We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

COFI Oil transformer TRK2-35 with cable - Ignition Transformers
COFIIgnition Transformers

COFI Oil transformer TRK2-35 with cable

Cofi TRK2-35 is an oil-filled ignition transformer for industrial ignition systems, delivering 12000 V secondary output from 220-240 V primary input at 50/60 Hz. It features a 3x0.50 mm PVC cable with 380 mm length…

SKU 3G-CBM-01199

Also listed as: COF 05036 · COF-05036

Brand
COFI
Item
Oil transformer TRK2-35 with cable
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

COFI
type
ignition transformer
model
TRK2-35
volts
2x12000
cable type
3x0.50 PVC
tension v
220
cable length
380 mm
primary voltage
220-240 V
internal material
epoxy thermosetting resin
primary frequency
50/60 Hz
enclosure material
PBT
secondary voltage peak
12000 V

Datasheet Content

DATA SHEET TRK2-35 Description: TRK2 220-240V 50/60Hz SP GENERAL CHARACTERISTICS The ignition transformer is CE marked, it is made in compliance with the European product standard EN 61588/2/3. It undergo to the European low voltage directives 2006/95/CE and electromagnetic compliance 2004-108-CE. By using the advised accessories the transformer is compliant with the prescription of the generic standard EN 50081-1 and in particular with the electronic home device standard EN 55014-1/A2. Every single transformer, at the end of its production cycle, is tested as reported on the table below. The ignition transformer shall be used with a control unit. The gap between the electrodes shall be from 2,5 to5 mm. An high voltage symbol with yellow color filling has to be applied outside of the device where the transformer is mounted. RATED DATA Primary Supply Voltage E [V]+10 -15 220-240 Frequency [Hz] 50/60 Primary Current [A] 0.275 Apparent Power [VA] 63 Secondary Voltage at open circuit RMS [kV ]±10% 2x10 Secondary frequency [kHz] 10 su 100Hz Secondary Current in short circuit RMS [mA] ±10% 35 Duty Cycle 50% in 2 min. Temperature data: Temperature Class: B Operating Ambient Temperature (EN61558/2/3): [°C] +60/-20 Approvals: CE MECHANICAL DATA Drawing File: K2 External enclosure: PBT Inside :epoxy thermosetting resin H.V. connections : plug Ø 4 mm. Packaging: 20 pcs. Box Storage temperature -20/+85°C Transformer weight [kg.]: 0.32 Primary connection type: Plug Description:3x0,50 PVC cable Finishing: Spina D Lenght X [mm]: 380 End terminals: DIMENSIONS 73,60 8 60,50 4 56,50 36 38 5,17 19,60 17 27 63 85 UFFICIO TECNICO DISEGNATO: Paolo Comin DATA: 27/01/2011 MODIFICATO IL: TRK2-35_T2e MODIFICHE: type TRK1-20C TRK1-30C TRK1-40C TRK1-35 TRK2-35 TRK2-45 TRK2-60 7Z centre a la masse, Vv 220-240 220-240 220-240 220-240 220-240 220-240 220-240 entrées sorties Code SPV Fiche 0 4 {profondeur 13,5 mm) — (profondeur 13,5 mm) Transformateur construit avec la technologie électroni- que de l’oscillation @ haute fréquence appliquée 4 une bobine élévatrice de tension imprégnée sous vide. Les caractéristiques de ce transformateur le rendent parti- culiérement adapté dans les brdleurs 4 gaz et 4 gas-oil nécessitant une puissance continue associée a des dimensions et a des poids plus contenus par rapport au transformateur inductif traditionnel. Il est construit centre a la masse Tension Secondaire de créte kV au Secondaire | Service | Poids Fiche K Code SPO Fiche o 4 dans les versions avec les tensions d’alimentation les plus utilisées dans les principales régions du monde ainsi que dans la version 4 12 V. Le transformateur est muni d’un systéme de filtration des parasites incorporé qui, associé aux cables en fibre de carbone, Je rend con- forme aux prescriptions EN55014 de compatibilité électromagnétique analysées dans notre laboratoire avec une instrumentation homologuée. Intensité Hamologation mA. ED% min.| kg DB 100% DB 100% « DB 100% ic AB 33% 3min «€ AB 33% 3min iG AB 33% 3min «€ B33% 3rin « Tableau aux valeurs standard, Sur demande du client, nous pouvons réaliser des tensions d’alimentation spéciales aussi bien & 50 Hz qu'é 60 Hz, 100V- 120V - 200V - 400V -12V H.W. Half Wave (Out 50 Hz) EW: Full Wave (Out 100 Hz) CED 100% Continuous $: Soulagé vue de face mesures techniques vue de cété perspective
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

