We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
CBMOil, Fuel & Nozzles

CBM Pressure regulator 24-VK1-2.7

CBM FLU | Régulateur pression 24-VK1-2.7

SKU 3G-CBM-03986

Also listed as: FLU 34001 · FLU-34001

Brand
CBM
Item
Pressure regulator 24-VK1-2.7
Category
Oil, Fuel & Nozzles
UNSPSC
23153143 — Spray nozzle
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

CBM
type
Oil burner pressure regulator
max pressure
40 bar
threaded bores
4x M5
connection holes
2x 6.5mm
max fuel temperature
140°C

Datasheet Content

REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Documentation The following information sheets illustrate the description below: 24-T201-4G-E Sectional view of the regulator 24-VK1 with main dimensions 24-T201-D0-E Graph of relative output at constant pressure drop 24-T201-DB-E Graph of output at 90° opened 24-T301-4G-E Sectional view of the regulator 24-VK2 with main dimensions General The regulator 24-VK is designed for use in or on oil burners equipped either with return flow atomisers or with compressed air atomisers or steam atomisers. Turning the regulator shaft changes the aperture inside the regulator, consequently changing the fuel flow rate. Both flanges at the regulator shaft are marked with a "+", a scale in 15° steps and a "-". The pointer mounted on one side of the regulator shaft shows the actual position of this shaft. The regulator is suitable for pressures up to 40 bar and fuel temperatures up to 140°C. Mounting The connection block has two 6,5 mm holes and four threaded M5 bores for mounting purposes. These provisions also allow mounting a control motor or an optional heating plate. To prevent malfunction, be careful when removing the plastic plugs from the connection ports and make sure no material stays behind. In case of air atomisation or steam atomisation, the regulator is to be connected in the supply line between the pump and the atomiser. With a return flow atomiser, the regulator is to be connected in the return line from the atomiser. Connections The connections on the block of the regulator are marked as follows: I Fuel inlet to the regulator. O Fuel outlet from the regulator. When choosing fittings, make sure that the channels inside the connection block remain fully open. Even a partial blockage at one of the channels inside will inevitably lead to malfunctioning of the regulator. Never use any additional sealant on the thread. The remains getting inside the regulator could lead to failures. There are no objections against the use of flat gasket rings to seal the fittings. © Fluidics Instruments BV Page 1/2 REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Function Turning the regulator shaft changes the flow through the regulator. The marking of "+" and "-" always refers to the throughput of the regulator and not to the output of the actual atomiser. The throughput of the regulator is at minimum with the pointer at "-". Turning the regulator shaft towards "+" increases the throughput of the regulator. Therefore, in case of air or steam atomisation, the output of an atomiser is at maximum if the pointer is at "+". On the other hand, for a return flow atomiser, the output of the atomiser will be at minimum if the pointer is at "+". The flanges have a scale with 15° division. This scale allows reproducible adjustment of the regulator during operation. The throughput of the regulator always is related to a certain pressure difference between the inlet and the outlet of the regulator. The pressure drop across the regulator and the maximum throughput depend on the actual atomiser and system particulars. In order to benefit from the maximum angle of travel, the choice of the size for the regulator should be made in such a way that its maximum throughput fits the actual atomiser and method of atomisation. Here also system particulars should be taken into account. If firing heavy fuel, we advise mounting a heating device to preheat the regulator for those applications where the fuel flow often stops during longer intervals. It is sufficient to apply an electrical heating plate to preheat the regulator connection block. Two 6,5 mm bores in the connection block allow mounting such a heating plate. This heater could work permanently, but it should at least be switched on in time before fuel is supposed to start flowing to achieve correct operation. Maintenance The regulator normally does not require any maintenance. Wear or damage highly depends on fuel quality. The only moving part is the regulator shaft. After a long period of operation, wear on the sleeve or on the regulator shaft can occur, resulting in an increase of leak flow at minimum throughput. After a while some wear may occur on the o-rings. Complete seal sets are available for replacement. In case of wear of the sleeve or of the regulator shaft, it is advised to return the regulator to the factory for repair. It is not recommended to perform this kind of repairs without proper tools and test equipment. The regulator shaft and the sleeve are being manufactured within close tolerances to avoid operation difficulties after such repairs. To exchange the o-rings in the flange, remove the pointer, held by 1 screw. Remove any damages and polish any sharp edges at both ends of the regulating shaft. Remove both flanges, each held by 2 screws, but leave the regulating shaft in its place. Carefully remove both o-rings from their grooves using a sharp needle without damaging the flanges in any way. Before re-assembly, make sure all parts involved are undamaged and perfectly clean. In case the regulator shaft has come out by accident, put it back in the correct position. Otherwise, the regulator will not function at all afterwards. Put the new o-rings in place. Near the o-rings, the regulator shaft should be absolutely free of damages. Re-assemble the regulator in reverse order. The position of the pointer on the regulator shaft has been pre-set at the factory. Both ends of the regulator shaft have a pit for fixing the pointer in the correct position. If the regulator shaft is mounted properly and the pointer is fixed again using this pit, the characteristic of the regulator will not change after replacement of o-rings. © Fluidics Instruments BV Page 2/2 Regulator 24—VK1 24-T201-4G-E 28-09-10 M5x12/17_ (8x) Pointer O-ring 7,66x1,78 06.5 (2x) O-ring 17,17x1,78 Connection block Sleeve Flange Regulatorshaft © Fluidics Instruments BV Page 1/1
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CBM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

CBM FLU | Régulateur pression 24-VK1-2.7

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the CBM FLU34001 pressure regulator in the Philippines?

Source the CBM FLU34001 from 3G Electric Philippines. We supply oil burner regulators with delivery to Manila and Quezon City. 3G Electric handles all logistics and Bureau of Customs documentation — order at www.3g-electric.com.ph or request a quote.

What is the lead time for the CBM FLU34001 regulator?

Lead time depends on current stock and sourcing route. Contact 3G Electric for a specific delivery timeline. We manage customs clearance and inland logistics to ensure timely arrival in the Philippines.

What is the maximum pressure and temperature rating for the CBM FLU34001?

The CBM FLU34001 is rated to 40 bar maximum pressure and handles fuel temperatures up to 140°C. It features M5 threaded bores and 6.5 mm connection holes, suitable for standard oil burner installations.

Used in

Common applications for CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Products

3G Electric supplies CBM oil, fuel & nozzles. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This CASH VALVE steam pressure regulator features a bronze body with FNPTF x FNPTF connections and a 3/8 inch inlet connection size. It is used in steam systems to reduce and maintain downstream pressure, suitable for industrial process heating and commercial boiler installations
CASH VALVE
This CASH VALVE steam pressure regulator features a bronze body with FNPTF x FNPTF connections and a 3/8 inch inlet connection size. It is used in steam systems to reduce and maintain downstream pressure, suitable for industrial process heating and commercial boiler installations
Bronze pressure regulator with 1 in FNPTF inlet and outlet, adjustable outlet pressure from 2 psig to 20 psig, and maximum operating temperature of 180°F. Used to reduce and stabilize pressure in water, air, or non-corrosive fluid systems in commercial plumbing, irrigation, and industrial process control applications
CASH VALVE
Bronze pressure regulator with 1 in FNPTF inlet and outlet, adjustable outlet pressure from 2 psig to 20 psig, and maximum operating temperature of 180°F. Used to reduce and stabilize pressure in water, air, or non-corrosive fluid systems in commercial plumbing, irrigation, and industrial process control applications
AUTOMATIC PRESS.REG. K1.3 M22X1,5
Interpump
AUTOMATIC PRESS.REG. K1.3 M22X1,5
This bronze steam pressure regulator features FNPTF x FNPTF connections with a 1/2 in inlet connection size. It is used to reduce and stabilize high-pressure steam to a lower, consistent outlet pressure for industrial heating, processing, and sterilization systems. Typical applications include steam distribution lines, boilers, and plant utilities
CASH VALVE
This bronze steam pressure regulator features FNPTF x FNPTF connections with a 1/2 in inlet connection size. It is used to reduce and stabilize high-pressure steam to a lower, consistent outlet pressure for industrial heating, processing, and sterilization systems. Typical applications include steam distribution lines, boilers, and plant utilities
This bronze pressure regulator reduces and stabilizes inlet pressure to a set downstream range. It features 1 in FNPTF x FNPTF connections and an adjustable outlet pressure range of 10 psig to 45 psig, with a maximum operating temperature of 180°F. Suitable for water, air, and non-corrosive fluid systems in commercial and industrial applications requiring precise pressure control
CASH VALVE
This bronze pressure regulator reduces and stabilizes inlet pressure to a set downstream range. It features 1 in FNPTF x FNPTF connections and an adjustable outlet pressure range of 10 psig to 45 psig, with a maximum operating temperature of 180°F. Suitable for water, air, and non-corrosive fluid systems in commercial and industrial applications requiring precise pressure control
AUTOMATIC PRESS.REG. K1.3 M22X1,5 NO INJ
Interpump
AUTOMATIC PRESS.REG. K1.3 M22X1,5 NO INJ

More from CBM

View all CBM parts
CBM
CBM
Fuel oil pipe 24-HA-D-700-3/8
CBM
CBM
Disc type 24-E-1.80
CBM
CBM
Oil pipe 24-HA-D-800-2/8
CBM
CBM
Pellet type 24-D-2,00
CBM
CBM
Atomizer type 24-P-13
CBM
CBM
Pellet type 24-D-1.80
CBM
CBM
Disc type 24-D-2.50
CBM
CBM
Pellet type 24-D-3.00