We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Dwyer Miniature current detector MCS-111050 - Measurement
DwyerMeasurement

Dwyer Miniature current detector MCS-111050

The Dwyer MCS-111050 is a miniature current detector for electrical monitoring and protection applications, featuring adjustable setpoint and red/green LED indication. Rated for 600 V with minimum current detection…

SKU 3G-CBM-02352

Also listed as: DWY 60202 · DWY-60202

Brand
Dwyer
Item
Miniature current detector MCS-111050
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dwyer
core
solid
type
Miniature current detector
model
MCS-111050
housing
UL 94V-0
setpoint
adjustable
indicator
LED red/green
voltage class
600 V
minimum current
0.50 A

Datasheet Content

Détecteur de courant Série CCS Coeur Solide ou Ouvrable, LED de Confirmation Visuelle, Valeur de Consigne Fixe ou Réglable 63/64˝ [25.15] Ø5/32˝ [Ø3.94] 1-21/32˝ [42.25] 1/8˝ [3.18] 2-1/32˝ [51.73] Modèles Solides 2-31/64˝ Modèles Ouvrables [63.03] La Série CCS Détecteur de Courant est idéale pour la surveillance de l’état de SPÉCIFICATIONS fonctionnement des ventilateurs, pompes et moteurs. Ces commutateurs autoalimentés Courant Admissible : de 0 à 200 A AC. peuvent être accrochés ou attachés directement aux câbles ou fils. Pour une utilisation sur des Capacité Nominale Max. du Commutateur : installations existantes, les modèles à boîtier ouvrable peuvent être installés sans déconnection Pour modèles à contact sec : 0.3 A @ 135 VAC/DC ; des câbles. Les indicateurs LED confirment visuellement que le courant traverse bien le cœur. Pour modèles sans contact sec : 1 A @ 240 VAC. Des valeurs de consigne fixes ou réglables sont disponibles. Les modèles réglables utilisent un Besoin en Alimentation : Aucun, autoalimenté. potentiomètre pour faciliter le réglage de la valeur de consigne. Limites de Température : de -30 à +70°C. Limites d’Humidité : 0 à 95% (sans condensation). Valeur de Valeur LED Contact Modèle Boîtier Sec Réf. Tension d’Isolement : 2000 V. Consigne Minimal Sortie Fréquence : 40 à 400 Hz. CCS-121050 Coeur solide Fixe 0.50 Rouge Oui DWY60102 Caractéristiques du Boîtier : UL, 94 V-O d’indice d’inflammabilité, ABS boîtier en plastique. CCS-111100 Coeur solide Réglable 1.00 Rouge/Vert Non DWY60104 Homologations : CE, cUL, UL. CCS-221100 Coeur ouvrable Fixe 1.00 Rouge Oui DWY60106 CCS-211150 Coeur ouvrable Réglable 1.50 Rouge/Vert Non DWY60108 CCS-131100 Coeur solide Réglable 1.00 Rouge/Vert Oui DWY60110 CCS-231150 Coeur ouvrable Réglable 1.50 Rouge/Vert Oui DWY60112 Détecteur de courant miniature Série MCS Economique, Coeur Solide ou sans Coeur, LED de Confirmation, Valeur de Consigne Réglable 3-1/2 2-29/32 2X Ø13/64 [89.00] [Ø5.00] 2X [74.00] 1-17/64 Ø13/64 63/64 45/64 [32.00] [Ø5.00] [25.00] [18.00] 2-3/4 43/64 33/64 2-31/64 33/64 19/32 [17.00] [63.00] [70.00] [13.00] [13.00] [15.00] 1-9/64 Ø3/4 [Ø19.00] 55/64 2-33/64 [29.00] 2-7/16 [64.00] [62.00] [22.00] 55/64 [22.00] 55/64 3-1/2 [22.00] [89.00] 4-1/64 Cœur Solide Sans Coeur [102.00] Cœur Solide Sans Coeur La Série MCS Miniature Détecteur de Courant Miniature est idéale pour la SPÉCIFICATIONS surveillance du courant dans les boîtiers de fusibles et les petits panneaux de contrôles. Les Courants Admissibles : deux modèles ont des valeurs de consigne réglables et une indication en LED pour renseigner MCS-111050 : de 0.5 à 50A en continu ; sur la présence de courant dans l’appareil et sur l’état d’activation du commutateur. Les MCS-111001 : de 0.01 à 1A en continu. valeurs de consigne peuvent être réglées par le biais d’un potentiomètre proche des LED. Du Puissance de Sortie : Isolé, N.O. 0.3 A @ 130 V DC/AC. fait de la taille du commutateur, il n’existe que des versions sans cœur ou à cœur solide. La Besoin en Alimentation : Aucun, autoalimenté. version sans cœur a un bloc de jonction capable de recevoir, directement dans l’appareil, du Hystérésis : 1%. courant jusqu’à 1A. Temps de Réponse : <200 ms. Limites de Température : de 0 à +50°C. Limites d’Humidité : de 10 à 95% RH (sans condensation). Modèle Boîtier Valeur de Valeur LED Réf. Consigne Minimal Caractéristiques du Boîtier : UL 94V-0 MCS-111050 Coeur solide Réglable 0.50 Rouge/Vert 3G-CBM-02352 Indice d’inflammabilité ABS, classe d’isolation 600 V. Poids : 14.5 g. MCS-111001 Sans coeur (Bloc de jonction) Réglable 0.01 Rouge/Vert DWY60204 Homologations Officielles : CE, RoHS, UL. RoHS

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer MCS-111050 is a miniature current detector for electrical monitoring and protection applications, featuring adjustable setpoint and red/green LED indication. Rated for 600 V with minimum current detection of 0.50 A, it fits industrial control and safety systems requiring compact overcurrent sensing.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Dwyer MCS-111050 current detector in the Philippines?

3G Electric Philippines supplies the Dwyer MCS-111050 current detector with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation and logistics. Contact us for availability and PHP invoicing on orders for industrial control and electrical protection applications.

What is the lead time for the Dwyer MCS-111050?

Lead time for the Dwyer MCS-111050 is available on request. As an authorized distributor, 3G Electric sources directly and manages customs clearance to the Philippines. Delivery to CALABARZON industrial zones and Metro Manila is standard.

What is the minimum current detection rating of the Dwyer MCS-111050?

The Dwyer MCS-111050 detects minimum current of 0.50 A at 600 V rated voltage. It features adjustable setpoint and red/green LED indication for overcurrent protection in industrial control and safety systems requiring compact, reliable electrical monitoring.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Miniature current detector MCS-111001
Dwyer
Dwyer
Current detector CCS-111100
Current detector CCS-211150
Dwyer
Current detector CCS-211150
Current detector CCS-121050
Dwyer
Current detector CCS-121050
Dwyer
Dwyer
Current detector CCS-231150
Dwyer
Dwyer
Current detector SCS-111100-R

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203