We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
AllansonUV Ballasts

Allanson UVB100W-425-120-240V UV Ballast – Program Start

3G-OTH-03004 UV BALLAST – Program Start

SKU 3G-OTH-03004

Also listed as: UVB100W425120240V · UVB100W 425 120 240V

Brand
Allanson
Item
UVB100W-425-120-240V UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Size
5.3″x1.8″x1.10″
Lamps
1 to 2
Weight
0.80 lb
Lamp mA
425
Lamp Type
Standard
Input Lamps
1 to 2
Lamp Length
24″ to 42″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
100

Datasheet Content

[{"filename":"UVB100W-425-120-240V_WEB.pdf","text":"Specifications Guide\n UV Ballasts\nUVB100W-425-120-240V\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W) Current (mA)\n\n GPH843T5L/4P Light Source 1-2 41 425\n GPH1554T5L/4P Light Source 1 75 425\n TUV PL-L36W/4P Philps 1-2 36 440\n TUV 64T5 HE 4P SE Philps 1 75 425\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power Factor: > 95%\nNumber of lamps: 1-2 Output Current: 425mA\nNormal input voltage: 120-240V, +/-10%, 50-60Hz Efficiency: > 90%\nInput current: 0.84A(120V)/0.42A(240V) Lamp Current Crest Factor: 1.7 or less\nInput power: 100W @ full load Striking/Ignition voltage: 1500 volt\nOperating frequency: > 30kHz Filament preheat time: 1.5-2.0 seconds\nEMI requirements: Meet FCC Part 18 Ballast shut down/protection: EOL/OC\nApprovals: UL/cUL Listed, Class “P”, Ambient temperature: 0-40ºC\n Indoor, Type 1 Case maximum temperature: 75ºC\n Sound rating: “A”\n Weight: 0.80 lbs\n\n\nWiring Diagram and Dimensions\n\n 5.3\" (L) x 1.80\" (W) x 1.10\" (H)\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03004 UV BALLAST – Program Start

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03004 UV ballast used for?

The Allanson 3G-OTH-03004 is a program-start UV ballast designed to power 1–2 standard UV lamps, such as GPH843T5L/4P or TUV PL-L36W/4P, for water treatment, air purification, and industrial disinfection systems. It operates at 120–240 VAC and delivers 425 mA output current.

What are the specifications of the Allanson 3G-OTH-03004?

The Allanson 3G-OTH-03004 is a program-start ballast for 1–2 lamps, 425 mA output, 100 W input power, 120–240 VAC input, 50–60 Hz. It features >95% power factor, >90% efficiency, 1.5–2.0 s filament preheat, 1500 V ignition voltage, and UL/cUL Class P approval. Dimensions: 5.3" x 1.8" x 1.1". Weight: 0.80 lb.

Where to buy the Allanson 3G-OTH-03004 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03004 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this program-start ballast for industrial UV systems.

How to install the Allanson 3G-OTH-03004 UV ballast?

Install the Allanson 3G-OTH-03004 in a dry, indoor location with ambient temperature 0–40 °C. Connect input voltage (120–240 VAC, 50–60 Hz) per the wiring diagram. Ensure proper lamp matching (425 mA, 1–2 lamps) and secure the potted case. Follow local electrical codes and the manufacturer's instructions.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB50W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB60W-425-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB30W-425-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start