We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
HoneywellGas Controls

Honeywell Gas block VK 4105 C 1009 U

Honeywell VK 4105 C 1009 U is a gas block for industrial combustion control with 0.73" flanged ports and 105 mm body length. Rated for 145,653 BTU at 2" w.c. (Class B+C) or 99,309 BTU at 1" w.c. (Class B+D)…

SKU 3G-CBM-00437

Also listed as: BLO 05371 · BLO-05371

Brand
Honeywell
Item
Gas block VK 4105 C 1009 U
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Honeywell
inlet outlet
Ø 0.73"/18.6 mm flanged
body length mm
105
voltage options
220-240 Vrac or 24 Vrac
capacity class b c
145653 BTU at 2" w.c.
capacity class b d
99309 BTU at 1" w.c.
valve classification
Class B+C or B+J depending on model

Datasheet Content

VK41..VK81..A/B/C/D GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM INSTRUCTION SHEET SPECIFICATIONS Model VK41.0: 220 ... 240 Vrac VK41.5: 220 ... 240 Vrac without pilot burner connection VK81.0: 24 Vrac VK81.5: 24 Vrac without pilot burner connection Suffix A: fast opening with pressure regulator Suffix B: fast opening without pressure regulator Suffix C: softlite opening with pressure regulator Suffix D: softlite opening without pressure regulator Main gas connection See table 1. 3/ ” or 1/ ” straight or elbow flanges are according to the 8 2 torsion and bending stress of EN 126 group 2 Side outlet (optional) can be mounted directly to a burner manifold. Pilot gas connection (where applicable) M8 x 1 thread for 4 mm outer diameter tubing. Pressure feedback connection APPLICATION Servo pressure regulator has an M5 threaded hole for connection between pressure regulator and combustion chamber of the appliance. The VK41../VK81.. gas controls for Combined Valve and Ignition system (CVI) have specially been developed for Ambient temperature application in gas fired appliances with either intermittent pilot 5 ... 140° F (IP) or direct burner ignition (DBI). Dimensions For this system, the VK41../VK81.. series gas controls have See fig. 1. been designed to have the S4565/S4575/S4585 series ignition control attached directly onto the valve. Pressure regulation function The combined system then provides programmed safe light Class A according to EN 88 up, flame supervision and regulation of gas flow to the main Subject to change without notice. Printed in the Netherlands. Outlet pressure burner and/or pilot burner of the appliance. Outlet pressure is pressure drop across the main burner The VK41.5/VK81.5 series gas controls can also be used as orifice. stand alone in direct burner applications. A plug with an integrated rectifier circuit then has to be used Outlet pressure range (order number 45.900.441--). 0.022 ... 0.29 psi (0.6 ... 8” w.c.) 0.029 ... 0.46 psi (0.8 ... 13“ w.c.) The VK41../VK81.. gas controls can handle the three gas families, manufactured gas, natural gas and LP gas. Maximum inlet pressure 1/ psi The VK41../VK81.. gas controls are approved in accordance 2 with: Minimum regulation capacity AGA; (ANSI Z21.78--1997) 35000 BTU at Dp= 0.0072 psi (0.2” w.c.) accross main burner CGA; (CAN/CGA--6.20--M97, 1997). orifice at 0.5 psi operating pressure maximum. DESCRIPTION Minimum operating gas pressure 0.22 psi (15 mbar) The VK41../VK81.. gas controls hold a first electric on/off Maximum operating gas pressure direct operator for opening the safety valve of class B The Pmax 1/2 psi (35 mbar) indication on the housing of the according to EN 161 and a second electric on/off servo gas control is the maximum inlet pressure at which the gas operator of class C or J according to EN 161. control functions safely. EN1R--9177 0109R1--NE Side outlet 3.74 (95) 1.46 M5 x 0.8(3) 0.24 (6) mm full thread 2.68 (68) (37) Pressure tap (2) 2.44 (62) Adjustable softlite OUT 0.35 STEP STEP 0.94 (9) 0.07 0.98 Hole to connect (24) (22) (25) ignition control/plug 1.34 3.31 (34) (84) 2.68 (68) 0.94 Earth terminal (24) 3.31(84) Side outlet 4.53 (115) (Optional) Pressure feedback Molex 1.1 square pin header…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell VK 4105 C 1009 U is a gas block for industrial combustion control with 0.73" flanged ports and 105 mm body length. Rated for 145,653 BTU at 2" w.c. (Class B+C) or 99,309 BTU at 1" w.c. (Class B+D). Available in 220-240 Vrac or 24 Vrac configurations for boiler and burner applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Honeywell VK 4105 C 1009 U gas block in the Philippines?

3G Electric Philippines is an authorized industrial-equipment distributor. We stock and order the Honeywell VK 4105 C 1009 U gas block with delivery to Manila and Quezon City. We handle Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for pricing and lead-time.

What is the lead time for the Honeywell VK 4105 C 1009 U?

Lead time varies based on voltage configuration (220-240 Vrac or 24 Vrac) and current availability. 3G Electric coordinates with suppliers and handles all Philippine customs clearance. Request a quote for your specific delivery timeline.

What is the maximum BTU capacity of the Honeywell VK 4105 C 1009 U?

The VK 4105 C 1009 U is rated for 145,653 BTU at 2" w.c. (Class B+C) or 99,309 BTU at 1" w.c. (Class B+D). It features a 105 mm body length and 0.73" (18.6 mm) flanged inlet/outlet ports for boiler and burner applications.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas block VK 4105 C 1025 U
Honeywell
Gas block VK 4105 C 1025 U
Gas block VK 4125 A 1009 U
Honeywell
Gas block VK 4125 A 1009 U
Gas block VK 4105 G 1229 U
Honeywell
Gas block VK 4105 G 1229 U
Gas block VK 4105 C 1066 U
Honeywell
Gas block VK 4105 C 1066 U
Gas block VK 4105 G 1062 U
Honeywell
Gas block VK 4105 G 1062 U
Gas block VK 4100 D 1025 U
Honeywell
Gas block VK 4100 D 1025 U

More from Honeywell

View all Honeywell parts
Honeywell
Honeywell
VK 4105 M 2071 U gas block
Honeywell
Honeywell
Gas block VK 4100 C 1000 U
Honeywell
Honeywell
Thermocouple switch V44/46/86/88
Honeywell
Honeywell
Gas block V 8600 C 1053 U
Honeywell
Honeywell
Gas block VK 4105 C 1090 U
Honeywell
Honeywell
Gas block VK 4105 C 1041 U
Gas block VK 4105 N 2039 U
Honeywell
Gas block VK 4105 N 2039 U
Gas block V 4600 D 1001 U
Honeywell
Gas block V 4600 D 1001 U