We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
COFIIgnition Transformers

COFI Transformer TD2 ST PAF oil 2x12KV

Cofi Transformer TD2 ST PAF is a high-voltage ignition transformer for forced draught gas and oil burners, delivering dual 12 kV output from 220-240 V 50/60 Hz supply with 50% duty cycle in 2 minutes. Suitable for…

SKU 3G-CBM-06955

Also listed as: TRF 05105 · TRF-05105

Brand
COFI
Item
Transformer TD2 ST PAF oil 2x12KV
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

COFI
duty cycle
50% in 2 minutes
applications
forced draught burners gas and oil
ignition type
high frequency electronic oscillator with ferrite core
output voltage
12 kV dual output
supply voltage
220-240 V 50/60 Hz
protection fuse
F1A 250V

Datasheet Content

ELECTRONIC IGNITION DESCRIPTION TRANSFORMERS FOR NON- These ranges of electronic ignition transformers are characterized by extremely limited overall dimensions and are PERMANENT OPERATION particularly suitable to equip forced draught burners for gas and light or heavy oil, for civil and industrial applications. The working principle is based on a high frequency electronic oscillator; the voltage it generates is then increased by using a TC....A. Series transformer with ferrite nucleus, reaching in this way output voltage values up to 15 kV. All types can be supplied with filter to minimize the emission of electromagnetic interference. In this way this series of electronic transformers is in compliance with the EMC directive 2014/30/EU without the use of external filters. The transformers of this series can also be supplied for permanent operation (100% duty cycle). For further information see relevant data sheets (TC….S. and TD….S.). FEATURES Followings are the main features of these ranges of transformers: − available with inbuilt EMC filter; − limited weight and overall dimensions; − high efficiency and ignition power; − low consumption; − single-pole or double-pole high voltage output; TD....A. Series − different fixing and connecting systems; − inbuilt protection against short circuit; − in oil and gas burners, the safety of ignition transformers depends on the control unit. APPROVALS − The transformers comply with the essential requirements of the "Low Voltage Directive (LVD) 2014/35/EU", as they are approved by IMQ according to the product standards EN 61558-1:2005 + A1:2009 and EN 61558-2-3:2010. Type Voltage Certificate no. TC1...A. 220-240 V 50/60 Hz CA04.03569 TD1...A. TC2...A. 220-240 V 50/60 Hz CA04.03570 TD2...A. – The transformers are also provided with "CB TEST CERTIFICATE No. IT-3904" stating their compliance with the international standards IEC 61558-1 (ed. 1) + am1 and IEC 61558-2-3 (ed. 1). – The transformers type TCxxxxAx and TDxxxxAx 110-120 V, 50/60 Hz are also available in UL approved version with "Certificate Number 20100119-E331308" according to the standards "UL 506 Standard for Specialty Transformers, 13th Edition" and "C22.2 No. 13 Standard for Luminous Tube Signs, Oil or Gas Burner Ignition Equipment 1st Edition". 3409_r07 1/4 TECHNICAL DATA TC1...A - TC1...AF TC2...A - TC2...AF TD1...A - TD1...AF TD2...A - TD2...AF 110-120 220-240 110-120 220-240 Number of poles 1 2 Output peak voltage kV (1) 15 2x12 Rated output voltage kV (4) 5.9 2 x (2.9 ÷ 3.4) 8 2 x (3.8 ÷ 4.3) 8 (UL versions) 2 x 5 (UL versions) Output peak current mA (2) 45 55 Rated output current mA (2) 20 25 27 30 Output voltage frequency kHz (1) 6 6 Output voltage frequency kHz (2) 10 10 Consumption VA (3) 45 55 (1) No-load output and 30 pF load. (2) Short circuit output. (3) 10 mm spark gap. (4) No-load output. - Supply voltage: 220-240 V 50/60 Hz OVERALL DIMENSIONS on request: 110-120 V 50/60 Hz - Protection fuse: The transformer must be powered The TD series differs from the TC series for its more reduced through a fuse with F1A 250V features, overall dimensions; Fig. 1, Fig. 2, Fig. 3 and Fig. 4 show the in compliance with EN 60127 main dimensions of both transformer series. - Duty cycle: approved versions: 50 % in 2 minutes To fix the transformers, screws type M4 or M5 should be used - Operating temperature range: -10 … +60 °C (in the transformers of the TC series, the oval holes enable a - Protection degree: IP00 variation of the fixing wheel base between 57 mm and 64 - Winding class: H mm). - Recommended distance between the electrodes: 3÷5 mm - Max. ignition cable length: 1.5 m TC1L – TC2L - Standard supply cable length: 560 mm Available in double- - Weight: TC series 420 g approx. pole versions only TD series 360 g approx. CONSTRUCTION The working principle based on the use of a high frequency electronic oscillator has enabled to develop a device with limited dimensions and weight, but with high ignition power. The electronic circuit and the transformer with ferrite nucleus are bathed in a special kind of resin with very good thermal conductivity and a specific coefficient of expansion, which ensures high resistance to temperature variations and to the overload due to protracted working. An inbuilt varistor protects the device from possible voltage transients in the mains supply. The transformers of these series are available in different Available in double- pole versions only versions as regards the number of poles, the position of the isolators, the type of connection, the power supply connection Fig. 1 and the availability of an EMC filter; on this subject, see the following scheme: TC1S – TC2S TC/TD X X X X A X Available in double- pole versions only : without EMC filter; F: with EMC filter; A: non-permanent operation (50% duty cycle); C: supplied with cable (Fig. 1, 2, 3 and 4); P: supplied with outlet (Fig. 6 and 7); V: screw fixing system (Fig. 8); T: fixing system with terminal ∅ 4 (Fig. 8); L: lateral isolators (Fig. 1 and 3); S: bottom isolators (Fig. 2 and 4); 1: single pole; 2: double pole; For instance, the designation TC2LVPAF indicates that the Available in double- transformer belongs to the TC series, is provided with two pole versions only lateral isolators, screw fixing system, power supply with outlet, Fig. 2 EMC filter and is for non-permanent operation. 2/4 3409_r07 TD1L - TD2L TC Available in double- pole versions only Fig. 6 Available in double- TD pole versions only Fig. 3 TD1S – TD2S Available in double- pole versions only Fig. 7 The connection of high voltage cables can be of two types, according to the terminals used inside the isolators: connections can be carried out by means of a screw or a cylindrical terminal with 4 mm diameter, as shown in Fig. 8. All connectors, including the ones complete with cable, can be Available in double- supplied on request. pole versions only Fig. 4 CONNECTION These ranges of ignition transformers have been developed in order to be used with control boxes of our own production, which can be mounted on the ignition devices by means of fixing screws type M4x45, as shown in Fig. 5. All transformers can be supplied with cable or supply outlet; see, for instance, Fig. 6 and Fig. 7, which show the dimensions of a transformer provided with supply outlet (with laterals isolators). Type "V" Type "T" TC TD Fig. 8 INSTALLATION − Caution! There might be…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

