We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
DwyerMeasurement

Dwyer External temperature probe TE-RND-B

Dwyer external temperature probe TE-RND-B delivers IP65-rated measurement in industrial environments with radiant heat protection and polycarbonate housing, ideal for HVAC and process monitoring applications…

SKU 3G-CBM-02332

Also listed as: DWY 54016 · DWY-54016

Brand
Dwyer
Item
External temperature probe TE-RND-B
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dwyer
ip rating
IP65
protection
radiant heat protection
housing material
polycarbonate

Datasheet Content

Sondes de température extérieures Série TE-OND / TE-RND Protection Contre la Chaleur Rayonnante, Boîtier IP65 5-1/8 4-17/32 2-15/64 4-17/32 [130.18] [115.09] [56.75] [115.09] 3-1/8 3-1/8 1-13/64 [79.38] [79.38] [30.56] Ø3/16 [4.76] 6-25/32 MOUNTING HOLES [172.09] TYP 4 PLCS 55/64 [21.83] Ø5-1/8 [130.18] Ø4-47/64 [120.25] 4-31/32 [126.21] 8-51/64 8-43/64 [223.30] [220.27] 3-45/64 [93.98] 2-1/4 5-1/8 [57.15] [130.05] La Série TE-OND/TE-RND Sondes de Température d’Air Extérieur est livrée Résistance vs Tableau de Température dans deux configurations différentes pour augmenter la précision des mesures en réduisant Température Courbes de résistance (Q) les effets de la chaleur rayonnante. Pour les applications où la face nord du bâtiment est °C °F A B C D E F accessible, le TE-OND peut être utilisé pour protéger contre les niveaux faibles de chaleur -55 -67.0 607800.00 963849.00 289154.70 78.32 783.2 2394000.00 rayonnante. Si la sonde doit être montée directement à la lumière du soleil ou si une mesure -50 -58.0 441200.00 670166.00 201049.80 80.31 803.1 1646200.00 plus précise est nécessaire, nos six plaques de protection radiative se montent au-dessus de -45 -49.0 323600.00 471985.00 141595.50 82.29 822.9 1145800.00 la sonde de température. Les modèles de protection aux radiations peuvent être posés en -40 -40.0 239700.00 336479.00 100943.70 84.27 842.7 806800.00 surface ou montés par tuyau. Tous les modèles incluent des blocs de jonction amovibles pour -35 -31.0 179200.00 242681.00 72804.30 86.25 862.5 574400.00 une liaison facilitée. -30 -22.0 135200.00 176974.00 53092.20 88.22 882.2 413400.00 -25 -13.0 102900.00 130421.00 39126.30 90.19 901.9 300400.00 -20 -4.0 78910.00 97081.00 29124.30 92.16 921.6 220600.00 SPÉCIFICATIONS -15 5.0 61020.00 72957.00 21887.10 94.12 941.2 163500.00 Précision : -10 14.0 47540.00 55329.00 16598.70 96.09 960.9 122280.00 Capteur de température – thermistance : ±0.2°C @ 25°C ; -5 23.0 37310.00 42327.00 12698.10 98.04 980.4 92240.00 Capteur de température – RTD : DIN classe A : ±0.15°C @ 0°C. 0 32.0 29490.00 32650.00 9795.00 100.00 1000.0 70160.00 Limites de Température : Opérationnelle : de -40 à +150°C. 5 41.0 23460.00 25392.00 7617.60 101.95 1019.5 53780.00 Courbes de la sonde : voir résistance vs. Tableau de température. 10 50.0 18780.00 19901.00 5970.30 103.90 1039.0 41560.00 Matériel du Boîtier : Polycarbonate. 