We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

The FBR X GAS X2/2 CE TL is a two-stage gas burner designed for industrial heating applications, delivering thermal power from 21 to 80 Mcal/h with a maximum electrical input of 93 kW. Operating at IP 40 protection…

SKU 3G-FBR-00549

Also listed as: 00678531 · 006785 31 · 006785-31

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
11.5 kg
stage
2 stages
fuel type
Gas
nozzle mm
90
fan motor w
75
power kw max
93
power kw min
24.4
ip protection
IP 40
noisiness dba
61-62
gas consumption
2.5/4.1-9.4
electrical supply
1
power supply info
50Hz
current absorption a
0.55
thermal power mcal h
21/35-80
nominal electric power w
130
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES SK071055_B_en GAS BURNERS TWO STAGES GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE Gas burners two stages with: aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X4/2CE GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X1/2CE - GAS X2/2CE MODEL GAS X1/2CE GAS X2/2CE Thermal power min. - max. * [Mcal/h] 15.5/20-50 21/35-80 Thermal power min. - max. * [kW] 18/23.2-58.1 24.4/40.7-93 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.8/2.3-5.8 2.5/4.1-9.4 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.7/0.9-2.3 0.9/1.6-3.6 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - 14/28 Max. pressure at the entry of valves (Pe. max) [mbar] 60 360 Nominal electric power [W] 110 130 Fan motor [W] 75 75 Nominal motor current absorption [A] 0.55 0.55 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 60-61 61-62 Burner weight **** [kg] 11 11.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [mbar] 3 GAS X1/2 GAS X2/2 2 1 0 -1 0 50 100 [kW] 0 50 100 [Mcal/h] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X3/2CE - GAS X4/2CE MODEL GAS X3/2CE GAS X4/2CE Thermal power min. - max. * [Mcal/h] 30/60-150 55/100-200 Thermal power min. - max. * [kW] 34.9/69.8-174 64/116-232 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 3.5/7-17.4 6.4/11.6-23.2 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 1.3/2.7-6.5 2.5/4.5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 14/31 14/21 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 11/30 11/19 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 10/28 8/17 Max. pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [W] 200 226 Fan motor [W] 110 200 Nominal motor current absorption [A] 0.77 1.35 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 66-69 66-69 Burner weight **** [kg] 16 19 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). **** For burner with cover in steel (F) add 3 kg to the weight. [PEDU] 6 5 4 3 2 GAS X3/2 GAS X4/2 1 0 -1 0 50 100 150 200 250 [ kW ] 0 50 100 150 200 [Mcal/h] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X1/2CE - GAS X2/2CE - GAS X3/2CE - GAS X4/2CE - GAS X5/2CE GAS BURNERS TWO STAGES SK071055_B_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS X5/2CE MODEL GAS X5/2CE Thermal power min. - max. * [Mcal/h] 70/130-300 Thermal power min. - max. * [kW] 81.4/151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 8.2/15.2-35 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 3.2/5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 16/25 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 15/12 Max. pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W]…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR X GAS X2/2 CE TL is a two-stage gas burner designed for industrial heating applications, delivering thermal power from 21 to 80 Mcal/h with a maximum electrical input of 93 kW. Operating at IP 40 protection and 61–62 dBA, it suits medium to large-scale combustion installations.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR X GAS X2/2 CE TL burner in the Philippines?

3G Electric Philippines is an authorized distributor. We handle the full supply chain — order placement, Bureau of Customs documentation, and delivery to Manila, Quezon City, and CALABARZON regions. Lead time on request.

What is the thermal output range of the FBR X GAS X2/2 CE TL?

The burner delivers 21 Mcal/h at minimum and 80 Mcal/h at maximum. It operates in two stages with a maximum electrical input of 93 kW, making it suitable for medium to large-scale industrial heating.

Is the FBR X GAS X2/2 CE TL suitable for food processing plants?

Yes. Its two-stage combustion (21–80 Mcal/h), IP 40 protection, and low noise (61–62 dBA) make it ideal for food processing and packaging facilities. A 90 mm nozzle and 75 W fan motor ensure stable, efficient operation in industrial duty cycles.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X GAS X2/2 CE TC | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X2/2 CE TC | Variant: variant_2 | Subgroup: Burner
X GAS X1/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X1/2 CE TL | Variant: variant_2 | Subgroup: Burner
X GAS X1/2 CE TC | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X1/2 CE TC | Variant: variant_2 | Subgroup: Burner
X GAS X3/2 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X3/2 CE TL | Variant: variant_2 | Subgroup: Burner
X GAS X2/2 CE TL | Variant: metano | Subgroup: Burner
FBR
X GAS X2/2 CE TL | Variant: metano | Subgroup: Burner
GAS X2/2 CE-LX TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/2 CE-LX TL Cl. 4 | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL