We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
ParkerOil Nozzles

Parker Pressure regulator 24-VK1-2.5 5 Bars (replacement 24-VK1-300)

Parker 24-VK1 pressure regulator rated at 5 bar, maximum 40 bar capacity, designed for oil burners with return flow, compressed air, and steam atomizers. Handles fuel temperatures to 140°C, suitable for combustion…

SKU 3G-CBM-03987

Also listed as: FLU 34002 · FLU-34002

Brand
Parker
Item
Pressure regulator 24-VK1-2.5 5 Bars
Category
Oil Nozzles
UNSPSC
23153143 — Spray nozzle
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Parker
application
oil burners with return flow/compressed air/steam atomisers
max pressure
40 bar
regulator type
24-VK1
pressure rating
5 bar
max fuel temperature
140°C

Datasheet Content

REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Documentation The following information sheets illustrate the description below: 24-T201-4G-E Sectional view of the regulator 24-VK1 with main dimensions 24-T201-D0-E Graph of relative output at constant pressure drop 24-T201-DB-E Graph of output at 90° opened 24-T301-4G-E Sectional view of the regulator 24-VK2 with main dimensions General The regulator 24-VK is designed for use in or on oil burners equipped either with return flow atomisers or with compressed air atomisers or steam atomisers. Turning the regulator shaft changes the aperture inside the regulator, consequently changing the fuel flow rate. Both flanges at the regulator shaft are marked with a "+", a scale in 15° steps and a "-". The pointer mounted on one side of the regulator shaft shows the actual position of this shaft. The regulator is suitable for pressures up to 40 bar and fuel temperatures up to 140°C. Mounting The connection block has two 6,5 mm holes and four threaded M5 bores for mounting purposes. These provisions also allow mounting a control motor or an optional heating plate. To prevent malfunction, be careful when removing the plastic plugs from the connection ports and make sure no material stays behind. In case of air atomisation or steam atomisation, the regulator is to be connected in the supply line between the pump and the atomiser. With a return flow atomiser, the regulator is to be connected in the return line from the atomiser. Connections The connections on the block of the regulator are marked as follows: I Fuel inlet to the regulator. O Fuel outlet from the regulator. When choosing fittings, make sure that the channels inside the connection block remain fully open. Even a partial blockage at one of the channels inside will inevitably lead to malfunctioning of the regulator. Never use any additional sealant on the thread. The remains getting inside the regulator could lead to failures. There are no objections against the use of flat gasket rings to seal the fittings. © Fluidics Instruments BV Page 1/2 REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Function Turning the regulator shaft changes the flow through the regulator. The marking of "+" and "-" always refers to the throughput of the regulator and not to the output of the actual atomiser. The throughput of the regulator is at minimum with the pointer at "-". Turning the regulator shaft towards "+" increases the throughput of the regulator. Therefore, in case of air or steam atomisation, the output of an atomiser is at maximum if the pointer is at "+". On the other hand, for a return flow atomiser, the output of the atomiser will be at minimum if the pointer is at "+". The flanges have a scale with 15° division. This scale allows reproducible adjustment of the regulator during operation. The throughput of the regulator always is related to a certain pressure difference between the inlet and the outlet of the regulator. The pressure drop across the regulator and the maximum throughput depend on the actual atomiser and system particulars. In order to benefit from the maximum angle of travel, the choice of the size for the regulator should be made in such a way that its maximum throughput fits the actual atomiser and method of atomisation. Here also system particulars should be taken into account. If firing heavy fuel, we advise mounting a heating device to preheat the regulator for those applications where the fuel flow often stops during longer intervals. It is sufficient to apply an electrical heating plate to preheat the regulator connection block. Two 6,5 mm bores in the connection block allow mounting such a heating plate. This heater could work permanently, but it should at least be switched on in time before fuel is supposed to start flowing to achieve correct operation. Maintenance The regulator normally does not require any maintenance. Wear or damage highly depends on fuel quality. The only moving part is the regulator shaft. After a long period of operation, wear on the sleeve or on the regulator shaft can occur, resulting in an increase of leak flow at minimum throughput. After a while some wear may occur on the o-rings. Complete seal sets are available for replacement. In case of wear of the sleeve or of the regulator shaft, it is advised to return the regulator to the factory for repair. It is not recommended to perform this kind of repairs without proper tools and test equipment. The regulator shaft and the sleeve are being manufactured within close tolerances to avoid operation difficulties after such repairs. To exchange the o-rings in the flange, remove the pointer, held by 1 screw. Remove any damages and polish any sharp edges at both ends of the regulating shaft. Remove both flanges, each held by 2 screws, but leave the regulating shaft in its place. Carefully remove both o-rings from their grooves using a sharp needle without damaging the flanges in any way. Before re-assembly, make sure all parts involved are undamaged and perfectly clean. In case the regulator shaft has come out by accident, put it back in the correct position. Otherwise, the regulator will not function at all afterwards. Put the new o-rings in place. Near the o-rings, the regulator shaft should be absolutely free of damages. Re-assemble the regulator in reverse order. The position of the pointer on the regulator shaft has been pre-set at the factory. Both ends of the regulator shaft have a pit for fixing the pointer in the correct position. If the regulator shaft is mounted properly and the pointer is fixed again using this pit, the characteristic of the regulator will not change after replacement of o-rings. © Fluidics Instruments BV Page 2/2 Regulator 24—VK1 24-T201-4G-E 28-09-10 M5x12/17_ (8x) Pointer O-ring 7,66x1,78 06.5 (2x) O-ring 17,17x1,78 Connection block Sleeve Flange Regulatorshaft © Fluidics Instruments BV Page 1/1
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Parker Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Parker 24-VK1 pressure regulator rated at 5 bar, maximum 40 bar capacity, designed for oil burners with return flow, compressed air, and steam atomizers. Handles fuel temperatures to 140°C, suitable for combustion control and fluid atomization systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Parker 24-VK1 pressure regulator in the Philippines?

3G Electric Philippines supplies the Parker 24-VK1-2.5 5 bar regulator for delivery to Manila and Quezon City. We handle Bureau of Customs documentation, logistics, and PHP invoicing. Request a quote via our website or contact our team for lead times and pricing.

What is the lead time for the Parker 24-VK1 regulator?

Lead time is on request and depends on stock location and import clearance. 3G Electric manages all customs documentation for Philippines delivery. Contact us for a specific timeline for the Parker 24-VK1-2.5 5 bar model (part FLU34002).

Is the Parker 24-VK1 regulator suitable for oil burners with compressed air atomizers?

Yes. The Parker 24-VK1 is rated 5 bar at 40 bar maximum capacity and handles fuel temperatures to 140°C. It is designed for oil burners with return flow, compressed air, and steam atomizers in combustion control and fluid atomization applications.

Used in

Common applications for Parker
Injection molding machine proportional directional control — Parker solenoid coils and proportional valve cartridges for mold-closing and hydraulic actuation circuits
Construction equipment hydraulic steering and boom control — Parker directional control valves with solenoid actuation for excavator and loader hydraulic systems
Industrial press forming systems — Parker pressure-relief and proportional directional valves for tonnage control and cycle sequencing
Material-handling conveyor systems — Parker proportional control valves with solenoid pilot stages for smooth load acceleration and deceleration
Tire-building machinery — Parker solenoid-actuated directional cartridges for synchronized multi-axis hydraulic positioning
Forestry and mobile equipment — Parker valve spools and solenoid assemblies rated for harsh-environment hydraulic circuits and mobile-duty pressure cycling

Parker Products

3G Electric supplies Parker oil nozzles. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Pressure regulator 24-VK1-4.2 5 Bars (replacement 24-VK1-650)
CBM
CBM
Pressure regulator 24-VK1-5.2 5 Bars (replaces 24-VK1-850)
CBM
CBM
Pressure regulator 24-VK1-3.3 5 Bars (replaces 24-VK1-450)
CBM
CBM
Pressure regulator 24-VK1-2.7
This Parker pressure regulator is constructed with a stainless steel body and features 1/4 in FNPT x FNPT connections. It provides an adjustable outlet pressure range of 14.7 psi to 24.7 psi. Suitable for use in pneumatic systems requiring corrosion resistance and stable pressure control
Parker
This Parker pressure regulator is constructed with a stainless steel body and features 1/4 in FNPT x FNPT connections. It provides an adjustable outlet pressure range of 14.7 psi to 24.7 psi. Suitable for use in pneumatic systems requiring corrosion resistance and stable pressure control
This Parker stainless steel pressure regulator features 1/4 in FNPT x FNPT connections and a pressure range of 14.7 psi to 24.7 psi. It is used to reduce and stabilize inlet pressure in pneumatic systems, suitable for industrial applications requiring corrosion resistance
Parker
This Parker stainless steel pressure regulator features 1/4 in FNPT x FNPT connections and a pressure range of 14.7 psi to 24.7 psi. It is used to reduce and stabilize inlet pressure in pneumatic systems, suitable for industrial applications requiring corrosion resistance

More from Parker

View all Parker parts
Fluidics 0.85 45° SF
Parker
Fluidics 0.85 45° SF
Fluidics 0.45 80° HF
Parker
Fluidics 0.45 80° HF
Fluidics 1,10 60° SF
Parker
Fluidics 1,10 60° SF