Allanson UVB60W-425-24VDC UV Ballast – Program Start

3G-OTH-03048 UV BALLAST – Program Start

SKU 3G-OTH-03048

Also listed as: UVB60W42524VDC · UVB60W 425 24VDC

Brand
Allanson
Item
UVB60W-425-24VDC UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Size
8.5″x2.2″x1.75″
Lamps
1
Weight
2.55 lb
Lamp mA
425
Lamp Type
Standard
Input Lamps
1
Lamp Length
24″ to 48″
Potted Case
Yes
Input Voltage
24V
Input Wattage
60

Datasheet Content

[{"filename":"UVB60W-425-24VDC_WEB.pdf","text":"Specifications Guide\n UV Ballasts\nUVB60W-425-24VDC\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W) Current (mA)\n\n GPH254T5L/4P Light Source 1 14 425\n GPH436T5L/4P Light Source 1 21 425\n GPH843T5L/4P Light Source 1 41 425\n GPH1148T5L/4P Light Source 1 55 425\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Efficiency: > 90%\nNumber of lamps: 1 Ballast shut down/protection: EOL/OC\nNormal input voltage: 24VDC, +/-10% Ambient temperature: 0-40ºC\nInput current: 2.6A Case maximum temperature: 75ºC\nInput power: 60W @ full load Sound rating: “A”\nOperating frequency: > 35kHz Weight: 2.55 lbs\nApprovals: UL/cUL Listed, Class “P”\n\n\n\n\nWiring Diagram and Dimensions\n Dimensions: 9.47\" (L) x 2.29\" (W) x 1.67\" (H)\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03048 UV BALLAST – Program Start

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03048 UV ballast used for?

The Allanson 3G-OTH-03048 is a program-start UV ballast designed to power single standard UV lamps, such as GPH254T5L/4P, GPH436T5L/4P, GPH843T5L/4P, and GPH1148T5L/4P. It is commonly used in water treatment, air purification, and industrial UV curing systems where reliable lamp ignition and long lamp life are required.

What are the specifications of the Allanson 3G-OTH-03048?

The Allanson 3G-OTH-03048 operates at 24 VDC input voltage, draws 2.6 A, and delivers 60 W input power. It supports one lamp at 425 mA, with an operating frequency above 35 kHz, efficiency over 90%, and approvals including UL/cUL Listed, Class P. Dimensions are 9.47" x 2.29" x 1.67" and weight is 2.55 lb.

Where to buy the Allanson 3G-OTH-03048 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03048 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this program-start ballast. We source genuine Allanson components for industrial applications.

How to install the Allanson 3G-OTH-03048 ballast?

Install the Allanson 3G-OTH-03048 by connecting the 24 VDC input to the correct polarity terminals per the wiring diagram. Mount the ballast in a dry, ventilated area with ambient temperature between 0-40 °C. Ensure the case temperature does not exceed 75 °C. Use only with compatible standard UV lamps listed in the datasheet.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T6-2100-48VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T6-1400-230V UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T5-800-MV UV Ballast – Instant Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start