COFI Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Cofi TRK2-35 is an oil-filled ignition transformer for industrial ignition systems, delivering 12000 V secondary output from 220-240 V primary input at 50/60 Hz. It features a 3x0.50 mm PVC cable with 380 mm length and epoxy resin construction for reliable burner and combustion applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the COFI TRK2-35 ignition transformer in the Philippines?

3G Electric Philippines supplies the COFI TRK2-35 for delivery to Manila and Quezon City. We handle Bureau of Customs documentation and logistics. Contact us for availability and PHP quotation on this 12000 V ignition transformer with 380 mm PVC cable.

What is the lead time and shipping for the TRK2-35 transformer to the Philippines?

Lead time on request. 3G Electric coordinates all delivery logistics and customs clearance to the Philippines. The TRK2-35 is available to order with full technical support and duty documentation included.

What are the primary and secondary voltage specifications of the COFI TRK2-35?

The COFI TRK2-35 delivers 12000 V peak secondary output from a 220-240 V primary input at 50/60 Hz. It includes a 3x0.50 mm PVC cable (380 mm length) and epoxy thermosetting resin enclosure—ideal for burner and combustion ignition systems.

Used in

Common applications for COFI
Gas burner combustion — TRS 515 PC/S, TRS 610 PC/S, TRS 830 P/S ignition transformers for spark generation in small to large capacity gas-fired heaters and boilers.
Oil-fired heating systems — TRE 820/S1 oil-immersed transformer for reliable ignition in heavy fuel oil and light fuel oil burners in industrial plants.
Dual-fuel burner control — TRS 610 PC/S for burners switchable between gas and oil, requiring consistent high-voltage spark across both fuel modes.
Burner retrofit and maintenance — Replacement ignition transformers and mounting kits for aging or damaged combustion control systems in existing boiler houses.
High-voltage spark generation — TRG 1035/S dual-output transformer for complex ignition circuits requiring multiple spark electrodes or redundant ignition paths.
Panel-mounted combustion control — Column 12X38 and Spina cable assemblies for compact transformer installation in enclosed burner management control panels.

COFI Products

3G Electric supplies COFI ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dongan
Dongan
Dongan 50-0500-052, single-phase control transformer, 500 VA
Dongan
Dongan
Dongan IC-0500-106, single-phase control transformer, 500 VA
Dongan
Dongan
Dongan IC-0500-110, single-phase control transformer, 500 VA
Dongan
Dongan
Dongan 50-0500-134, single-phase control transformer, 500 VA
Dongan
Dongan
Dongan IC-0500-109, single-phase control transformer, 500 VA
Dongan
Dongan
Dongan HC-0500-4400, single-phase control transformer, 500 VA

More from COFI

View all COFI parts
COFI
COFI
Transformer type AR1
COFI
COFI
Transformer TD2 LT CSF Oil 2x12kw
Fuel transformer TRS 820/2/J
COFI
Fuel transformer TRS 820/2/J
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
COFI
Transformer type TC1 LTCA
COFI
COFI
Transformer TD2 ST PAF oil 2x12KV
COFI
COFI
Transformer type T11 110 volts
Oil transformer TRS 1030/S
COFI
Oil transformer TRS 1030/S