We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
DSZHHVAC Tools

DSZH 29007010 clamp ammeter

DSZH clamp ammeter measures AC/DC current up to 1000 A with 13 mm LCD display and multiple ranges including voltage, resistance, and temperature. Designed for HVAC technicians and field electricians requiring…

SKU 3G-CBM-01576

Also listed as: COR 40302 · COR-40302

Brand
DSZH
Item
29007010 clamp ammeter
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DSZH
display
13 mm LCD, 3.5 digits
power consumption
11 mA DC
conductor jaw size
78.5 mm
measurement ranges
ACA, DCA, ACV, DCV, ohms, diode, temperature
operating humidity
less than 80% RH
max current dca aca
1000 A
operating temperature
0 to 50°C

Datasheet Content

DCA/ACA, 1000 A, Peak hold, Temperature DIGITAL CLAMP METER Model : DM-6055C ISO-9001, CE, IEC1010 1000A, ACA/DCA CLAMP METER ( with ℃ TEMP. ) Model : DM-6055C 1000A, ACA/DCA CLAMP METER ( with ℉ TEMP. ) Model : DM-6055F FEATURES * Measure max. 1000 A DCA or ACA by the inductive * LCD display, easy & clear readout. conductor, contactless. * High internal impedance, assures min. measuring error. * Design meet IEC 1010 safety requirement. * LSI-circuit provides high reliability and durability. * Multi-functions for ACA, DCA, ACV, DCV, ohms, * Built-in low battery indicator. Diode, Temperature. * Overload protection circuit is provided for all range. * Built-in Data Hold function. * Compact & heavy duty ABS housing plastic case. * Built-in Peak Hold function for measuring transient signal. GENERAL SPECIFICATIONS Display 13 mm (0.5") LCD, 3 1/2 digits. Power Approx. DC 11 mA. Max. indication 1999. Consumption Measurement ACA, DCA, ACV, DCV, ohms, Operating Temp. 0 ℃ to 50 ℃(32 ℉ to 122 ℉) Range & Data hold, Peak Hold, Operating Less than 80% RH. Temperature. Humidity Polarity Automatic Switching, " - " indicates Weight 400 g/0.90 LB (including battery). negative polarity. Dimension 230 x 70 x 36 mm (9.1 x 2.8 x 1.4 inch) Current Sensor Hall effect sensor. Conductor Jaw 78.5 mm ( 3.1 inch ) - outside Zero adjustment DCA External knob, for DCA zero Size adjustment. Accessories Test lead (red & black)..............1 Pair Others Automatic adjustment. Operation manual..................... 1 PC. Over-input Display shows '1' or '-1'. Carrying case ...........................1 PC. Sampling Time Approx. 0.4 second. TP-01 Thermocouple probe with Battery Heavy duty type, DC 9V battery. 006P, plug.........................................1 PC. MN1604 ( PP3 ) or equivalent. ELECTRICAL SPECIFICATIONS ( 23± 5 ℃ ) Function Range Resolution Accuracy Overload Circuit Remark Protection DC Voltage 200 V 0.1 V ± ( 0.8 % + 1 d ) AC/DC 600 V. Input impedance 600 V 1V 10 Megaohm AC Voltage 200 V 0.1 V ±(1%+2d) AC/DC 600 V. Input impedance ( 50/60Hz ) 600 V 1V 10 Megaohm Resistance 2000 ohm 1 ohm ±(1%+1d) AC/DC 400 V AC/DC 200 A 0.1 A ± ( 1.5 % + 10 d ) AC/DC 1000 A ACA Spec. Current 1000 A 1A ±(2%+5d) test on 60 Hz/50 Hz. Temp. -40 ℃ to 1 ℃ 0 to 750 ℃ :± ( 1 % + 2 ℃ ) ℃ Model 750 ℃ 0 to -20 ℃ : typ.± 2 ℃ (DM-6055C only) -20 to -40 ℃ : typ.± 3 ℃ Temp. -40 ℉ to 1 ℉ 32 to 1400 ℉ : ± ( 1.2 % + 3 ℉ ) ℉ Model 1400 ℉ 1400 to 1800 ℉:typ.± (2 % + 3℉) (DM-6055F only) 32 ℉ to -4 ℉ : typ. ± 4 ℉ -4 ℉ to -40 ℉ : typ.± 6 ℉ Diode Check Short/non conductance, good/defect test. Approx. diode VF ( forward voltage ). Peak Hold Acquisition Time : 150 ms, Accuracy : 3%, Display Decay Rate : < 2 digits/sec. Application : Use for measuring transient signal for current . Data Hold Available for all functions to keep the data hold on the display . Remark * Input impedance for ACV & DCV range is 10 Mega ohm. * ACA, ACV frequency response is from 40 to 400 Hz. * ACA, ACV specification be tested on sine wave 50/60 Hz. THERMOCOUPLE PROBE (type K) TP-01 -40 ℃ to 250 ℃ ( 300 ℃ short- term ). TP-03 -50 ℃ to 1200 ℃ ( -50 ℉ to 2200 ℉ ). Ultra fast response naked-bead probe. High temperature, Penetration & immersion. TP-02A -50 ℃ to 900 ℃ ( -50 ℉ to 1650 ℉ ). TP-04 -50 ℃ to 400 ℃ ( -50 ℉ to 752 ℉ ). Penetration & Immersion applications. Precision surface temp. measurement usage. * Remark : TP-01 is the standard accessory of the DM-6055C, DM-6055F. TP-02A, TP-03, TP-04 are optional.

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH clamp ammeter measures AC/DC current up to 1000 A with 13 mm LCD display and multiple ranges including voltage, resistance, and temperature. Designed for HVAC technicians and field electricians requiring portable current measurement in environments up to 50°C.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the DSZH 29007010 clamp ammeter in the Philippines?

3G Electric Philippines supplies the DSZH 29007010 clamp ammeter with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for availability and a quote.

What is the lead time for the DSZH clamp ammeter order?

Lead time on request. 3G Electric sources the DSZH 29007010 globally and arranges delivery throughout the Philippines. Exact timing depends on current availability.

What current range does the DSZH 29007010 clamp ammeter measure?

The DSZH 29007010 measures AC and DC current up to 1000 A across multiple ranges. It also measures AC/DC voltage, resistance in ohms, and temperature 0–50°C. The 13 mm LCD display (3.5 digits) shows readings in field conditions.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DSZH
DSZH
Current detector SCS-220150
Rectangular thermometer 29005050
DSZH
Rectangular thermometer 29005050
Thermometer flanged L1500 D100 29005044
DSZH
Thermometer flanged L1500 D100 29005044
Occlusion clamp
DSZH
Occlusion clamp
Vacuum gauge D80 0/-1000mbar
DSZH
Vacuum gauge D80 0/-1000mbar
DSZH
DSZH
Laser tachometer 290034006

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)