15 59.0 15130.00 15712.00 4713.60 105.85 1058.5 32340.00 Caractéristiques du Boîtier : IP65. Poids : 295 g. 20 68.0 12260.00 12493.00 3747.90 107.79 1077.9 25360.00 25 77.0 10000.00 10000.00 3000.00 109.74 1097.4 20000.00 30 86.0 8194.00 8057.00 2417.10 111.67 1116.7 15892.00 Modèle Type de Sonde Réf. 35 95.0 6752.00 6531.00 1959.30 113.61 1136.1 12704.00 TE-OND-A thermistance 10K Ω type III DWY54002 40 104.0 5592.00 5326.00 1597.80 115.54 1155.4 10216.00 TE-OND-B thermistance 10K Ω type II DWY54004 45 113.0 4655.00 4368.00 1310.40 117.47 1174.7 8264.00 50 122.0 3893.00 3602.00 1080.60 119.40 1194.0 6722.00 TE-OND-C thermistance 3K Ω DWY54006 55 131.0 3271.00 2986.00 895.80 121.32 1213.2 5498.00 TE-OND-D RTD PT100 Ω DWY54008 60 140.0 2760.00 2488.00 746.40 123.24 1232.4 4520.00 TE-OND-E RTD PT1000 Ω DWY54010 65 149.0 2339.00 2083.00 624.90 125.16 1251.6 3734.00 TE-OND-F thermistance 20K Ω DWY54012 70 158.0 1990.00 1752.00 525.60 127.08 1270.8 3100.00 75 167.0 1700.00 1480.00 444.00 128.99 1289.9 2586.00 TE-RND-A thermistance 10K Ω type III DWY54014 80 176.0 1458.00 1255.00 376.50 130.90 1309.0 2166.00 TE-RND-B thermistance 10K Ω type II 3G-CBM-02332 85 185.0 1255.00 1070.00 321.00 132.80 1328.0 1822.60 TE-RND-C thermistance 3K Ω DWY54018 90 194.0 1084.00 915.50 274.65 134.71 1347.1 1540.00 TE-RND-D RTD PT100 Ω DWY54020 95 203.0 939.30 786.60 235.98 136.61 1366.1 1306.40 100 212.0 816.80 678.60 203.58 138.51 1385.1 1112.60 TE-RND-E RTD PT1000 Ω DWY54022 105 221.0 712.60 587.60 176.28 140.40 1404.0 951.00 TE-RND-F thermistance 20K Ω DWY54024 110 230.0 623.60 510.60 153.18 142.29 1422.9 815.80 115 239.0 547.30 445.30 133.59 144.18 1441.8 702.20 120 248.0 481.80 389.60 116.88 146.07 1460.7 606.40 125 257.0 425.30 341.90 102.57 147.95 1479.5 525.60 130 266.0 376.40 301.00 90.30 149.83 1498.3 N/A 135 275.0 334.00 265.80 79.74 151.71 1517.1 N/A…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dwyer external temperature probe TE-RND-B delivers IP65-rated measurement in industrial environments with radiant heat protection and polycarbonate housing, ideal for HVAC and process monitoring applications requiring reliable external sensing.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Dwyer TE-RND-B temperature probe in the Philippines?

3G Electric Philippines supplies the Dwyer TE-RND-B external temperature probe for delivery to Manila, Quezon City, and across the Philippines. We handle all logistics, customs documentation, and Bureau of Customs clearance. Contact us for availability and lead-time on request.

What is the lead time and shipping for the Dwyer TE-RND-B in the Philippines?

Lead time varies based on current stock and import status. 3G Electric manages all logistics to your location in the Philippines, including customs brokerage. Contact our team for a specific lead-time quote on the TE-RND-B.

What is the IP rating and housing material of the Dwyer TE-RND-B?

The Dwyer TE-RND-B delivers IP65 protection, making it suitable for wet industrial environments. It features a polycarbonate housing with radiant heat protection, ideal for HVAC and process monitoring applications requiring reliable external sensing.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
External temperature probe TE-RND-C
Dwyer
Dwyer
Outside temperature probe TE-RND-E
Dwyer
Dwyer
Outdoor temperature probe TE-RND-D
Outdoor temperature probe TE-RND-F
Dwyer
Outdoor temperature probe TE-RND-F
Dwyer
Dwyer
External temperature probe TE-OND-C
Dwyer
Dwyer
Outdoor temperature probe TE-RND-A

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203