We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Honeywell Cell C 7035 A 1023 - Controls
HoneywellControls

Honeywell Cell C 7035 A 1023

Honeywell Cell C 7035 A 1023 is an ultraviolet flame detection cell for burner control systems. It detects ultraviolet radiation and mounts in standard 1 inch tubes, fitting combustion safety applications requiring…

SKU 3G-CBM-04257

Also listed as: HON 22110 · HON-22110

Brand
Honeywell
Item
Cell C 7035 A 1023
Category
Controls
UNSPSC
39121026 — Control power transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Honeywell
type
UV flame detection cell
detection
ultraviolet radiation
mount tube size
1 inch

Datasheet Content

Honeywell Les cellules C7027A, C7035A, C7044A détectent le rayonnement ultraviolet de toutes flammes. Elles sont utilisées avec les équipements de contrôle et de sécurité de flamme pour assurer la surveillance des brûleurs à gaz, à mazout, ou mixtes. La cellule C7027A se monte sur un tube de visée de 1/2" par l'intermédiaire d'un écrou de serrage intégré. L.a cellule C7035A se monte sur un tube de visée de 1" par l'intermédiaire d'un écrou de serrage intégré. Un écran protège le tube de détection. La cellule C7035A répond aux normes d'étanchéité panneau des laboratoires «Underwritters Inc» NEMA 3 et NEMA 4. La cellule C7044A se monte sur un simple support avec deux vis. Le tube de détection se trouve à l'intérieur d'un - tube acier inoxydable. La cellule C7044A peut être utilisée pour des visées inclinées ou verticales. Leur faible encombrement fait que les cellules C7027A et C7044A sont tout parti­ culièrement recommandées pour être montées sur des nez de brûleurs. Installés dans des conditions normales, ces appareils sont prévus pour supporter des pressions jusqu'à 5 psi (35 kPa). Le tube de détection de la cellule C 7035A peut être remplacé sur le site. Les tubes de détection des cellules C7027A et C7044A ne sont pas remplaçables sur le site. Deux Minipeepers peuvent être câblés en parallèle dans le cas de visées difficiles. ® Marque déposée

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell Cell C 7035 A 1023 is an ultraviolet flame detection cell for burner control systems. It detects ultraviolet radiation and mounts in standard 1 inch tubes, fitting combustion safety applications requiring reliable flame monitoring.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Honeywell Cell C 7035 A 1023 in the Philippines?

Order the Honeywell Cell C 7035 A 1023 UV flame detection cell from 3G Electric Philippines. We deliver to Manila, Quezon City, and handle all logistics and Bureau of Customs documentation. Lead time on request.

What is the mounting size for the Cell C 7035 A 1023?

The Honeywell Cell C 7035 A 1023 mounts in standard 1 inch tubes, making it compatible with most burner control combustion chambers and flame detection assemblies.

How does the Honeywell Cell C 7035 A 1023 detect flame?

The Cell C 7035 A 1023 is a UV (ultraviolet) flame detection cell that monitors ultraviolet radiation emitted during combustion, providing reliable burner safety shutdown if flame is lost.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Cell C 7027 A 1056
Honeywell
Cell C 7027 A 1056
Cell C 7061 A 1020
Honeywell
Cell C 7061 A 1020
Cell C 7027 A 1049
Honeywell
Cell C 7027 A 1049
Cell C 7076 A 1031
Honeywell
Cell C 7076 A 1031
Cell C 7044 A 1006
Honeywell
Cell C 7044 A 1006
Cell C 7027 A 1049 with DIN connector
Honeywell
Cell C 7027 A 1049 with DIN connector

More from Honeywell

View all Honeywell parts
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar