We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
HoneywellGas Controls

Honeywell Gas block VK 4100 C 1000 U

Honeywell VK 4100 C 1000 U is a gas control block with electric modulating pressure regulator for fuel gas applications. Pilot gas connection features M8 x 1 thread for 4 mm tubing, with outlet pressure range of…

SKU 3G-CBM-00433

Also listed as: BLO 05364 · BLO-05364

Brand
Honeywell
Item
Gas block VK 4100 C 1000 U
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Honeywell
type
gas control with electric modulating pressure regulator
model
VK 4100 C 1000 U
approvals
AGA (ANSI Z21.78-1997), CGA (CAN/CGA-6.20-M97)
pressure feedback
M5 threaded hole
pilot gas connection
M8 x 1 thread for 4 mm tubing
outlet pressure range
5-140°F

Datasheet Content

VK41..VK81..M/N GAS CONTROLS WITH ELECTRIC MODULATING PRESSURE REGULATOR FOR COMBINED VALVE AND IGNITION SYSTEM INSTRUCTION SHEET The build on Modureg V7335 is designed to work together with the W9335 modulating control, W4115 driver, a T7335 thermistor temperature sensor and an advanced range of micro computer based modulating controls. The VK41../VK81..M,N gas controls are approved in accordance with: AGA; (ANSI Z21.78--1997) CGA; (CAN/CGA--6.20--M97, 1997) The VK41../VK81..M/N gas controls can handle the three gas families, manufactured gas, natural gas and LP gas. DESCRIPTION The VK41../VK81..M/N gas control holds a first electric on/off direct operator for opening the safety valve of class B according to EN 161 and a second electric on/off servo operator of class C or J according to EN 161. SPECIFICATIONS APPLICATION Model VK41.0: 220 ... 240 Vrac VK41.5: 220 ... 240 Vrac without pilot burner connection The VK41../VK81..M/N gas controls for Combined Valve and VK81.0: 24 Vrac Ignition system (CVI) have specially been developed for VK81.5: 24 Vrac without pilot burner connection application in gas fired appliances with either intermittent pilot (IP) or direct burner ignition(DBI). Suffix M: fast opening with electric modulating pressure regulator For this system, the VK41../VK81..M/N series gas valves Suffix N: softlite opening with electric modulating pressure have been designed to have the S4565/S4575/S4585 series regulator ignition control attached directly onto the valve. Main gas connection The combined system then provides programmed safe light up, flame supervision and regulation of gas flow to the main See table 1. 3/ ” or 1/ ” straight or elbow flanges are according to the burner and/or pilot burner of the appliance. 8 2 torsion and bending stress of EN 126 group 2 The VK41../VK81..M/N gas control can also be used as stand Side outlet (optional) can be mounted directly to a burner alone in direct burner applications. manifold. A plug with an integrated rectifier circuit then has to be used (order number 45.900.441--). Pilot gas connection (where applicable) The VK41../VK81..M,N gas control with the V7335A electric M8 x 1 thread for 4 mm outer diameter tubing. modulating pressure regulator (Modureg) has the folowing Pressure feedback connection functions: M5 threaded hole for connection between the Modureg and · Servo pressure regulation the combustion chamber of the appliance. Outlet pressure is held at a constant value regardless of fluctuations of input pressure. Ambient temperature 5 ... 140° F · Modulating control Between minimum and maximum outlet pressure gas Dimensions supply to the appliance is dependent on the electrical See fig. 1. signal to the modulating coil. Pressure regulation function · Mechanical limitation of outlet pressure Class A according to EN 88 The minimum and maximum burner pressures are mechanically adjusted to guarantee good burner Outlet pressure performance in case the modulating control should Outlet pressure is pressure drop across the main burner become out of range. orifice. EN1R--9178 0109R1--NE 1.46 (37) 3.74 (95) Side outlet M5 x 0.8(3) 2.68 (68) Pressure tap 0.24 (6) mm full thread 2.44 (62) Adjustable softlite IN OUT Hole to connect 0.98 ignition control/plug (25) 0.35 0.94 (9) 0.86 (24) V1 V2 (22) 1.34 (34) 3.31 (84) 2.68 0.94 (68) (24) Side outlet (Optional) 1.15 4.53 (29) (115) 5.83 Molex 1.1 square (148) pin header Pressure feedback connection 4.45 Pilot outlet (113) 0.94 3.58 (24) (91) 0.94 (24) 1.46 1.46 (37) (37) 0.94 0.98 0.67 (17) 0.94 Inlet (25) Outlet (24) (24) 3.23 (82) 2.65 (65) 1.18 (30) 1.14 (29) Mounting hole (2) 0.31 (8) See table 1. Fig. 1. Dimensional drawing in inch (mm) Table 1. Standard valve connection Outlet pressure range Inlet End outlet Side outlet Body length 0.022 ... 0.29 psi (0.6 ... 8” w.c.) inch (mm) 0.029 ... 0.46 psi (0.8 ... 13” w.c.) Maximum inlet pressure Æ 0.73”/18.6 Æ 0.73”/18.6 ---- 4.13 (105) 1/ psi mm, flanged mm, flanged 2 Minimum regulation capacity Æ 0.73”/18.6 ---- Æ 0.55”/14 4.13 (105) 35000 BTU at Dp= 0.0072 psi (0.2” w.c.) accross main burner mm, flanged mm, flanged orifice at 0.5 psi operating pressure maximum. Internal 3/8” ---- Æ 0.55”/14 4.13 (105) Minimum operating gas pressure ISO 7--1 mm, flanged 0.22 psi Internal 1/2” ---- Æ 0.55”/14 4.13 (105) Maximum operating gas pressure ISO…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell VK 4100 C 1000 U is a gas control block with electric modulating pressure regulator for fuel gas applications. Pilot gas connection features M8 x 1 thread for 4 mm tubing, with outlet pressure range of 5–140°F. AGA and CGA approved for industrial combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Honeywell VK 4100 C 1000 U gas control block in the Philippines?

3G Electric Philippines stocks and sources the Honeywell VK 4100 C 1000 U for delivery to Manila, Quezon City, and nationwide. We handle customs documentation and logistics. Contact us for availability and lead time on this AGA/CGA-approved gas block.

What is the outlet pressure range and pilot gas connection for the Honeywell VK 4100 C 1000 U?

The VK 4100 C 1000 U outlet pressure range is 5–140°F. Pilot gas connection is M8 x 1 thread for 4 mm tubing. Pressure feedback port is M5 threaded hole. It carries AGA (ANSI Z21.78-1997) and CGA (CAN/CGA-6.20-M97) approvals.

What is the lead time for delivery of the Honeywell VK 4100 C 1000 U to the Philippines?

Lead time for the VK 4100 C 1000 U is on request. 3G Electric imports via Bureau of Customs channels to Manila and Quezon City. Provide your delivery address and quantity for a firm quote and schedule.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas block VK 4115 A 1000 U
Honeywell
Gas block VK 4115 A 1000 U
Gas block VK 4100 D 1025 U
Honeywell
Gas block VK 4100 D 1025 U
Gas block VK 4125 A 1009 U
Honeywell
Gas block VK 4125 A 1009 U
Gas block VK 4105 C 1066 U
Honeywell
Gas block VK 4105 C 1066 U
Gas block VK 4105 C 1025 U
Honeywell
Gas block VK 4105 C 1025 U
Gas block VK 4105 G 1229 U
Honeywell
Gas block VK 4105 G 1229 U

More from Honeywell

View all Honeywell parts
Honeywell
Honeywell
VK 4105 M 2071 U gas block
Honeywell
Honeywell
Thermocouple switch V44/46/86/88
Honeywell
Honeywell
Gas block VK 4105 C 1009 U
Honeywell
Honeywell
Gas block V 8600 C 1053 U
Honeywell
Honeywell
Gas block VK 4105 C 1090 U
Honeywell
Honeywell
Gas block VK 4105 C 1041 U
Gas block VK 4105 N 2039 U
Honeywell
Gas block VK 4105 N 2039 U
Gas block V 4600 D 1001 U