC7, FC8 e FC9 models - FC7 e FC9 FC13 and FC14 drilling plane (fastening system for the 5 4,4 6.9 19 mechanical interference with the photocell case) 2 46 34 ∅17 ∅14.2 17 15.6 24,5 34,7 46 - FC8 Ø4mm screws are recommended to fasten FC7, FC8, FC9 5 4,4 6.9 18,5 and FC11 flame sensors. 46 34 ∅17 Accessories 17 The cable for FC14 and FC14/L photocells is an accessory. 24,5 46.5 The standard cable length is 620mm (cables having different Fig.1 length are available upon request). Drilling plane FC7, FC8 e FC9 ∅17.5 17 17 The photocells can be provided upon request with a protection cap for the detecting element to protect it against 34 damage in case of impact FC11, FC13 e FC14 Models - FC11 5 4,4 29.8 12 ∅8.5 46 29.5 14.75 19 24.2…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Brahma Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Brahma FC 7/R is a flame-sensor photocell control for fuel-oil burners, using light-based detection to monitor combustion. It integrates into burner control systems requiring reliable flame verification and safety shutdown capability.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Brahma FC 7/R flame sensor in the Philippines?

3G Electric Philippines stocks and sources the Brahma FC 7/R photocell. We deliver to Manila, Quezon City, and throughout the Philippines. Our team handles Bureau of Customs documentation and provides PHP invoicing for your procurement.

What is the lead time for the Brahma FC 7/R?

Lead time on request. 3G Electric sources the FC 7/R photocell for prompt delivery to the Philippines. Contact us for availability and logistics scheduling to your location.

How does the FC 7/R photocell detect flame in fuel-oil burners?

The Brahma FC 7/R uses light-based detection to monitor combustion in fuel-oil burner systems. It verifies flame presence and triggers safety shutdown if flame is lost, ensuring reliable burner control and safe operation.

Used in

Common applications for Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Products

3G Electric supplies Brahma burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
UV cell 1
Brahma
UV cell 1
Base NE 18210114
Brahma
Base NE 18210114
Base N 18210095
Brahma
Base N 18210095
Relay GF 2/03
Brahma
Relay GF 2/03
Relay CM 11F
Brahma
Relay CM 11F
Relay CM 11F
Brahma
Relay CM 11F

More from Brahma

View all Brahma parts
Relay MM 192.4 TW5/TS10
Brahma
Relay MM 192.4 TW5/TS10
Relay G 22 S03N TV15/TS10
Brahma
Relay G 22 S03N TV15/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735
Brahma
Brahma
Relay GR1 10.10