COFI Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Cofi Transformer TD2 ST PAF is a high-voltage ignition transformer for forced draught gas and oil burners, delivering dual 12 kV output from 220-240 V 50/60 Hz supply with 50% duty cycle in 2 minutes. Suitable for industrial combustion applications requiring reliable electronic ignition.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy COFI TD2 ST PAF ignition transformer in the Philippines?

3G Electric Philippines supplies COFI TD2 ST PAF transformers available to order with delivery to Manila and Quezon City. We handle Bureau of Customs documentation, logistics, and PHP invoicing for all imports.

What is the lead time for COFI TD2 ST PAF ignition transformer delivery?

Lead time varies by stock location. Contact 3G Electric Philippines for specific availability and delivery schedule to your facility in CALABARZON or Metro Manila.

What supply voltage does the COFI TD2 ST PAF require?

The COFI TD2 ST PAF operates on 220-240 V 50/60 Hz supply and delivers dual 12 kV output with a 50% duty cycle in 2 minutes, suitable for forced draught gas and oil burner ignition systems.

Used in

Common applications for COFI
Gas burner combustion — TRS 515 PC/S, TRS 610 PC/S, TRS 830 P/S ignition transformers for spark generation in small to large capacity gas-fired heaters and boilers.
Oil-fired heating systems — TRE 820/S1 oil-immersed transformer for reliable ignition in heavy fuel oil and light fuel oil burners in industrial plants.
Dual-fuel burner control — TRS 610 PC/S for burners switchable between gas and oil, requiring consistent high-voltage spark across both fuel modes.
Burner retrofit and maintenance — Replacement ignition transformers and mounting kits for aging or damaged combustion control systems in existing boiler houses.
High-voltage spark generation — TRG 1035/S dual-output transformer for complex ignition circuits requiring multiple spark electrodes or redundant ignition paths.
Panel-mounted combustion control — Column 12X38 and Spina cable assemblies for compact transformer installation in enclosed burner management control panels.

COFI Products

3G Electric supplies COFI ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dongan
Dongan
Dongan FP12-551, single-phase control transformer, 5.0 kVA
Dongan
Dongan
Dongan FP12-451, single-phase control transformer, 2.0 kVA
Dongan
Dongan
Dongan FP12-651, single-phase control transformer, 10.0 kVA
Dongan
Dongan
Dongan FP12-401, single-phase control transformer, 1.5 kVA
Dongan
Dongan
Dongan FP12-601, single-phase control transformer, 7.5 kVA
Dongan
Dongan
Dongan FP12-501, single-phase control transformer, 3.0 kVA

More from COFI

View all COFI parts
COFI
COFI
Transformer type AR1
COFI
COFI
Transformer TD2 LT CSF Oil 2x12kw
Fuel transformer TRS 820/2/J
COFI
Fuel transformer TRS 820/2/J
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
COFI
Transformer type TC1 LTCA
COFI
COFI
Transformer type T11 110 volts
Oil transformer TRS 1030/S
COFI
Oil transformer TRS 1030/S
COFI
COFI
Transformer type TC1 100%