We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
DwyerMeasurement

Dwyer Average flow probe PAFS-1003

The Dwyer PAFS-1003 is an average flow probe with four detection points for fluid measurement applications. Built from ABS/polycarbonate material rated UL94-5V, it accommodates 6 mm ID tubing and operates from 4 to…

SKU 3G-CBM-02225

Also listed as: DWY 30004 · DWY-30004

Brand
Dwyer
Item
Average flow probe PAFS-1003
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dwyer
model
PAFS-1003
material
ABS/polycarbonate (UL94-5V)
tubing id mm
6
tubing od mm
10
detection points
4
temperature storage
-40 to +60°C
temperature operational
4 to 49°C

Datasheet Content

Sonde de débit moyen Idéal pour la mesure de débit de ventilation La Série PAFS-1000 Sonde de Debit Moyen est indiquée pour détecter une pression différentielle dans la section d’entiée d’unités terminales a volume d’cit variable et d’unités terminales de ventilation. Les appareils peuvent également étre utilisés pour détecter la pression différentielle en d‘autres endroits des systémes de conduite principaux et secondaires. Le port “H” détecte la pression totale tandis que le port “L” détecte la pression statique. La différence entre ces signaux correspond au différentiel, ou pression dynamique. Pour les modéles de PAFS-1002 @ PAFS-1005, jusqu’d quatte points de détection et des longueurs de 8.02 4 25.26 cm sont disponibles pour adapter le diamtre de Ia boite de 10.16 € 40.64 cm. Pour les modéles de PAFS:1006 a PAFS -1011, jusqu’t dix points de détection et des longueurs de 31.75 & 60.72 cm sont disponibles pour adapter les dimensions de conduite Gi une taille adéquate, SPECIFICATIONS Service : Air et gaz compatible. Matériaux : ABS/polycarbonate (UL94-5V). Limites de Température : Opérationnelle : de 4 4 49°C ; Stockage : de -40 4 +60°C. Raccord : 6 mm ID, 10 mm OD de tubage. Position de Montage : Bride intégrale avec joint. Poids : 28 g. MOUNTING HOLES 2X03/16 [04.76] PUSH-ON CONNECTIONS: Bp FOR 3/8 POLY TUBING [9.53 OD] 3/4 mae FOAM GASKET 1/8 THK [6.35 THK] 3178] APPLICATIONS Contidle de zone dans les systémes HVAC. Modeéle Longueur (Dimension A) Ref. PAFS-1002 | 8.02 cm WwY30002 PAFS-1003 | 13.73 cm WY30004 PAFS-1004 | 19.55 cm WY30006 PAFS-1005 | 25.26 cm WwY30008 PAFS-1006 | 31.75 cm WY30010 PAFS-1007 | 37.47 cm WY30012 PAFS-1008 | 43.50 cm WwY30014 PAFS-1009 | 49.29 cm WY30016 PAFS-1010 | 55.0] cm WY30018 PAFS-1011 | 60.72 cm wy30020 Dwyer

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer PAFS-1003 is an average flow probe with four detection points for fluid measurement applications. Built from ABS/polycarbonate material rated UL94-5V, it accommodates 6 mm ID tubing and operates from 4 to 49°C. Suitable for process monitoring and flow verification systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Dwyer PAFS-1003 flow probe in the Philippines?

3G Electric Philippines supplies the Dwyer PAFS-1003 average flow probe with delivery to Manila and Quezon City. We handle all logistics, Bureau of Customs documentation, and PHP invoicing. Contact us for availability and lead times.

What is the lead time for the Dwyer PAFS-1003?

Lead time on request. 3G Electric sources the Dwyer PAFS-1003 from authorized distributors. We arrange delivery to the Philippines, manage import documentation, and coordinate logistics to your facility in CALABARZON or Metro Manila.

What tubing size does the Dwyer PAFS-1003 accommodate?

The PAFS-1003 is designed for 6 mm ID tubing with 10 mm OD. It features four detection points for accurate flow measurement and operates between 4 to 49°C. Material is ABS/polycarbonate, rated UL94-5V for safety.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Average flow probe PAFS-1004
Dwyer
Average flow probe PAFS-1004
Dwyer
Dwyer
Average flow probe PAFS-1005
Dwyer
Dwyer
Average flow probe PAFS-1008
Dwyer
Dwyer
Average flow probe PAFS-1007
Dwyer
Dwyer
Average flow probe PAFS-1010
Average flow rate probe PAFS-1006
Dwyer
Average flow rate probe PAFS-1006

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203